Loading…
| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 19 Apr 2025 | Xmi Llc | lumber douglas fir | ulthbrklch9945 |
| 19 Apr 2025 | Brunswick Valley Lumber Inc | european framing lumber | ulthbrklch9841 |
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 07 Apr 2026 | Aarhus | No | 107111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required |
| 25 Feb 2026 | Onne | No | 0 |
| 27 Oct 2025 | Pohang |
| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 18 Oct 2025 |
| 19 Apr 2025 | Centurion Lumber Ltd | european lumber | ulthbrklch9842 |
| 19 Apr 2025 | Centurion Lumber Ltd | austrian whitewood | ulthbrklch9934 |
| 19 Apr 2025 | Mercer Timber Products Llc | pine spruce | ulthbrklch9882 |
| 19 Apr 2025 | Mercer Timber Products Llc | lumber (picea spp / pinus spp / abies spp) | ulthbrklch9941 |
| 19 Apr 2025 | Olympic Industries Ulc C/O Logistec Terminals Inc | lumber spruce | ulthbrklch9889 |
| 19 Apr 2025 | Olympic Industries Ulc C/O Logistec Terminals Inc | lumber austrian pine | ulthbrklch9922 |
| 19 Apr 2025 | Sitka Forest Products | lumber german spruce | ulthbrklch9873 |
| 15 Apr 2025 | Bruce Oakley Inc | 7030.150 mt granular ammonium sulphate | ulth250709000002 |
| 15 Apr 2025 | Oakley International Llc | 5450.000 mt granular ammonium sulphate | ulth250709000001 |
| No |
| 0 |
| 13 Jun 2025 | San Antonio | No | 2FIRE SAFETY (Fire Fighting Equipment And Appliances) (09.06.2025) No 2 18407 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Lighting (Working Spaces)) (09.06.2025) |
| 09 Jun 2025 | San Antonio | No | 21 07110 FIRE SAFETY (Fire Fighting Equipment And Appliances) No 2 18407 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Lighting (Working Spaces)) No |
| 15 May 2025 | Pisco | No | 0 |
| 06 Jan 2025 | Ho Chi Minh City | No | 21 14615 POLLUTION PREVENTION - MARPOL ANNEX VI (Fuel Change-Over Procedure) (13.11.2024) No 2 07103 FIRE SAFETY (Division - Decks,Bulkheads And Penetrations) (13.11.2024) No |
| 13 Nov 2024 | Shimizu | No | 31 14615 POLLUTION PREVENTION - MARPOL ANNEX VI (Fuel Change-Over Procedure) No 2 07103 FIRE SAFETY (Division - Decks,Bulkheads And Penetrations) No 3 01308 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Records Of Rest) No |
| 30 Aug 2024 | Gwangyang | No | 251 18416 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Ropes And Wires) (21.03.2024) No 2 10135 SAFETY OF NAVIGATION (Monitoring Of Voyage Or Passage Plan) (08.08.2023) No 3 18413 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Warning Notices) (21.03.2024) No 4 02108 STRUCTURAL CONDITIONS (Electrical Installations In General) (08.08.2023) No 5 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) (21.03.2024) No 6 18499 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Other (Health Protection, Medical Care...)) (21.03.2024) No 7 11124 LIFE SAVING APPLIANCES (Embarkation Arrangement Survival Craft) (08.08.2023) No 8 03199 WATER/WEATHERTIGHT CONDITIONS (Other (Load Lines)) (21.03.2024) No 9 03199 WATER/WEATHERTIGHT CONDITIONS (Other (Load Lines)) (21.03.2024) No 10 18418 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Winches & Capstans) (21.03.2024) No 11 18302 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Sanitary Facilities) (08.08.2023) No 12 18302 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Sanitary Facilities) (21.03.2024) No 13 18306 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Sleeping Room, Additional Spaces) (21.03.2024) No 14 18321 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Heating, Air Conditioning And Ventilation) (08.08.2023) No 15 18318 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Food Temperature) (21.03.2024) No 16 18312 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Galley, Handlingroom (Maintenance)) (08.08.2023) No 17 18408 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Electrical) (08.08.2023) No 18 18315 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Provisions Quality And Nutritional Value) (21.03.2024) No 19 15150 ISM (ISM) (08.08.2023) No 20 14599 POLLUTION PREVENTION - MARPOL ANNEX V (Other MARPOL Annex V) (21.03.2024) No 21 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) (21.03.2024) No 22 15150 ISM (ISM) (21.03.2024) No 23 14104 POLLUTION PREVENTION - MARPOL ANNEX I (Oil Filtering Equipment) (21.03.2024) No 24 13199 PROPULSION AND AUXILIARY MACHINERY (Other (Machinery)) (21.03.2024) No 25 18317 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Food Personal Hygiene) (21.03.2024) No |
| 21 Mar 2024 | Vancouver (Can) | No | 1718416 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Ropes And Wires) No 2 18413 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Warning Notices) No 3 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) No 4 18499 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Other (Health Protection, Medical Care...)) No 5 03199 WATER/WEATHERTIGHT CONDITIONS (Other (Load Lines)) No 6 03199 WATER/WEATHERTIGHT CONDITIONS (Other (Load Lines)) No 7 18418 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Winches & Capstans) No 8 18302 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Sanitary Facilities) No 9 18306 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Sleeping Room, Additional Spaces) No 10 18318 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Food Temperature) No 11 18315 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Provisions Quality And Nutritional Value) No 12 14599 POLLUTION PREVENTION - MARPOL ANNEX V (Other MARPOL Annex V) No 13 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) No 14 15150 ISM (ISM) No 15 14104 POLLUTION PREVENTION - MARPOL ANNEX I (Oil Filtering Equipment) No 16 13199 PROPULSION AND AUXILIARY MACHINERY (Other (Machinery)) No 17 18317 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Food Personal Hygiene) No |
