BoatDB
Vessel

AYA

IMO 9516557
CargoBuilt 2008Active
4,339
Gross tonnageA measure of the vessel's total internal volume (not its weight).
6,840
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2008
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9516557
MMSI
352001071
Call sign
3E2440
Flag
PA
Type
General Cargo
Length (LOA)
103.7 m
Beam
17.2 m
Home port
PANAMA

Ownership

Beneficial owner
Operator
Technical manager
Milestone Gemi Islet
Commercial manager
Class society
BV
Design DWT
6,443 t
Flag
Panama
Built
2008

Timeline

key events over the vessel's life
  1. Special survey
  2. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
Special survey
22 Dec 2028
IOPP issued
23 Jan 2024
IOPP expires
22 Dec 2028

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
15 Jan 2026NovorossiyskNo91 STRUCTURAL CONDITIONS (Bulkhead -Corrosion) (14.07.2025) Other (Specify) Deficiency Rectified 2 SAFETY OF NAVIGATION (Voyage Data Recorder (VDR)/Simplified Voyage Data Recorder(S-VDR)) (04.08.2025) Rectify Deficiency Before Departure Deficiency Rectified 3 FIRE SAFETY (Emergency Escape Breathing Device And Disposition) (04.08.2025) Rectify Deficiency Before Departure Deficiency Rectified 4 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) Rectify Deficiency Before Departure Deficiency Rectified 5 WATER/WEATHERTIGHT CONDITIONS (Cargo & Other Hatchways) Rectify Deficiency Within 14 Days 6 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Entry Dangerous Spaces) Rectify Deficiency At Next Port 7 SAFETY OF NAVIGATION (Navigation Records) Rectify Deficiency Before Departure Deficiency Rectified 8 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Before Departure Deficiency Rectified 9 PROPULSION AND AUXILIARY MACHINERY (Propulsion Main Engine) Rectify Deficiency Before Departure Deficiency Rectified
14 Jan 2026NovorossiyskNo91 STRUCTURAL CONDITIONS (Bulkhead -Corrosion) (14.07.2025) Other (Specify) Deficiency Rectified 2 SAFETY OF NAVIGATION (Voyage Data Recorder (VDR)/Simplified Voyage Data Recorder(S-VDR)) (04.08.2025) Rectify Deficiency Before Departure Deficiency Rectified 3 FIRE SAFETY (Emergency Escape Breathing Device And Disposition) (04.08.2025) Rectify Deficiency Before Departure Deficiency Rectified 4 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) Rectify Deficiency Before Departure Deficiency Rectified 5 WATER/WEATHERTIGHT CONDITIONS (Cargo & Other Hatchways) Rectify Deficiency Within 14 Days 6 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Entry Dangerous Spaces) Rectify Deficiency At Next Port 7 SAFETY OF NAVIGATION (Navigation Records) Rectify Deficiency Before Departure Deficiency Rectified 8 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Before Departure Deficiency Rectified 9 PROPULSION AND AUXILIARY MACHINERY (Propulsion Main Engine) Rectify Deficiency Before Departure Deficiency Rectified
01 Oct 2025AliagaNo3Certificate & Documentation - Documents 01320 - Garbage Record Book Missing Certificate & Documentation - Documents 01305 - Log-Books/Compulsory Entries Not Properly Filled Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required
04 Aug 2025ConstantaNo3Labour Conditions - Health Protection, Medical Care, Social Security 18425 - Access / Structural Features (Ship) Not As Required Fire Safety 07112 - Emergency Escape Breathing Device And Disposition Not Properly Stowed Safety Of Navigation 10114 - Voyage Data Recorder (VDR) / Simplified Voyage Data Recorder (S-VDR) Inoperative
04 Aug 2025ConstantaNo61 STRUCTURAL CONDITIONS (Bulkhead -Corrosion) (14.07.2025) Other (Specify) 2 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Mooring Ropes/Lines And Wires) (14.07.2025) Rectify Deficiency Before Departure Deficiency Rectified 3 EMERGENCY SYSTEMS (Emergency Towing Arrangements And Procedures) (14.07.2025) Rectify Deficiency Before Departure Deficiency Rectified 4 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship)) Other (Specify) Deficiency Rectified 5 SAFETY OF NAVIGATION (Voyage Data Recorder (VDR)/Simplified Voyage Data Recorder(S-VDR)) Rectify Deficiency Before Departure 6 FIRE SAFETY (Emergency Escape Breathing Device And Disposition) Rectify Deficiency Before Departure
