Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 10 Sep 2025 | Houston | No | 9System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Design Flaw Action: 30 - Ship Detained Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: "A" CLASS DIVISIONS ARE THOSE DIVISIONS FORMED BY BULKHEADS AND DECKS WHICH COMPLY WITH THE FOLLOWING: THEY SHALL BE CONSTRUCTED AS TO BE CAPABLE OF PREVENTING THE PASSAGE OF SMOKE AND FLAME. PSCO OBSERVED THREE DOORS THAT WERE NOT GAS TIGHT-THE CO2 ROOM DOOR AND TWO DOORS LEADING INTO THE ENGINE ROOM. AIRFLOW WAS DETECTED AROUND THE PERIMETER OF THE DOORS WHILE IN THE CLOSED POSITIONS. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/15/2025 12:00:00 AM Resolution Description: Vessel Changed Gaskets And Adjusted Doors. Received Class Report Stating The Same. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: A Transfer Is Considered To Begin When The Person In Charge...(I) Each Transfer Hose Has No Unrepaired Loose Covers, Kinds, Bulges, Soft Spots, Or Any Other Defect Which Would Permit The Discharge Of Oil Or Hazardous Material Through The Hose Material. PSCO Observed Soft Spot And/Or Temporary Repair On Cargo Hose Connected Between #1 Starboard And #6 Port Manifold. 33CFR156.120 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/16/2025 12:00:00 AM Resolution Description: Received Class Report Stating Cargo Hose Removed From Manifold And Will Be Discarded At Next Available Port. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: A TRANSFER IS CONSIDERED TO BEGIN WHEN THE PERSON IN CHARGE...NO PERSON SHALL CONDUCT AN OIL OR HAZARDOUS MATERIAL TRANSFER OPERATION UNLESS: (F) THE END OF EACH HOSE AND LOADING ARM THAT IS NOT CONNECTED FOR THE TRANSFER OF OIL OR HAZARDOUS MATERIAL IS BLANKED OFF. PSCO OBSERVED 02 HOSES NOT IN USE AND NOT BLANKED OFF ON DECK. 33 CFR 156.120 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/10/2025 12:00:00 AM Resolution Description: Crew Blanked Off 02 Hoses. System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Component: 09209 - Electrical Cause: Improper/Lack Of Maintenance Action: 40 - Rectify Deficiencies Prior To Next US Port After Sailing Foreign Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED A MODIFIED SWITCH IN THE AIR CONDITIONING FLAT WITH EXPOSED ELECTRICAL WIRING. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/15/2025 12:00:00 AM Resolution Description: Vessel Crew Rectified Electrical Wiring. Class Report Received Stating The Same. System: 15 - Safety Management Systems (ISM) Sub-System: N/A - No Subsystem Component: 15109 - Maintenance Of The Ship And Equipment Cause: Improper/Lack Of Maintenance Action: 30 - Ship Detained Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: IN MEETING THESE REQUIREMENTS, THE COMPANY SHOULD ENSURE THAT: INSPECTIONS ARE HELD AT APPROPRIATE INTERVALS; ANY NON-CONFORMITY IS REPORTED, WITH ITS POSSIBLE CAUSE, IF KNOWN; APPROPRIATE CORRECTIVE ACTION IS TAKEN; AND RECORDS OF THESE ACTIVITIES ARE MAINTAINED. THE TECHNICAL AND/OR OPERATIONAL NATURE OF DEFICIENCIES 02-06 PROVIDE OBJECTIVE EVIDENCE OF A SERIOUS FAILURE OF THE ISM CODE IMPLEMENTATION. AN EXTERNAL AUDIT REPORT SATISFACTORY TO THE OCMI MUST BE SUBMITTED PRIOR TO CLEARANCE OF THIS DEFICIENCY AND RELEASE FROM DETENTION. 74 SOLAS (20)IX/3.1, ISM 10.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/26/2025 12:00:00 AM Resolution Description: Class Society (Lloyd'S Register) Provided External Audit Results Satisfying Sector H-G'S Requirements To Clear The Deficiency. Audit Results Uploaded To Deficiency Documents. System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Component: 09224 - Stowage Of Cargo Cause: Improper/Lack Of Maintenance Action: 30 - Ship Detained Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: PROVISION SHALL BE MADE TO ENSURE THAT THE LIQUID HEAD IN ANY TANK DOES NOT EXCEED THE DESIGN HEAD OF THE TANK. PSCO OBSERVED CARGO TANKS 9 STARBOARD, 10 PORT, AND 10 STARBOARD ABOVE 98%, WITH 10 STARBOARD AT 99.8%, VISUALLY OBSERVED FROM CARGO CONTROL ROOM. OBSERVATION MADE POST OVERFLOW CASUALTY RESULTING IN CARGO RELEASE ONTO THE DECK VIA THE VAPOR LINE. 74SOLAS(01)VII/10.1,IBC 8.2.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/15/2025 12:00:00 AM Resolution Description: Vessel Transferred Cargo Into 5P. Class Report Received. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Improper/Lack Of Maintenance Action: 30 - Ship Detained Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: SHIPS CARRYING TOXIC OR FLAMMABLE PRODUCTS OR BOTH SHALL BE EQUIPPED WITH AT LEAST TWO INSTRUMENTS DESIGNED AND CALIBRATED FOR TESTING THE SPECIFIC VAPOURS IN QUESTION. PSCO OBSERVED THAT THE VESSEL DID NOT CARRY ANY INSTRUMENTS TO MEASURE TOXIC VAPORS OF VINYL ACETATE, A CARGO CURRENTLY LOADED ON-BOARD. 74 SOLAS (01)VII/10.1, IBC 13.2.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/15/2025 12:00:00 AM Resolution Description: Vessel Received Vacuum Tubes For Vinyl Acetate. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Improper/Lack Of Maintenance Action: 30 - Ship Detained Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED TEMPORARY REPAIRS AND PIPE CLAMPS IN 09 LOCATIONS ALONG THE VAPOR COLLECTION SYSTEM "C" LINE. 74 SOLAS (20)I/II(A),IBC 1.5.3.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/15/2025 12:00:00 AM Resolution Description: Cargo Is Prohibited By Vessel In The U.S. COC Revoked. Class Provided Report Stating "C" Line Is Isolated And Repairs Will Be Made At Next Port. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Conditions Of The Ship And It'S Equipment Shall Be Maintained To Conform With The Provisions Of The Code To Ensure That The Ship Will Remain Fit To Proceed To Sea Without Danger To The Ship Or Persons On Board Or Without Presenting An Unreasonable Threat Of Harm To The Marine Environment. PSCO Observed Cargo Dripping From The 8P Manifold Flange At A Rate Of 12 Drips Per Minute. 74SOLAS(20)VII/10.1 IBC Code 1.5.3.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/15/2025 12:00:00 AM Resolution Description: Vessel Crew Tightened Down Flange And Stopped Dripping. |
| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 16 Dec 2013 |
| 08 Jul 2025 | Houston | No | 0 |
| 16 Jun 2024 | Houston | No | 0 |
| 01 Nov 2023 | Corpus Christi | No | 0 |
| 21 Jun 2022 | Kingstown | No | 0 |
| $11.7M |
| — |