| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 20 May 2026 | Gdynia | No | 701124, International Air Pollution Cert., Certificate & Documentation - Ship Certificates, 1002, Entries Missing,14604, Bunker Delivery Notes, Pollution Prevention - Marpol Annex VI, 1000, Missing,02107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required,03103, Railing, Gangway, Walkway And Means For Safe Passage, Water/Weathertight Conditions, 1086, Not Properly Maintained,01220, Seafarers' Employment Agreement (SEA), Certificate & Documentation - Crew Certificates, 1011, Not As Required,18428, On Board Programme For The Prevention Of Occupational Injuries And Deaseases, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required |
| 14 Oct 2025 | Rizhao | No | 81 02108 STRUCTURAL CONDITIONS (Electrical Installations In General) No 2 07116 FIRE SAFETY (Ventilation ) No 3 14616 POLLUTION PREVENTION - MARPOL ANNEX VI (Alternative Arrangements (SOx)) No 4 14899 POLLUTION PREVENTION - BALLAST WATER (Other BWM) No 5 04118 EMERGENCY SYSTEMS (Enclosed Space Entry And Rescue Drills) No 6 11104 LIFE SAVING APPLIANCES (Rescue Boats) No 7 02109 STRUCTURAL CONDITIONS (Permanent Means Of Access) No 8 11112 LIFE SAVING APPLIANCES (Launching Arrangements For Survival Craft) No |
| 19 Jun 2025 | Tianjin | No | 21 05111 RADIO COMMUNICATIONS (Satellite EPIRB 406MHz/1.6GHz) (19.06.2025) No 2 03112 WATER/WEATHERTIGHT CONDITIONS (Scuppers, Inlets And Discharges) (19.06.2025) |
| 24 Jan 2025 | Arlington/Baltimore | No | 1System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07126 - Oil Accumulation In Engine Room Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Igintion Of Combustible Materials Or Flammable Liquids. For This Purpose, The Following Functional Requirements Shall Be Met: Means Shall Be Provided To Control Leaks Of Flammable Liquids. PSCO Found Oil Leaking On The #3 Auxiliary Engine From The Coupling Shaft. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 1/26/2025 12:00:00 AM Resolution Description: Received, Reviewed And Accepted Class Report. |
| 03 Dec 2024 | Gdynia | No | 813102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,01102, Cargo Ship Safety Construction (Including Exempt.), Certificate & Documentation - Ship Certificates, 1265, Survey Out Of Window,01123, Continuous Synopsis Record, Certificate & Documentation - Ship Certificates, 1000, Missing,05109, VHF Radio Installation, Radio Communications, 1082, Inoperative,14616, Alternative Arrangements (SOx), Pollution Prevention - Marpol Annex VI, 1011, Not As Required,13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,14501, Garbage Shipboard Handling, Pollution Prevention - Marpol Annex V, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required,0,0,0,0,0,0,0,0,0,0,0 |
| 26 Mar 2024 | Portsmouth, Virginia | No | 0 |
| 27 Dec 2023 | Koper | No | 4Certificate & Documentation - Ship Certificates - Continuous Synopsis Record Entries Missing ; Fire Safety - Fire Pumps And Its Pipes Not As Required ; Labour Conditions - Health Protection, Medical Care, Social Security - Dangerous Areas Not As Required |
| 23 Mar 2022 | Amsterdam | No | 0 |
| 04 Mar 2021 | Swinoujscie | No | 0 |