14 Jul 2025ConstantaNo3Structural Conditions 02114 - Bulkhead -Corrosion Not As Required Labour Conditions - Health Protection, Medical Care, Social Security 18416 - Mooring Ropes/Lines And Wires Damaged Emergency Systems 04107 - Emergency Towing Arrangements And Procedures Not As Required
02 Jul 2025NovorossiyskNo51 FIRE SAFETY (Ventilation ) (29.11.2024) Rectify Deficiency At Next Port Deficiency Rectified 2 STRUCTURAL CONDITIONS (Decks - Corrosion) (29.11.2024) Rectify Deficiency Within 14 Days Deficiency Rectified 3 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) Rectify Deficiency Before Departure Deficiency Rectified 4 WATER/WEATHERTIGHT CONDITIONS (Scuppers, Inlets And Discharges) Rectify Deficiency Before Departure Deficiency Rectified 5 RADIO COMMUNICATIONS (Radio Log (Diary)) Other (Specify)
29 Nov 2024BatumiNo4LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) (10.04.2024) Rectify Deficiency At Next Port Deficiency Rectified 2 CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Tonnage Certificate) (10.04.2024) Rectify Deficiency At Next Port De
14 May 2024RijekaYes1307106, Fire Detection And Alarm System, Fire Safety, 1082, Inoperative,04109, Fire Drills, Emergency Systems, 1205, Lack Of Control,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1011, Not As Required,05110, Facilities For Reception Of Marine Safety Inform., Radio Communications, 1011, Not As Required,11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 1047, Not Ready For Use,01308, Records Of Seafarers' Daily Hours Of Work Or Rest, Certificate & Documentation - Documents, 1255, Incorrect Entries,01132, Tonnage Certificate, Certificate & Documentation - Ship Certificates, 1000, Missing,18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe,18407, Lighting (Working Spaces), Labour Conditions - Health Protection, Medical Care, Social Security, 1082, Inoperative,18414, Protection Machines/Parts, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,14105, Pumping, Piping And Discharge Arrangements, Pollution Prevention - Marpol Annex I, 1011, Not As Required,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required
10 Apr 2024NovorossiiskNo15LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Ropes And Wires) (12.10.2023) Rectify Deficiency Before Departure Deficiency Rectified 2 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Cleanliness Of Engine Room) (12.10.2023) Rectify Deficiency Before Departure Deficiency Rectified 3 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (12.10.2023) Rectify Deficiency Before Departure Deficiency Rectified 4 WATER/WEATHERTIGHT CONDITIONS (Covers (Hatchway-, Portable-, Tarpaulins, Etc.)) (12.10.2023) Other (Specify) Deficiency Rectified 5 SAFETY OF NAVIGATION (Voyage Or Passage Plan) (12.10.2023) Rectify Deficiency Before Departure Deficiency Rectified 6 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) (12.10.2023) Rectify Deficiency Before Departure Deficiency Rectified 7 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Signs, Indications) (12.10.2023) Rectify Deficiency Before Departure Deficiency Rectified 8 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) (12.10.2023) Rectify Deficiency Within 14 Days Deficiency Rectified 9 ISM (ISM) (12.10.2023) Corrective Action Taken On The ISM System By The Company Is Required Within 3 Months Deficiency Rectified 10 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) Rectify Deficiency At Next Port 11 LIFE SAVING APPLIANCES (Inflatable Liferafts) Rectify Deficiency Before Departure Deficiency Rectified 12 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Before Departure Deficiency Rectified 13 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship)) Rectify Deficiency Before Departure Deficiency Rectified 14 FIRE SAFETY (Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces) Rectify Deficiency Before Departure Deficiency Rectified 15 CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Tonnage Certificate) Rectify Deficiency At Next Port
