BoatDB
Vessel

CASTLEGATE

IMO 9460318
CargoBuilt 2008Active
CASTLEGATE — vessel photo
Photo: Calistemon · CC BY-SA 4.0 · via Wikimedia Commons
29,923
Gross tonnageA measure of the vessel's total internal volume (not its weight).
53,503
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2008
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9460318
MMSI
636015902
Call sign
D5DK3
Flag
LR
Type
Bulk Carrier
Length (LOA)
189.9 m
Beam
32.26 m
Home port
MONROVIA

Ownership

Beneficial owner
Operator
Technical manager
Zodiac Maritime
Commercial manager
Zodiac Maritime
Class society
LR
Design DWT
53,503 t
Flag
Liberia
Built
2008

Timeline

key events over the vessel's life
  1. Dry dock
  2. Special survey
  3. Sold
    $12.9M
  4. Sold
    $11M
  5. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
24 Apr 2027
Special survey
24 Apr 2027
IOPP issued
31 Jan 2023
IOPP expires
24 Apr 2027

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
30 Jan 2026SalaverryNo0
03 Apr 2025TokuyamaNo0
29 Oct 2024Port Moody/VancouverNo107120, Means Of Escape, Fire Safety, 1011, Not As Required,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
07 Aug 2024GuangzhouNo31 11103 LIFE SAVING APPLIANCES (Stowage And Provision Of Lifeboats) (07.08.2024) No 2 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) (07.08.2024) No 3 05118 RADIO COMMUNICATIONS (Operation Of GMDSS Equipment) (07.08.2024) No
07 Aug 2024GuangzhouNo41 11103 LIFE SAVING APPLIANCES (Stowage And Provision Of Lifeboats) No 2 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) No 3 03105 WATER/WEATHERTIGHT CONDITIONS (Covers (Hatchway-, Portable-, Tarpaulins, Etc.)) No 4 05118 RADIO C
12 Jan 2024QuangninhNo0
08 Nov 2023Misumi, KumamotoNo0
18 Aug 2023CilacapNo0
22 Apr 2023Houston, TexasNo0
14 Jun 2022VancouverNo0
04 Feb 2022MollendoNo181 07109 FIRE SAFETY (Fixed Fire Extinguishing Installation) (15.07.2021) No 2 18418 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Winches & Capstans) (15.07.2021) No 3 03103 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) (15.07.2021) No 4 03103 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) (15.07.2021) No 5 11117 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) (15.07.2021) No 6 14501 POLLUTION PREVENTION - MARPOL ANNEX V (Garbage) (15.07.2021) No 7 04105 EMERGENCY SYSTEMS (Location Of Emergency Installations) (15.07.2021) No 8 07105 FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) (15.07.2021) No 9 07106 FIRE SAFETY (Fire Detection And Alarm System) (15.07.2021) No 10 07123 FIRE SAFETY (Operation Of Fire Protection Systems) (15.07.2021) No 11 07117 FIRE SAFETY (Jacketed High Pressure Lines And Oil Leakage Alarm) (15.07.2021) No 12 11115 LIFE SAVING APPLIANCES (Means Of Rescue) (15.07.2021) No 13 11115 LIFE SAVING APPLIANCES (Means Of Rescue) (15.07.2021) No 14 18423 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Preventative Information) (15.07.2021) No 15 14501 POLLUTION PREVENTION - MARPOL ANNEX V (Garbage) (15.07.2021) No 16 14599 POLLUTION PREVENTION - MARPOL ANNEX V (Other MARPOL Annex V) (15.07.2021) No 17 18314 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Provisions Quantity) (15.07.2021) No 18 07101 FIRE SAFETY (Fire Prevention Structural Integrity) (15.07.2021) No
15 Jul 2021VancouverNo1818423, Preventative Information, Labour Conditions - Health Protection, Medical Care, Social Security, 1000, Missing, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1027, Unsafe, 11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 1011, Not As Required, 14599, Other MARPOL Annex V, Pollution Prevention - Marpol Annex V, 1238, Other, 18418, Winches & Capstans, Labour Conditions - Health Protection, Medical Care, Social Security, 1086, Not Properly Maintained, 03103, Railing, Gangway, Walkway And Means For Safe Passage, Water/Weathertight Conditions, 1011, Not As Required, 03103, Railing, Gangway, Walkway And Means For Safe Passage, Water/Weathertight Conditions, 1029, Corroded, 14501, Garbage Shipboard Handling, Pollution Prevention - Marpol Annex V, 1011, Not As Required, 14501, Garbage Shipboard Handling, Pollution Prevention - Marpol Annex V, 1011, Not As Required, 11115, Means Of Rescue, Life Saving Appliances, 1011, Not As Required, 11115, Means Of Rescue, Life Saving Appliances, 1011, Not As Required, 18314, Provisions Quantity, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1036, Insufficient, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 07101, Fire Prevention Structural Integrity, Fire Safety, 1011, Not As Required, 07106, Fire Detection And Alarm System, Fire Safety, 1086, Not Properly Maintained, 04105, Location Of Emergency Installations, Emergency Systems, 1011, Not As Required, 07117, Jacketed High Pressure Lines And Oil Leakage Alarm, Fire Safety, 1011, Not As Required, 07123, Operation Of Fire Protection Systems, Fire Safety, 1011, Not As Required

Sale & demolition history

reported transactions & recycling
DateEventPriceReported sale price in US$ millions.Buyer
22 Jun 2026 Reported Sold$12.9MUnknown
28 Jun 2025 Reported SoldDD 07/2025$11MUnknown