| 12 Mar 2024 | San Pedro, California | No | 5System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07199 - Other (Fire Safety) Cause: Improper/Lack Of Maintenance Action: 10 - Deficiency Rectified Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: An Aggregate Of More Than 7.6 Liters (Two Gallons) Of Flammable Of Combustible Liquids Stowed Outside An Accommodation, Control, Or Service, Space (Other Than A Paint Locker) Or Outside Of A Machinery Space Must Be Stowed In A Paint Locker. PSCO Observed Several Gallons Of Miscellaneous Flammable Liquids Stored In Engine Room Void Space. 46 CFR 147.45(E) Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/12/2024 12:00:00 AM Resolution Description: Vessel Removed Miscellaneous Flammable Liquids Stored In Engine Room Void Space And Placed Them In Paint Locker. Corrected On The Spot. System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13199 - Other (Machinery) Cause: Invalid Action: 40 - Rectify Deficiencies Prior To Next US Port After Sailing Foreign Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Every Steam Pipe And Every Fitting Connected Thereto Through Which Steam May Pass Shall Be So Designed, Constructed And Installed As To Withstand The Maximum Working Stresses To Which It May Be Subjected. PSCO Observed Steam Line Leak In Purifier Room And On The Forward Engine Room Bulkhead Fuel Oil Line. 74 SOLAS (14) II-1/33.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/15/2024 12:00:00 AM Resolution Description: Vessel Provided Class Survey Attesting To The Successful Repair Of The Steam Line Leak, Stating "After Completion Of The Repair, Leakage Test Was Carried Out, And No Leakage Was Found." System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Invalid Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Machinery, Boilers, And Other Pressure Vessels, Associated Piping Systems And Fittings Shall Be Of A Design And Construction Adequate For The Service For Which They Are Intended And Shall Be So Installed And Protected As To Reduce To A Minimum Any Danger To Persons On Board, Due Regard Being Paid To Moving Parts, Hot Surfaces And Other Hazards. PSCO Observed Wasted Refractory Brick Inside Incinerator Door. 74 SOLAS (14) II-1/26.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/15/2024 12:00:00 AM Resolution Description: Vessel Provided Class Survey Attesting To The Successful Repair Of The Incinerator Brick, Stating "After Completion Of The Reformed, Visual Inspection Was Carried Out With Satisfactory Result." System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Machinery, Boilers, And Other Pressure Vessels, Associated Piping Systems And Fittings Shall Be Of A Design And Construction Adequate For The Service For Which They Are Intended. The Design Shall Have Regard To Materials Used In Construction, The Purpose For Which The Equipment Is Intended, The Working Conditions To Which It Will Be Subjected And The Environmental Conditions On Board. PSCO Observed Jacket Water And Hydraulic Line Leak On No. 2 Cylinder Of The Main Engine. 74 SOLAS (14) II-1/26.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/15/2024 12:00:00 AM Resolution Description: Vessel Provided Class Survey Attesting To The Successful Repair Of Jacket Water And Hydraulic Line Leak On No.2, Stating "After Completion Of The Replacement, Maine Engine Operation Test Was Carried Out With Satisfactory Result, And No Leakage Was Found." System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13102 - Auxiliary Engine Cause: Invalid Action: 40 - Rectify Deficiencies Prior To Next US Port After Sailing Foreign Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Of Flammable Liquids. For This Purpose, The Following Functional Requirements Shall Be Met: Means Shall Be Provided To Control Leaks Of Flammable Liquids. PSCO Observed A Leak Line On No. 2 Generator From A Suspected Mechanical Seal Failure. The Line Was Discharging Oily Water And Accumulating Under Nearby Desk Plates. 74 SOLAS (14) II-2/4.1.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/15/2024 12:00:00 AM Resolution Description: Vessel Provided Class Survey Attesting To The Successful Repair Of The Leak Line On The No.2 Generator, Stating "After Completion Of The Repair, Operation Test Was Carried Out With Satisfactory Result, And No Leakage Was Found." |
| 27 Sep 2023 | Kijang | No | 0 |
| 08 Aug 2023 | Fremantle, Wa | No | 12SAFETY OF NAVIGATION (Monitoring Of Voyage Or Passage Plan) No; 2 02108 STRUCTURAL CONDITIONS (Electrical Installations In General) ; 3 04117 EMERGENCY SYSTEMS (Functionality Of Safety Syste)No; 4 07113 FIRE SAFETY (Fire Pumps And Its Pipes) No; 5 11124 LIFE SAVING APPLIANCES (Embarkation Arrangement Survival Craft) No; 6 11123 LIFE SAVING APPLIANCES (Emergency Equipment For 2-Way Comm.) No; 7 18302 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Sanitary Facilities) No; 8 18314 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Provisions Quantity) No; 9 18321 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Heating, Air Conditioning And Ventilation); 10 18312 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Galley, Handlingroom (Maintenance)) No 11 18408 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Electrical) No; 12 15150 ISM (ISM) |
| 07 Aug 2023 | Fremantle, Wa | No | 11 01309 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Fire Control Plan - All) (17.11.2022) No |
| 17 Jul 2023 | Chittagong | No | 0 |
| 17 Nov 2022 | Otaru | No | 1CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Fire Control Plan - All) |
| $14.8M |
| Unknown |