Loading…
| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 30 Jul 2023 | Bbc Chartering Usa Llc | stc steel platforms ship equipment | bbhy1270033ab01a |
| 30 Jul 2023 | Gulf Stream Marine Inc | stc mobile harbour cranes | bbhy1270033ab01 |
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 11 Dec 2025 | Esbjerg | No | 2Labour Conditions - Accommodation, Recreational Facilities, Food And Catering 18312 - Galley, Handlingroom (Maintenance) Not Hygienic Structural Conditions 02101 - Closing Devices/Watertight Doors Damaged |
| 20 Oct 2025 | Shanghai | No |
| 30 Jul 2023 | Wartisle Finland Oy Energy | stc generators foreign retained on board cargo manifest thruthe first us port cargo to discharge in alta mira, mexico | bbhy1270033ba01 |
| 03 Nov 2021 | Tpi China Llc | total pkgs: packages: 596 total pkgs: packages: 596 total pkgs: packages: 596 | dsvfmaa8063561 |
| 15 Aug 2021 | Bbc Chartering Usa Llc | stc 400 x lashing chains 400 x lever 500 x d-rings sets ships equipment | bbhy270022tg01a |
| 15 Aug 2021 | Tpi China Llc | total pkgs: packages: 48 total pkgs: packages: 48 total pkgs: packages: 48 | dsvfmaa8059996 |
| 15 Aug 2021 | Tpi China Llc | total pkgs: packages: 628 total pkgs: packages: 628 total pkgs: packages: 628 | dsvfmaa8060086 |
| 27 Apr 2021 | Baker Hughes Enery Services Llc | stc partial shipment towards po number incl. box and seaworthy packing | bbhy1270021kc03 |
| 27 Apr 2021 | Lm | stc root end frames tip end frame (package material for windmill blade) lm622 rotor blade frames | bbhy1270021kc01 |
| 27 Apr 2021 | Lm | stc frp rotor blade wind turbine blade loaded on root end frame and tip frame | bbhy1270021kc02 |
| 15 Aug 2024 | Batangas, Luzon | No | 21 01315 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Oil Record Book) No 2 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) No |
| 18 May 2024 | Philadelphia | No | 5System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07126 - Oil Accumulation In Engine Room Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: A Ship In Which F/O Is Used, The Arrangement For Storage, Distribution, And Utilization Of The Fuel Oil Shall Ensure The Safety Of Ship And Persons Onboard. PSCO Observed Active Diesel Oil Leak On Bunker Supply Line Valve In E.R. Leak Was Contained In A ZOL Bucket Which Was Actively Overflowing In Bilge. 74SOLAS(20) II-2/4.2.2 Due Date: 6/1/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 6/3/2024 12:00:00 AM Resolution Description: Received Class Report Attesting To Replacement Of The FTV41 Valve On The Fuel Oil Transfer And Bunkering System. Pressure Test Carried Out By Crew On 21MAY24 With Satisfactory Result. During Class Attendance, No Oil Leaks Were Observed. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07108 - Ready Availability Of Fire Fighting Equipment Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Firefighting Systems And Appliances Shall Be Kept In Good Working Order And Readily Available For Immediate Use. PSCO Identified Fixed CO2 Nozzle Beside L.O Tank In The Engine Room Covered In Tape. Tape Was Removed On The Spot. 74SOLAS(20) II-2/4.2.1.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 5/18/2024 12:00:00 AM Resolution Description: Tape Removed From CO2 Nozzle. System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13199 - Other (Machinery) Cause: Action: 10 - Deficiency Rectified Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Hydraulic Operated Steering Gear Shall Be Provided With The Following Arrangements To Maintain The Cleanliness Of Fluid Taking Into Account The Type And Design Of System. PSCO Found Leaks Around Hydraulic Tank And Pooled Fluid On Deck. Crew Had Removed Fill Pipe Cape And Modified Piping Arrangements Resulting In Spilled Fluid On Deck. 74SOLAS(04) II-1/29.12.