| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 18 Jun 2026 | Lavrion | No | 7Labour Conditions > Accommodation, Recreational Facilities, Food And Catering | Heating, Air Conditioning And Ventilation | Inoperative; Emergency Systems | Emergency Fire Pump And Its Pipes | Not As Required; Labour Conditions > Health Protection, Medical Care, Social Security | Personal Protective Equipment (PPE) | Missing; Labour Conditions > Accommodation, Recreational Facilities, Food And Catering | Messroom And Recreational Facilities | Not As Required; Propulsion And Auxiliary Machinery | Auxiliary Engine | Not As Required; Safety Of Navigation | Echo Sounder | Inoperative; ISM | ISM | Not As Required |
| Date | Type | Details |
|---|---|---|
| 12 Nov 2024 | Mechanical Fault | Reported technical failure at Iskenderun, Türkiye, Departure was canceled until repairs were completed, and the vessel resumed operations on 15 November. |
| 01 Apr 2026 | Chornomorsk | No | 0 |
| 08 Jan 2026 | Pivdennyi | No | 21 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) Rectify Deficiency Before Departure Deficiency Rectified 2 FIRE SAFETY (Fire Detection And Alarm System) Rectify Deficiency Before Departure Deficiency Rectified |
| 13 Nov 2025 | Chornomorsk | No | 0 |
| 12 Oct 2025 | Dumyat (Damietta) | No | 5Emergency Systems 04103 - Emergency, Lighting,Batteries And Switches Not As Required Certificate & Documentation - Crew Certificates 01215 - Application For Endorsement By Flagstate Missing Labour Conditions - Minimum Requirements For Seafarers 18102 - Night Working Not As Required Water/Weathertight Conditions 03107 - Doors Not Properly Maintained Life Saving Appliances 11117 - Lifebuoys Incl. Provision And Disposition Light Missing |
| 11 Jun 2025 | Pivdennyi | No | 21 LIFE SAVING APPLIANCES (Rescue Boat Inventory) Rectify Deficiency Before Departure Deficiency Rectified 2 FIRE SAFETY (Ready Availability Of Fire Fighting Equipment) Rectify Deficiency Before Departure Deficiency Rectified |
| 02 Jun 2025 | Nea Karvali | No | 402117, Decks - Corrosion, Structural Conditions, 1029, Corroded,13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,18416, Mooring Ropes/Lines And Wires, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1082, Inoperative |
| 16 Apr 2025 | Dumyat (Damietta) | No | 5Emergency Systems 04108 - Muster List Not Updated Certificate & Documentation - Crew Certificates 01215 - Application For Endorsement By Flagstate Missing Safety Of Navigation 10105 - Magnetic Compass Not As Required Propulsion And Auxiliary Machinery 13103 - Gauges,Thermometers, Etc Not Updated Safety Of Navigation 10138 - BNWAS Inoperative |
| 03 Jan 2025 | Chornomorsk | No | 0 |
| 02 Jan 2025 | Chornomorsk | No | 0 |
| 13 Nov 2024 | Iskenderun | No | 14Safety Of Navigation 10116 - Nautical Publications Expired Safety Of Navigation 10199 - Other (Navigation) Other Certificate & Documentation - Documents 01305 - Log-Books/Compulsory Entries Entries Missing Living And Working Conditions - Working Conditions 09223 - Gangway, Accommodation-Ladder Unsafe Safety Of Navigation 10137 - Long-Range Identification And Tracking System (LRIT) Missing Yes Fire Safety 07120 - Means Of Escape Unsafe Life Saving Appliances 11105 - Rescue Boat Inventory Incomplete Emergency Systems 04114 - Emergency Source Of Power - Emergency Generator Inoperative Yes Yes Fire Safety 07114 - Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces Not As Required Yes Fire Safety 07110 - Fire Fighting Equipment And Appliances Not As Required Yes Yes Emergency Systems 04102 - Emergency Fire Pump And Its Pipes Not Properly Maintained Structural Conditions 02105 - Steering Gear Not Properly Maintained Yes Living And Working Conditions - Working Conditions 09218 - Protection Machines/Parts Missing Equipment ISM 15150 - ISM Not As Required Yes Total 3 0 0 5 |
| 17 Apr 2024 | Istanbul | Yes | 9Pollution Prevention - Marpol Annex I 14101 - Control Of Discharge Not As Required Yes Life Saving Appliances 11104 - Rescue Boats Inoperative Yes Certificate & Documentation - Documents 01314 - SOPEP Missing Safety Of Navigation 10110 - Signalling Lamp Inoperative Safety Of Navigation 10109 - Lights, Shapes, Sound-Signals Damaged Fire Safety 07110 - Fire Fighting Equipment And Appliances Not As Required Water/Weathertight Conditions 03108 - Ventilators, Air Pipes, Casings Not As Required Fire Safety 07110 - Fire Fighting Equipment And Appliances Not As Required Living And Working Conditions - Living Conditions 09108 - Lighting (Accommodation) Missing Total 2 0 0 0 |
| 18 Nov 2022 | Tanjung Priok | No | 6LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Gangway, Accommodation-Ladder) ; LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Cleanliness) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Lighting (Working Spaces)) ; LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Pipes, Wires (Insulation)) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Cleanliness Of Engine Room) ; PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) |
| 12 Sep 2022 | Davao | No | 41 14501 POLLUTION PREVENTION - MARPOL ANNEX V (Garbage) No 2 14199 POLLUTION PREVENTION - MARPOL ANNEX I (Other (MARPOL Annex I)) No 3 10128 SAFETY OF NAVIGATION (Navigation Bridge Visibility) No 4 18416 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CAR |
| 05 Jun 2022 | Cebu | No | 4FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) ; FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) ; LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Cleanliness) ; LIVING AND WORKING CONDITIONS - WOR |
| 15 Mar 2022 | Iligan, Mindanao | No | 21 04103 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) No 2 07126 FIRE SAFETY (Oil Accumulation In Engine Room) No |
| 09 Jan 2022 | Batangas, Luzon | No | 0 |