| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 26 Sep 2023 | Glacier Northwest Inc | ordinary portland cement in bulk type ii-v conforming to astm | WBPE0000815 |
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 30 Apr 2026 | Antwerpen | No | 1307105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required,11101, Lifeboats, Life Saving Appliances, 1086, Not Properly Maintained,04121, Crew Familiarization With Emergency Systems, Emergency Systems, 1011, Not As Required,10101, Pilot Ladders And Hoist/Pilot Transfer Arrangements, Safety Of Navigation, 1026, Damaged,04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required,14104, Oil Filtering Equipment, Pollution Prevention - Marpol Annex I, 1011, Not As Required,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative,07117, Jacketed High Pressure Lines And Oil Leakage Alarm, Fire Safety, 1082, Inoperative,07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required,13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,13104, Bilge Pumping Arrangements, Propulsion And Auxiliary Machinery, 1011, Not As Required,07125, Evaluation Of Crew Performance (Fire Drills), Fire Safety, 1208, Lack Of Familiarity,15150, ISM, ISM, 1011, Not As Required |
| 12 Feb 2026 | Aliaga | No | 0 |
| 09 Jan 2026 | New Orleans | No | 0 |
| 24 Jan 2025 | Port Of Dakar | No | 0 |
| 26 Dec 2024 | Belfast | No | 0 |
| 04 Nov 2024 | Houston | No | 5System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07109 - Fixed Fire Extinguishing Installation Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED CLOSED VALVE ON SUPPLY LINE OF LOCAL WATER MIST FIRE SUPPRESSION SYETEM, MAKING SYSTEM UNAVAILABLE FOR IMMEDIATE USE. 74 SOLAS (20) II-2/14.2.1.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 11/4/2024 12:00:00 AM Resolution Description: PSCO VERIFIED THE OPENING OF PREVIOUSLY CLOSED VALVE ON LOCAL WATER MIST FIRE SUPPRESSION SYSTEM. System: 15 - Safety Management Systems (ISM) Sub-System: N/A - No Subsystem Component: 15109 - Maintenance Of The Ship And Equipment Cause: Improper/Lack Of Maintenance Action: 705 - Other - As Specified Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: IN MEETING THESE REQUIREMENTS THE COMPANY SHOULD ENSURE THAT INSPECTIONS ARE HELD AT APPROPRIATE INTERVALS AND ANY NON-CONFORMITY IS REPORTED WITH ITS POSSIBLE CAUSE, IF KNOWN. PSCO OBSERVED MISSING QUARTERLY SAFETY INSPECTION, MONTHLY INSPECTION ITEMS RECORDED AS SATISFACTORY WHEN FOUND UNSATISFACTORY, AND ENGINE ROOM NON-CONFORMITIES NOT REPORTED TO COMPANY IN ACCORDANCE WITH SMS. AN INTERNAL ISM AUDIT REPORT WITH CORRECTIVE ACTIONS SATISFACTORY TO THE OCMI SHALL BE SUBMITTED WITHIN 90 DAYS. 74 SOLAS (20) IX/3.1 & ISM Code 10.2.1 + .2 Due Date: 2/2/2025 12:00:00 AM Deficiency Resolved? No Resolved Date: N/A Resolution Description: N/A System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Improper Installation Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: THE FOLLOWING FIRE PROTECTION SYSTEMS SHALL BE KEPT IN GOOD ORDER SO AS TO ENSURE THEIR REQUIRED PERFORMANCE IF A FIRE OCCURS. STRUCTURAL FIRE PROTECTION, INCLUDING FIRE-RESISTING DIVISIONS, AND PROTECTION OF OPENINGS AND PENETRATIONS IN THESE DIVISIONS. PSCO OBSERVED UNAUTHORIZED HOLDBACKS ON CLASS A SELF CLOSING FIRE DOORS FROM THE ENGINE ROOM TO STEERING GEAR AND TO THE ESCAPE TRUNK FROM THE ENGING ROOM FLOOR. 74 SOLAS (20) II-2/14.2.1.1.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 11/4/2024 12:00:00 AM Resolution Description: PSCO VERIFIED REMOVAL OF HOLDBACK MECHANISMS ON SELF CLOSING FIRE DOORS. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07106 - Fire Detection And Alarm System Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: THE FUNCTION OF FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS SHALL BE PERIODICALLY TESTED TO THE SATISFACTION OF THE ADMINISTRATION BY MEANS OF EQUIPMENT PRODUCING HOT AIR AT THE APPROPRIATE TEMPERATURE…OR OTHER PHENOMENA ASSOCIATED WITH INCIPIENT FIRES TO WHICH THE DETECTOR IS DESIGNED TO RESPOND. PSCO OBSERVED CREW USING A LASER POINTER TO TEST FLAME DETECTORS INSTEAD OF PROPER EQUIPMENT LISTED IN SHIP’S TESTING PROCEDURES. 74 SOLAS (04) II-2/7.3.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 11/7/2024 12:00:00 AM Resolution Description: ABS Surveyor Provide Report For Procurment And Testing Of New Sensor Testing Equipment. System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13199 - Other (Machinery) Cause: Improper/Lack Of Maintenance Action: 40 - Rectify Deficiencies Prior To Next US Port After Sailing Foreign Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES, AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE WORKING CONDITIONS TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITIONS ON BOARD. PSCO OBSERVED MULTIPLE LEAKS ON SEAWATER COOLING LINES AND TEMPORARY REPAIRS IN THE VICINITY OF PUMPS AND FRESH WATER COOLER. 74 SOLAS (04) II-1/26.1 Due Date: N/A Deficiency Resolved? No Resolved Date: N/A Resolution Description: N/A |
| 20 Nov 2023 | Kobe | No | 51 01214 CERTIFICATE AND DOCUMENTATION - CREW CERTIFICATES (Endorsement By Flagstate) No 2 14699 POLLUTION PREVENTION - MARPOL ANNEX VI (Other MARPOL Annex VI) No 3 06103 CARGO OPERATIONS INCLUDING EQUIPMENT (Other Cargo/Timber/Deck/Construction) No 4 04108 EMERGENCY SYSTEMS (Muster List) No 5 11101 LIFE SAVING APPLIANCES (Lifeboats) No |
| 28 Aug 2023 | Nghe An | No | 0 |
| 26 Jun 2023 | New Orleans | No | 0 |
| 08 Feb 2023 | Szczecin | No | 8Engine International Air Pollution Prev. Cert., Engine International Air Pollution Prev. Cert., Nautical Publications, Nautical Publications, Sewage Treatment Plant, Machinery Controls Alarm, Fire Detection And Alarm System, Water, Pipes, Tanks |
| 27 Jul 2022 | Tekirdag | No | 10Certificate & Documentation - Ship Certificates, 01124 - International Air Pollution Cert., Not Properly Filled Radio Communications, 05111 - Satellite EPIRB 406MHz/1.6GHz, Not As Required Life Saving Appliances, 11101 - Lifeboats, Missing Fire Safety, 07109 - Fixed Fire Extinguishing Installation, Not As Required Life Saving Appliances, 11131 - On Board Training And Instructions, Not As Required Fire Safety, 07111 - Personal Equipment For Fire Safety, Not As Required Fire Safety, 07110 - Fire Fighting Equipment And Appliances, Expired Alarms, 08107 - Machinery Controls Alarm, Inoperative Propulsion And Auxiliary Machinery, 13104 - Bilge Pumping Arrangements, Inoperative ISM, 15150 - ISM, Not As Required |
| 26 Jan 2022 | Antwerpen | No | 0 |