Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 24 Feb 2026 | Cuxhaven | No | 8Propulsion And Auxiliary Machinery 13103 - Gauges,Thermometers, Etc Not As Required Propulsion And Auxiliary Machinery 13101 - Propulsion Main Engine Not As Required Propulsion And Auxiliary Machinery 13104 - Bilge Pumping Arrangements Inoperative Propulsion And Auxiliary Machinery 13101 - Propulsion Main Engine Not As Required Life Saving Appliances 11101 - Lifeboats Damaged Water/Weathertight Conditions 03104 - Cargo & Other Hatchways Damaged Structural Conditions 02140 - Towing And Mooring Equipment Not As Required Safety Of Navigation 10103 - Radar Insufficient |
| Date | Type | Details |
|---|---|---|
| 18 Sep 2024 | Fire | An engine room explosion occurred while the vessel was 490 NM off the Isles of Scilly, resulting in the death of the second engineer. After repairs to the main engines, the vessel continued its voyage toward Montoir, France, on 19 September. |
| BBHY1015089HH01 |
| 23 May 2025 | Unknown | xt-710-oxo distillation train 1 stabilizing tower xt-740-oxo distillation train 1 fractionator tower xt-710 - liquid damper loose and spare parts | DMALANRB42090 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 1507 pcs american wide flange beams | BBHY1015080PH08 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 272 pcs american wide flange beams | BBHY1015080PH09 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 7 pcs american wide flange beams | BBHY1015080PH05 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 334 x bundles stc 2,555 pcs american wide flange beams 9 x bundles stc 150 pcs american wide flange beams | BBHY1015080PH11 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 112 pcs american wide flange beams | BBHY1015080PH02 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 92 pcs american wide flange beams | BBHY1015080PH04 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 112 pcs american wide flange beams | BBHY1015080PH03 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 199 x bundles stc 929 american wide flange beams 1 x bundles stc 12 american wide flange beams | BBHY1015080PH07 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 692 pcs american wide flange beams | BBHY1015080PH14 |
| 25 Mar 2025 | Arcelormittal International Americ | stc 125 pcs american wide flange beams | BBHY1015080PH06 |
| 27 Nov 2025 | Brisbane | No | 11 01328 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Ship Energy Efficiency Management Plan) (02.10.2025) |
| 02 Oct 2025 | Masan | No | 21 01328 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Ship Energy Efficiency Management Plan) No 2 14802 POLLUTION PREVENTION - BALLAST WATER (Ballast Water Record Book) No |
| 27 Mar 2025 | Houston | No | 1System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07126 - Oil Accumulation In Engine Room Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: THe Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Or Flammable Liquids. For This Purpose, The Following Functional Requirements Shall Be Met: Means Shall Be Provided To Control Leaks Of Flammable Liquids. PSCO Observed 02 Oil Leaks In The Purifier Flats And Oil Accumulation In The Bilges. 74 SOLAS (04) II-2/4.1.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/29/2025 12:00:00 AM Resolution Description: Class Report Submitted That Issue Was Resolved. |
| 28 Feb 2025 | Nantes | No | 2Fire-Dampers Inoperative ; Cleanliness Of Engine Room Not As Required |
| 09 May 2024 | Bintulu, Sarawak | No | 0 |
| 23 Oct 2023 | Fremantle, Wa | No | 2OTHER (Other Safety In General); LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Other (Accommodation, Recreational Facilities…)) |
| 21 Aug 2023 | Hamburg | No | 7Fire Safety; 07115 - Fire-Dampers; Not As Required; ISM; 15150 - ISM; Not As Required; Life Saving Appliances; 11113 - Launching Arrangements For Rescue Boats; Not Properly Maintained; Emergency Systems; 04103 - Emergency, Lighting,Batteries And Switches; Not As Required; Water/Weathertight Conditions; 03107 - Doors; Not Properly Maintained; Labour Conditions - Health Protection, Medical Care, Social Security; 18414 - Protection Machines/Parts; Damaged; Propulsion And Auxiliary Machinery; 13103 - Gauges,Thermometers, Etc; Not As Required |
| 14 Aug 2023 | Miami Beach, Florida | No | 0 |
| 23 May 2023 | Batangas, Luzon | No | 0 |
| 11 Jun 2022 | Sathahip | No | 0 |
| 01 Apr 2022 | Port-Alfred | No | 602136, Hull – Construction, Structural Conditions, 1011, Not As Required, 10118, Speed And Distance Indicator, Safety Of Navigation, 1082, Inoperative, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 11107, Stowage Of Rescue Boats, Life Saving Appliances, 1011, Not As Required, 18321, Heating, Air Conditioning And Ventilation, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 06199, Other (Cargo), Cargo Operations Including Equipment, 1238, Other, |
| 05 Mar 2021 | Antwerpen | No | 410118, Speed And Distance Indicator, Safety Of Navigation, 1082, Inoperative, 10101, Pilot Ladders And Hoist/Pilot Transfer Arrangements, Safety Of Navigation, 1026, Damaged, 07111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required, 1 |