Loading…
| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 16 Mar 2026 | Suwannee American Co | ,. mt ggbfs in bulk | cgzvbes01cmpmnt1 |
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 04 Jun 2026 | Yali Island | No | 0 |
| 19 Mar 2026 | Florida | No | 1System: 02 - Structural Conditions Sub-System: N/A - No Subsystem Component: 02199 - Other (Structural Condition) Cause: Damaged By Earlier Event Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Efficient Guard Rails On Bulwarks Shall Be Fitted To All Exposed Parts Of The Free Board And Super Structure Decks. The Height Of The Bulwarks Or Guard Rails Shall Be At Least 1m (39.5 Inches) From The Deck. PSCO Observed The Guard Rail On The STBD Side Weather Deck In The Vicinity Of Cargo Hold #3 Bent And Not Meeting The Required Height, Measured 36 Inches. ICLL 1966 I/25.2/Bc Due Date: 4/18/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/19/2026 12:00:00 AM Resolution Description: The Deficiency Was Corrected By The Crew, And The Guardrail Section Is Now In Compliance With The Required Height. |
| Date | Type | Details |
|---|---|---|
| 11 May 2022 | Other | Vessel allegedly polluted the port of Derince, Turkey with dirty ballast water.The local authority opened an investigation and found the vessel guilty of the pollution. The vessel’s departure permission was cancelled by the Harbour Master until payment of the fine together with the cleaning expenses. |
| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 02 Oct 2024 |
| 12 Jan 2026 | Quang Ninh | No | 1STRUCTURAL CONDITIONS (Towing And Mooring Equipment) (20.10.2025) |
| 12 Jan 2026 | Quang Ninh | No | 0 |
| 22 Oct 2025 | Jiangyin | No | 51 07115 FIRE SAFETY (Fire-Dampers) (20.10.2025) No 2 03103 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) (20.10.2025) No 3 07109 FIRE SAFETY (Fixed Fire Extinguishing Installation) (20.10.2025) No 4 07101 FIRE SAFETY (Fire Prevention Structural Integrity) (20.10.2025) No 5 02140 STRUCTURAL CONDITIONS (Towing And Mooring Equipment) (20.10.2025) No |
| 20 Oct 2025 | Jiangyin | No | 61 07115 FIRE SAFETY (Fire-Dampers) No 2 03103 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) No 3 07109 FIRE SAFETY (Fixed Fire Extinguishing Installation) No 4 07101 FIRE SAFETY (Fire Prevention Structural Integrity) No 5 02140 STRUCTURAL CONDITIONS (Towing And Mooring Equipment) No 6 02140 STRUCTURAL CONDITIONS (Towing And Mooring Equipment) No |
| 28 Feb 2025 | Odesa | No | 0 |
| 09 Jan 2025 | Bjorneborg (Pori) | No | 0 |
| 25 Mar 2024 | Kocaeli | No | 4Structural Conditions 02112 - Hull - Corrosion Corroded Safety Of Navigation 10199 - Other (Navigation) Other Safety Of Navigation 10103 - Radar Not Approved Fire Safety 07105 - Fire Doors/Openings In Fire-Res |
| 24 Jul 2023 | Lisbon | No | 10Structural Conditions; 02103 - Stability/Strength/Loading Information And Instruments; Not As Required; Structural Conditions; 02103 - Stability/Strength/Loading Information And Instruments; Not As Required; Certificate & Documentation - Documents; 01311 - Survey Report File; Documentation Missing; Structural Conditions; 02117 - Decks - Corrosion; Corroded; Safety Of Navigation; 10101 - Pilot Ladders And Hoist/Pilot Transfer Arrangements; Unsafe; Safety Of Navigation; 10104 - Gyro Compass; Inoperative; Emergency Systems; 04109 - Fire Drills; Lack Of Training; Pollution Prevention - Ballast Water; 14802 - Ballast Water Record Book; Not Properly Filled; Pollution Prevention - Ballast Water; 14801 - Ballast Water Management Plan; Not Updated; ISM; 15150 - ISM; Not As Required |
| 31 Aug 2022 | Nantes | No | 401139, Maritime Labour Certificate, Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled, 02128, Bulk Carriers Add.Safety Measures, Structural Conditions, 1190, Leaking, 18306, Sleeping Room, Additional Spaces, Labour Conditions - Ac |
| 28 Apr 2022 | Casablanca | No | 0 |
| 24 Mar 2022 | Gent (Ghent) | No | 1018419, Adequate Lighting - Mooring Arrangements, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 99101, Other Safety In General, Other, 1238, Other, 01139, Maritime Labour Certificate, Certificate & Documentation - Ship Certificates, 1250, See Comment, 10101, Pilot Ladders And Hoist/Pilot Transfer Arrangements, Safety Of Navigation, 1027, Unsafe, 02128, Bulk Carriers Add.Safety Measures, Structural Conditions, 1011, Not As Required, 07111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required, 14105, Pumping, Piping And Discharge Arrangements, Pollution Prevention - Marpol Annex I, 1011, Not As Required, 15150, ISM, ISM, 1011, Not As Required, 01101, Cargo Ship Safety Equipment (Including Exemption), Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled, 13104, Bilge Pumping Arrangements, Propulsion And Auxiliary Machinery, 1082, Inoperative, |
| 11 Oct 2021 | Aliaga | No | 7Application For Endorsement By Flagstate; Document Of Compliance (DoC/ ISM); Emergency Source Of Power - Emergency Generator; Fire Fighting Equipment And Appliances; Gauges, Thermometers, Etc; Inflatable Liferafts; Lifeboats |
| 11 Oct 2021 | Aliaga | No | 0 |
| $15.15M |
| Unknown |