Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 27 Apr 2025 | Lerwick | No | 503107, Doors, Water/Weathertight Conditions, 1026, Damaged,11131, On Board Training And Instructions, Life Saving Appliances, 1011, Not As Required,18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe,07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required,18316, Water, Pipes, Tanks, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1026, Damaged |
| 02 Jan 2025 | Texas City | No | 1System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07109 - Fixed Fire Extinguishing Installation Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: TWO SEPARATE CONTROLS SHALL BE PROVIDED FOR RELEASING CARBON DIOXIDE INTO A PROTECTED SPACE AND TO ENSURE THE ACTIVATION OF THE ALARM. ONE CONTROL SHALL BE USED FOR OPENING THE VALVE OF THE PIPING WHICH CONVEYS THE GAS INTO THE PROTECTED SPACE AND A SECOND CONTROL SHALL BE USED TO DISCHARGE THE GAS FROM ITS STORAGE CONTAINERS. PSCO OBSERVED THE SYSTEM'S PNEUMATIC RELEASE BALL VALVE ASSEMBLY (WHICH IS DIRECTLY CONNECTED TO VALVE 1) UNINSTALLED, HINDERING THE FIRST CONTROL FROM OPENING THE VALVE THAT SENDS CO2 INTO THE PROTECTED SPACE. CITE: 74 SOLAS (20)II-2 / 10.4.1.5 FSS CODE: CH. 5.2.2.2 Due Date: 1/16/2025 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/10/2025 12:00:00 AM Resolution Description: N/A |
| 28 Jun 2023 | Houma, Louisiana | No | 2System: 02 - Structural Conditions Sub-System: N/A - No Subsystem Cause: Invalid Description Of Deficiency: 02105- The Main Steering Gear And Rudder Stock Shall Be Capable Of The Rudder Over From 35 Degrees On One Side To 35 Degrees On The Other Side. Sta |
| 28 Jun 2023 | Houma, Louisiana | No | 0 |
| 06 Sep 2022 | Rotterdam | No | 410111, Charts, Safety Of Navigation, 1179, Not Updated, 14604, Bunker Delivery Notes, Pollution Prevention - Marpol Annex VI, 1011, Not As Required, 10116, Nautical Publications, Safety Of Navigation, 1000, Missing, 18327, Ventilation (Working Spaces), La |
| 31 Aug 2021 | Las Palmas De Gran Canaria | No | 114104, Oil Filtering Equipment, Pollution Prevention - Marpol Annex I, 1082, Inoperative, ,, 0 |