| 28 Jul 2021 | Zeebrugge | Belgium | Follow-Up | Yes | 3101325, ACM Statement Of Compliance (Including Exemption), Certificate & Documentation - Documents, 1011, Not As Required, 18422, Asbestos Fibres, Labour Conditions - Health Protection, Medical Care, Social Security, 1276, Not Removed, 02133, Asbestos Containing Materials, Structural Conditions, 1276, Not Removed, Other, Other, Other, Other, Other, 05111, Satellite EPIRB 406MHz/1.6GHz, Radio Communications, 1011, Not As Required, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 11101, Lifeboats, Life Saving Appliances, 1086, Not Properly Maintained, 07111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required, 18418, Winches & Capstans, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18418, Winches & Capstans, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 03112, Scuppers, Inlets And Discharges, Water/Weathertight Conditions, 1011, Not As Required, 11125, Embarkation Arrangements Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1011, Not As Required, 02117, Decks - Corrosion, Structural Conditions, 1029, Corroded, 04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1011, Not As Required, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 07113, Fire Pumps And Its Pipes, Fire Safety, 1011, Not As Required, 10101, Pilot Ladders And Hoist/Pilot Transfer Arrangements, Safety Of Navigation, 1027, Unsafe, 18424, Steam Pipes, Pressure Pipes, Wires (Insulation), Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 02112, Hull - Corrosion, Structural Conditions, 1029, Corroded, 07101, Fire Prevention Structural Integrity, Fire Safety, 1011, Not As Required, 02119, Enhanced Survey Programme (ESP), Structural Conditions, 1031, Incomplete, 07106, Fire Detection And Alarm System, Fire Safety, 1082, Inoperative, 04117, Functionality Of Safety Systems, Emergency Systems, 1011, Not As Required, 07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative, 15150, ISM, ISM, 1011, Not As Required, 11101, Lifeboats, Life Saving Appliances, 1047, Not Ready For Use, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 11101, Lifeboats, Life Saving Appliances, 1051, Fire System Damaged, 04109, Fire Drills, Emergency Systems, 1091, Lack Of Training, 11101, Lifeboats, Life Saving Appliances, 1026, Damaged |