Vessel
CALIPSO
IMO 9297929
CargoBuilt 2005Active
40,230
Gross tonnageA measure of the vessel's total internal volume (not its weight).
73,691
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
—
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2005
Year built
Live position & voyage
LIVELoading position…
Particulars
- IMO
- 9297929
- MMSI
- 311912000
- Call sign
- C6UH2
- Flag
- BS
- Type
- Bulk Carrier
- Length (LOA)
- 225 m
- Beam
- 32.3 m
- Home port
- NASSAU
Ownership
- Beneficial owner
- —
- Operator
- Diana Wilhelmsen· Cyprus
- Technical manager
- Diana Wilhelmsen
- Commercial manager
- Diana Wilhelmsen
- Class society
- LR
- Design DWT
- 73,691 t
- Flag
- Bahamas
- Built
- 2005
Timeline
key events over the vessel's life- Special survey
- Dry dock
- Casualty · Mechanical FaultVessel under the conduct of a pilot reported was disabled due to problems with e
- Sold$7.3M
- Built
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- 19 Apr 2028
- Special survey
- 02 Feb 2030
- IOPP issued
- 14 Apr 2025
- IOPP expires
- 02 Feb 2030
Shipments carried
recent bills of ladingNo shipment records.
Inspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 04 Jun 2026 | Satui | No | 0 |
| 02 Apr 2026 | Bontang | No | 0 |
| 20 Jan 2026 | Banjarmasin | No | 31 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (07.01.2025) No 2 01123 CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Continuous Synopsis Record) (28.10.2025) No 3 02120 STRUCTURAL CONDITIONS (Marking Of IMO Number) (28.10.2025) No |
| 20 Jan 2026 | Banjarmasin | No | 1FIRE SAFETY (International Shore-Connection) |
| 28 Oct 2025 | Pyeongtaek | No | 31 01123 CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Continuous Synopsis Record) No 2 11104 LIFE SAVING APPLIANCES (Rescue Boats) No 3 02120 STRUCTURAL CONDITIONS (Marking Of IMO Number) No |
| 13 Mar 2025 | Vung Tau | No | 1LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Lighting (Accommodation)) |
| 09 Feb 2025 | Seattle | No | 3System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Component: 09209 - Electrical Cause: Improper/Lack Of Maintenance Action: 10 - Deficiency Rectified Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: EXPOSED METAL PARTS OF ELECTRICAL MACHINES OR EQUIPMENT WHICH ARE NOT INTENDED TO BE LIVE BUT WHICH ARE LIABLE UNDER FAULT CONDITIONS TO BECOME LIVE SHALL BE EARTHED UNLESS THE MACHINES OR EQUIPMENT ARE SUPPLIED AT A VOLTAGE NOT EXCEEDING 250V BY SAFETY ISOLATING TRANSFORMERS SUPPLYING ONLY ONE CONSUMING DEVICE. MULTIPLE MOTORS IN THE PURIFIER SPACE AND ENGINE ROOM WITH EARTHING WIRES WERE DISCONNECTED. 74 SOLAS 04 II-1/45.1.1.2 Due Date: 2/9/2025 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 2/9/2025 12:00:00 AM Resolution Description: GROUNDING WIRES WERE REINSTALLED. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07111 - Personal Equipment For Fire Safety Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: PERSONAL EQUIPMENT SHALL CONSIST OF THE FOLLOWING... PROTECTIVE CLOTHING OF MATERIAL TO PROTECT THE SKIN FROM THE HEAT RADIATING FROM THE FIRE AND FROM BURNS AND SCALDING BY STEAM. THE OUTER SURFACE SHALL BE WATER-RESISTANT. PSCO OBSERVED TEARS IN FIRE FIGHTING HOODS, NOT PROTECTING THE SKIN FROM HEAT. 74 SOLAS 09 II-2/10.10.1 FSS CODE CH.3.2.1.1.1 Due Date: 2/14/2025 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 5/15/2025 12:00:00 AM Resolution Description: Vessel Sent Receipts And Approval Certificates For New Firefighting Suits. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07109 - Fixed Fire Extinguishing Installation Cause: Improper/Lack Of Maintenance Action: 10 - Deficiency Rectified Action Code: D - To The Satisfaction Of SIP/TBSIP Coordinator Description Of Deficiency: THE PURPOSE OF THIS REGULATION IS TO MAINTAIN AND MONITOR THE EFFECTIVENESS OF THE FIRE SAFETY MEASURES THE SHIP IS PROVIDED WITH. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE... 02 CARBON DIOXIDE CYLINDERS HAD PINS INSTALLED PREVENTING IMEEDIATE USE. 74 SOLAS 09 II-2/14.1.1 Due Date: 2/9/2025 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 2/9/2025 12:00:00 AM Resolution Description: PINS WERE REMOVED. |
| 07 Jan 2025 | Taizhou, Jiangsu | No | 11 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) No |
| 01 Aug 2024 | Rizhao | No | 81 03112 WATER/WEATHERTIGHT CONDITIONS (Scuppers, Inlets And Discharges) (29.07.2024) Yes 2 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) (29.07.2024) Yes 3 07113 FIRE SAFETY (Fire Pumps And Its Pipes) (29.07.2024) Yes 4 07109 FIRE SAFETY (Fixed Fire Extinguishing Installation) (29.07.2024) Yes 5 07101 FIRE SAFETY (Fire Prevention Structural Integrity) (29.07.2024) Yes 6 10109 SAFETY OF NAVIGATION (Lights, Shapes, Sound-Signals) (29.07.2024) No 7 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) (29.07.2024) No 8 04113 EMERGENCY SYSTEMS (Water Level Indicator) (29.07.2024) No |
| 29 Jul 2024 | Rizhao | Yes | 91 03112 WATER/WEATHERTIGHT CONDITIONS (Scuppers, Inlets And Discharges) Yes 2 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) Yes 3 07113 FIRE SAFETY (Fire Pumps And Its Pipes) Yes 4 07109 FIRE SAFETY (Fixed Fire Extinguishing Installation) Yes 5 07101 FIRE SAFETY (Fire Prevention Structural Integrity) Yes 6 10109 SAFETY OF NAVIGATION (Lights, Shapes, Sound-Signals) No 7 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) No 8 04113 EMERGENCY SYSTEMS (Water Level Indicator) No 9 15109 ISM (Maintenance Of The Ship And Equipment) No |
| 23 Feb 2024 | Jiangyin | No | 3SAFETY OF NAVIGATION (Lights, Shapes, Sound-Signals) No 2 04102 EMERGENCY SYSTEMS (Emergency Fire Pump And Its Pipes) No 3 11101 LIFE SAVING APPLIANCES (Lifeboats) |
| 07 Jun 2023 | Humen | No | 4LIFE SAVING APPLIANCES (Launching Arrangements For Survival Craft); LIFE SAVING APPLIANCES (Stowage And Provision Of Liferafts); POLLUTION PREVENTION - BALLAST WATER (Ballast Water Exchange); FIRE SAFETY (Fire Detection And Alarm System) |
| 29 Sep 2021 | Rouen | No | 1Lighting (Working Spaces); Inoperative |
Casualties
| Date | Type | Details |
|---|---|---|
| 15 Feb 2021 | Mechanical Fault | Vessel under the conduct of a pilot reported was disabled due to problems with engine while berthed at Ridley Terminals, Prince Rupert, BC, Canada, in position 54 13 22.2N 130 20 09.6W on 15 Feb 2021. Crew carried out repairs. |
Sale & demolition history
reported transactions & recycling| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 03 Jan 2020 | Reported SoldSS due 2/20. | $7.3M | — |