BoatDB
Vessel

BENTLEY

IMO 9847891
CargoBuilt 2019Active
44,000
Gross tonnageA measure of the vessel's total internal volume (not its weight).
82,000
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2019
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9847891
MMSI
538012794
Call sign
V7B3339
Flag
MH
Type
Bulk Carrier
Length (LOA)
229 m
Beam
32.3 m
Home port

Ownership

Beneficial owner
Operator
Technical manager
Commercial manager
Class society
LR
Design DWT
82,000 t
Flag
Liberia
Built
2019

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
22 Jul 2027
Special survey
29 Sep 2029
IOPP issued
23 Jul 2024
IOPP expires
29 Sep 2029

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
25 Oct 2025NewcastleNo1POLLUTION PREVENTION - MARPOL ANNEX VI (Record Book Of Engine Parameters) (13.08.2025)
24 Oct 2025NewcastleNo4FIRE SAFETY (Other (Fire Safety)) No 2 10104 SAFETY OF NAVIGATION (Gyro Compass) No 3 02134 STRUCTURAL CONDITIONS (Loading/Ballast Condition) No 4 10135 SAFETY OF NAVIGATION (Monitoring Of Voyage Or Passage Plan)
13 Aug 2025YokohamaNo1POLLUTION PREVENTION - MARPOL ANNEX I (15 PPM Alarm Arrangmts.) (31.03.2025)
13 Aug 2025YokohamaNo51 02108 STRUCTURAL CONDITIONS (Electrical Installations In General) No 2 04103 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) No 3 11104 LIFE SAVING APPLIANCES (Rescue Boats) No 4 14602 POLLUTION PREVENTION - MARPOL ANNEX VI (Record Book Of Engine Parameters) No 5 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) No
31 Mar 2025DalianNo3POLLUTION PREVENTION - MARPOL ANNEX I (15 PPM Alarm Arrangmts.) No 2 07199 FIRE SAFETY (Other (Fire Safety)) No 3 18415 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Entry Dangerous Spaces)
10 Oct 2024CuxhavenNo1002108, Electrical Installations In General, Structural Conditions, 1027, Unsafe,04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1082, Inoperative,08109, Boiler Alarm, Alarms, 1100, Malfunctioning,03107, Doors, Water/Weathertight Conditions, 1086, Not Properly Maintained,07115, Fire-Dampers, Fire Safety, 1011, Not As Required,18424, Steam Pipes, Pressure Pipes, Wires (Insulation), Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe,13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,07122, Fire Control Plan, Fire Safety, 1112, Wrong Information,15150, ISM, ISM, 1011, Not As Required,,,,,,
17 Jun 2024BontangNo0
06 Feb 2023Kota BaruNo0