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 6/3/2024 12:00:00 AM Resolution Description: Crew Reinstalled Cap And Cleaned Fluid From Deck. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07199 - Other (Fire Safety) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Of Flammable Liquids; The Ignitability Of Combustible Materials Shall Be Restricted. PSCO Observed 20-30 Cardboard Pieces Stored On E.R. Deck Besides Active Diesel Oil Leak. Additionally, PSCO Observed Several Oil Soaked Rags Stuffed Throughout E.R. And Purifier Flat. 74SOLAS (20) II-2/4.1.3 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 5/18/2024 12:00:00 AM Resolution Description: Cardboard Pieces And Rags Removed. System: 04 - Emergency Systems Sub-System: N/A - No Subsystem Component: 04114 - Emergency Source Of Power - Emergency Generator Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Where The Emergency Source Of Electrical Power Is A Generator, It Shall Be Started Automatically Upon Failure Of Man Source Of Electrical Power Supply. The E-Gen Was Found In Manual Mode And Has Been In Position Since Last Test Date 27Apr2024. 74Solas(04) 11-1/43.3.1.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 5/18/2024 12:00:00 AM Resolution Description: E-Gen Was Position Was Set To Automatic. |
| 06 May 2024 | Port-Cartier | No | 710101, Pilot Ladders And Hoist/Pilot Transfer Arrangements, Safety Of Navigation, 1000, Missing,02109, Permanent Means Of Access, Structural Conditions, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required,18429, Procedure For Inspection, Reporting And Correcting Unsafe Conditions And For Investigating And Reporting On-Board Occupational Accidents, Labour Conditions - Health Protection, Medical Care, Social Security, 1000, Missing,11124, Embarkation Arrangement Survival Craft, Life Saving Appliances, 1086, Not Properly Maintained,99101, Other Safety In General, Other, 1238, Other,03105, Covers (Hatchway-, Portable-, Tarpaulins, Etc.), Water/Weathertight Conditions, 1011, Not As Required |
| 06 May 2024 | Port-Cartier | No | 0 |
| 08 Sep 2023 | Valparaiso | No | 1SAFETY OF NAVIGATION (Pilot Ladders And Hoist/Pilot Transfer Arrangements) (06.09.2023) |
| 07 Sep 2023 | Valparaiso | No | 41 18425 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship)) No 2 10101 SAFETY OF NAVIGATION (Pilot Ladders And Hoist/Pilot Transfer Arrangements) No 3 18312 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL |
| 06 Sep 2023 | Valparaiso | No | 41 18425 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship)) No 2 10101 SAFETY OF NAVIGATION (Pilot Ladders And Hoist/Pilot Transfer Arrangements) No 3 18312 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL |
| 31 Aug 2023 | Chancay | No | 0 |
| 05 May 2023 | Bremenhaven | No | 9Garbage Management Plan Not As Required ; Fire-Dampers Inoperative ; Winches & Capstans Not As Required ; Cargo & Other Hatchways Damaged ; Doors Damaged ; Openings To Cargo Area, Doors, ... Scuttles Not As Required ; Ventilators, Air Pipes, Casings Not As Required ; Emergency, Lighting,Batteries And Switches Not As Required ; ISM Not As Required |
| 04 Aug 2022 | Humen | No | 0 |
| 17 Jan 2022 | Amsterdam | No | 501221, Record Of Employment, Certificate & Documentation - Crew Certificates, 1003, Not Properly Filled, 18202, Legal Documentation On Work And Rest Hours, Labour Conditions - Conditions Of Employment, 1011, Not As Required, 15150, ISM, ISM, 1011, Not As Required, 08108, UMS - Alarms, Alarms, 1075, Inadequate, 18420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, |
| 12 Jan 2021 | Marsaxlokk | No | 302101, Closing Devices/Watertight Doors, Structural Conditions, 1026, Damaged, 07118, International Shore-Connection, Fire Safety, 1011, Not As Required, 07111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required, , 0 |