18 Feb 2024HaifaNo16Fire Safety 07109 - Fixed Fire Extinguishing Installation Inoperative Yes Fire Safety 07109 - Fixed Fire Extinguishing Installation Inoperative Yes Certificate & Documentation - Documents 01315 - Oil Record Book Not As Required Yes Emergency Systems 04102 - Emergency Fire Pump And Its Pipes Insufficient Pressure Yes Fire Safety 07113 - Fire Pumps And Its Pipes Insufficient Pressure Yes Fire Safety 07108 - Ready Availability Of Fire Fighting Equipment Inoperative Alarms 08199 - Other (Alarms) Other Fire Safety 07114 - Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces Inoperative Yes Fire Safety 07106 - Fire Detection And Alarm System Inoperative Living And Working Conditions - Working Conditions 09232 - Cleanliness Of Engine Room Insufficient Safety Of Navigation 10199 - Other (Navigation) Other Emergency Systems 04117 - Functionality Of Safety Systems Unsafe Yes Living And Working Conditions - Working Conditions 09209 - Electrical Unsafe Living And Working Conditions - Working Conditions 09209 - Electrical Not As Required Pollution Prevention - Marpol Annex I 14104 - Oil Filtering Equipment Inoperative ISM 15150 - ISM Not As Required Yes Total 0 0 0 8
12 Oct 2023AgigeaNo9Ropes And Wires, Auxiliary Engine, Cleanliness Of Engine Room, Voyage Or Passage Plan, Gauges,Thermometers, Etc, Covers (Hatchway-, Portable-, Tarpaulins, Etc.), Signs, Indications, Ventilators, Air Pipes, Casings, ISM
26 Mar 2023HaifaNo1Certificate & Documentation - Documents 01315 - Oil Record Book Not Properly Filled
15 Mar 2023NovorossiiskNo51 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship))2 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Lighting (Accommodation))3 LIFE SAVING APPLIANCES (Stowage And Provision Of Lifeboats)4 EMERGENCY SYSTEMS (Water Level Indicator)5 FIRE SAFETY (Ventilation )
05 May 2022RavennaYes2902117, Decks - Corrosion, Structural Conditions, 1029, Corroded, 11110, Stowage And Provision Of Liferafts, Life Saving Appliances, 1086, Not Properly Maintained, 18326, Laundry, Adequate Locker, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 02109, Permanent Means Of Access, Structural Conditions, 1027, Unsafe, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 14402, Sewage Treatment Plant, Pollution Prevention - Marpol Annex IV, 1011, Not As Required, 11124, Embarkation Arrangement Survival Craft, Life Saving Appliances, 1086, Not Properly Maintained, 02118, Decks - Cracking, Structural Conditions, 1070, Broken, 13106, Insulation Wetted Through (Oil), Propulsion And Auxiliary Machinery, 1026, Damaged, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required, 18312, Galley, Handlingroom (Maintenance), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1025, Not Hygienic, 18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 01308, Records Of Seafarers' Daily Hours Of Work Or Rest, Certificate & Documentation - Documents, 1255, Incorrect Entries, 10128, Navigation Bridge Visibility, Safety Of Navigation, 1011, Not As Required, 10105, Magnetic Compass, Safety Of Navigation, 1011, Not As Required, 10114, Voyage Data Recorder (VDR) / Simplified Voyage Data Recorder (S-VDR), Safety Of Navigation, 1011, Not As Required, 04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1082, Inoperative, 18418, Winches & Capstans, Labour Conditions - Health Protection, Medical Care, Social Security, 1086, Not Properly Maintained, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 07116, Ventilation, Fire Safety, 1011, Not As Required, 03104, Cargo & Other Hatchways, Water/Weathertight Conditions, 1026, Damaged, 03112, Scuppers, Inlets And Discharges, Water/Weathertight Conditions, 1011, Not As Required, 04108, Muster List, Emergency Systems, 1031, Incomplete, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 07101, Fire Prevention Structural Integrity, Fire Safety, 1011, Not As Required
30 Apr 2022Laurium (Lavrion)No402117, Decks - Corrosion, Structural Conditions, 1029, Corroded, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 03108, Ventilators, Air Pipes, Casings, Water/Weathertight Conditions, 10
07 Apr 2022KocaeliNo1Living And Working Conditions - Working Conditions, 09223 - Gangway, Accommodation-Ladder, Unsafe