Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 21 Mar 2026 | Miami Beach | No | 5System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Component: 11104 - Rescue Boats Cause: Improper/Lack Of Maintenance Action: 15 - Rectify Deficiencies By Next Port Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: All Life-Saving Appliances And Arrangements Shall Comply With The Applicable Requirements Of The Code. PSCOs Observed An Issue With Both Rescue Boat'S Emergency Steering That Affected Operation. For Emergency Steering To Work There Is A Butterfly Nut That Needs To Be Removed For Proper Operation, And This Bolt/Nut Was Installed Upside-Down On Each Rescue Boat. 74 SOLAS 20 III/34 LSA Code 1.2.2.7 15ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/21/2026 12:00:00 AM Resolution Description: Verified Corrected During The Exam By PSCOs. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07120 - Means Of Escape Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Administration Shall Ensure That Such Lighting Or Photoluminescent Equipment Has Been Evaluated, Tested, And Applied In Accordance With The Fire Safety Systems Code. Any Required Low-Location Lighting Systems Shall Be Approved By The Administration. PSCOs Observed A Corridor More Than 2 Meters Wide Missing Low-Location Lighting On One Side IAW IMO A. 752 (18). 74 SOLAS 20 II-2/13.3.2.5.1 FSS Code 11.2.1 16ac Due Date: 4/4/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/21/2026 12:00:00 AM Resolution Description: Verified Corrected During The Exam By PSCOs. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07120 - Means Of Escape Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Means Of Escape, Including Stairways And Exits, Shall Be Marked By Lighting Or Photoluminescent Strip Indicators Placed Not More Than 300 Mm Above The Deck At All Points Of The Escape Route, Including Angles And Intersections. The Marking Must Enable Passengers/Crew To Identify The Routes Of Escape And Readily Identify The Escape Exits. PSCOs Observed Furniture And Equipment Blocking Low Location Lighting In The Hospital. 74 SOLAS 20 II-2/13.3.2.5.1 16ac Due Date: 4/4/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/21/2026 12:00:00 AM Resolution Description: Verified Corrected During The Exam By PSCOs. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Doors And Door Frames In "B" Class Divisions And Means Of Securing Them Shall Provide A Method Of Closure Which Shall Have Resistance To Fire Equivalent To That Of The Divisions. PSCOs Observed A Self Closing B15 Door Propped Open With A Wedge. 74 SOLAS 20 II-2/9.4.1.2.1 16ac Due Date: 4/4/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/21/2026 12:00:00 AM Resolution Description: Verified Corrected During The Exam By PSCOs. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Openings Shall Be Provided With Permanently Attached Means Of Closing Which Shall Be At Least As Effective For Resisting Fires As The Divisions In Which They Are Fitted. PSCOs Observed FD 5.2.08 Unable To Fully Close. 74 SOLAS 20 II-2/9.4.1.1.1 16ac Due Date: 4/4/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/21/2026 12:00:00 AM Resolution Description: Verified Corrected During The Exam By PSCOs. |
| 14 Oct 2025 | Miami Beach | No | 0 |
| 17 Jul 2025 | Split | No | 0 |