Vessel
BALEEN
IMO 9855367
CargoBuilt 2020Active
54,043
Gross tonnageA measure of the vessel's total internal volume (not its weight).
82,374
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
—
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2020
Year built
Live position & voyage
LIVELoading position…
Shipments over time
bills of lading per monthParticulars
- IMO
- 9855367
- MMSI
- 538008771
- Call sign
- V7A2740
- Flag
- MH
- Type
- Bulk Carrier
- Length (LOA)
- 228.36 m
- Beam
- 34.59 m
- Home port
- —
Ownership
- Beneficial owner
- —
- Operator
- Klaveness Ship Management· Norway
- Technical manager
- Klaveness Ship Management
- Commercial manager
- Klaveness Ship Management
- Class society
- DNV
- Design DWT
- 82,374 t
- Flag
- Marshall Islands
- Built
- 2020
Timeline
key events over the vessel's life- Special survey
- Dry dock
- Built
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- 03 Aug 2028
- Special survey
- 04 Aug 2030
- IOPP issued
- 03 Aug 2025
- IOPP expires
- 04 Aug 2030
Top importers served
importers this vessel carried forShipments carried
recent bills of ladingInspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 15 Mar 2026 | Houston | No | 5System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06105 - Atmosphere Testing Instruments Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Audible And Visual Alarms Are To Be Initiated In The Cargo Control Room, Navigation Bridge And At The Analyzing Unit When Vapor Concentration In A Given Space Reaches A Pre-Set Value, Which Shall Not Be Higher Than The Equivalent Of 30% Of The Lower Flammable Limit. PSCO Observed The Crew Unable To Demonstrate An Alarm Above 5% LEL From Any Sample Point Tested. 74 Solas 20 II-2/4.5.7.3.1 FSS 16.2.2.3.3 Due Date: 3/15/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/16/2026 12:00:00 AM Resolution Description: Submitted Class Report And Videos Demonstrating Proper Operation Of The Fixed Gas Detection Cabinet. |
| 14 Apr 2025 | Quang Ninh | No | 0 |
| 02 Nov 2024 | Staten Island, New York | No | 0 |
| 22 Mar 2024 | Amsterdam | No | 0 |
| 31 Jul 2023 | New York | No | 0 |
| 09 May 2022 | Bunbury, WA | No | 2EMERGENCY SYSTEMS (Abandon Ship Drills) (20.04.2022); SAFETY OF NAVIGATION (Pilot Ladders And Hoist/Pilot Transfer Arrangements) (20.04.2022) |
| 22 Apr 2022 | Gladstone, Qld | No | 31 04110 EMERGENCY SYSTEMS (Abandon Ship Drills) No 2 14199 POLLUTION PREVENTION - MARPOL ANNEX I (Other (MARPOL Annex I)) No 3 10101 SAFETY OF NAVIGATION (Pilot Ladders And Hoist/Pilot Transfer Arrangements) No |
| 20 Apr 2022 | Gladstone, Qld | No | 41 04110 EMERGENCY SYSTEMS (Abandon Ship Drills) No 2 14199 POLLUTION PREVENTION - MARPOL ANNEX I (Other (MARPOL Annex I)) No 3 14108 POLLUTION PREVENTION - MARPOL ANNEX I (15 PPM Alarm Arrangmts.) No 4 10101 SAFETY OF NAVIGATION (Pilot Ladders And Hoist/P |
| 04 Oct 2021 | Rotterdam | No | 414804, Ballast Water Exchange, Pollution Prevention - Ballast Water, 1011, Not As Required, 11119, Immersion Suits, Life Saving Appliances, 1011, Not As Required, 02103, Stability/Strength/Loading Information And Instruments, Structural Conditions, 1011, |