Loading…

| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 02 May 2026 | Baltimore | No | 0 |
| 20 Aug 2025 | Sydney | No | 0 |
| 30 May 2023 | Gibraltar | No |
| Date | Type | Details |
|---|---|---|
| 18 Jul 2023 | Mechanical Fault | Vessel had propeller fault one hour after leaving Ostsee Quay, Kiel, Germany. She sailed in legs in Kiel Bight and anchored off Langeland Isl. Crew couldn't fix damage and was towed to E Shore Port on 21 July. |
| 08 May 2016 | Collision | In contact with passenger boarding bridge as it was arriving in Baltimore 08 May 2016. Minor damage. Sd same day. |
| 0 |
| 09 Apr 2023 | St Petersburg, Florida | No | 7System: 04 - Emergency Systems Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: 04109 - Fire Drills - Crew Members Shall Be Trained To Be Familiar With The Arrangements Of The Ship As Well As The Location And Operation Of Any Fire-Fighting Systems And Appliances That They May Be Called Upon To Use. PSCO Observed Main Galley, Pizzeria, And Good Eats Crew Members Were Unfamiliar With Ship'S Manual Call Points, Fire Extinguishing Equipment, And Hi-Fog Fire Suppression System For Deep Fat Fryer. 74 SOLAS (20) II-2/15.2.2.1 17c Due Date: 4/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/9/2023 12:00:00 AM Resolution Description: Crew Was Trained And Re-Questioned By CG. System: 04 - Emergency Systems Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: 04109 - Fire Drills - Every Crew Member With Assigned Emergency Duties Shall Be Familiar With These Duties Before The Voyage Begins. PSCO Observed Insufficient Evacuation Of Crew Accommodations Surrounding The Affected Space During The Fire Drill. 74 SOLAS (20) III/19.2.1 17c Due Date: 4/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/9/2023 12:00:00 AM Resolution Description: Crew Repeated Fire Drill And Improved Evacuation Procedures. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: 07105 - Fire Doors/Openings In Fire-Resisting Divisions - Fire Doors In Main Vertical Zone Bulkheads And Stairway Enclosures Shall Satisfy The Following Requirements: The Doors Shall Be Self-Closing. PSCO Observed FSD B302 Did Not Self-Close Completely. 74 SOLAS (01) II-2/30.4.1 10c Due Date: 4/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/9/2023 12:00:00 AM Resolution Description: Door Adjusted And Closed Satisfactorily While CG Onboard. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: 07105 - Fire Doors/Openings In Fire-Resisting Divisions - Fire Doors In Main Vertical Zone Bulkheads, Galley Boundaries, And Stairway Enclosures, Other Than Power-Operated Watertight Doors And Those Which Are Normally Locked, Shall Satisfy The Following Requirements: The Door Shall Be Self-Closing And Capable Of Closing Against An Angle Of Inclination Of Up To 3.5 Degrees Opposing Closure. PSCO Observed FSD In Raphael Room, Deck 3, Had Paintings Obstructing The Closing Of The Door. 74 SOLAS (01) II-2/30 17c Due Date: 4/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/9/2023 12:00:00 AM Resolution Description: Crew Removed Paintings From This Location While CG Was Onboard. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: 07105 - Fire Doors/Openings In Fire-Resisting Divisions - The Construction Of All Doors And Door Frames In A Class Divisions, With The Means Of Securing Them When Closed, Shall Provide Resistance To Fire As Well As The Passage Of Smoke And Flame, As Far As Practicable, Equivalent To That Of The Bulkheads In Which The Doors Are Situated. Such Doors And Door Frames Shall Be Constructed Of Steel Or Other Equivalent Material. PSCO Observed FSD 4.14 Did Not Latch When Closed. 74 SOLAS (01) II-2/30.2 10c Due Date: 4/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/9/2023 12:00:00 AM Resolution Description: Door Adjusted And Tested Sat While CG Onboard. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: 07120 - Means Of Escape - The Means Of Escape, Including Stairways And Exits, Shall Be Marked By Lighting Or Photoluminescent Strip Indicators Placed Not More Than 300 Mm Above The Deck At All Points Of The Escape Route, Including Angles And Intersections. The Marking Must Enable Passengers To Identify The Routes Of Escape And Readily Identify The Escape Exits. PSCO Observed Low Location Lighting, In The Vicinity Of WTD #18, Did Not Illuminate. 74 SOLAS (01) II-2/28.1.5.10 10c Due Date: 4/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/9/2023 12:00:00 AM Resolution Description: Repaired By Crew While CG Onboard. System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: 11101 - Lifeboats - Before The Ship Leaves Port And At All Times During The Voyage, All Life-Saving Appliances Shall Be In Working Order And Ready For Immediate Use. PSCO Observed Lifeboat #12 Did Not Start. 74 SOLAS (20) III/20.2 17c Due Date: 4/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/9/2023 12:00:00 AM Resolution Description: Crew Repaired Lifeboat Engine And Was Able To Demonstrate A Satisfactory Start To CG. |
| 01 Feb 2023 | Belize City | No | 0 |
| 13 May 2022 | Vigo | No | 0 |