BoatDB
Vessel

CELESTE ACE

IMO 9982990
CargoBuilt 2024Active
Gross tonnageA measure of the vessel's total internal volume (not its weight).
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2024
Year built

Live position & voyage

LIVE
Loading position…

Shipments over time

bills of lading per month

Particulars

IMO
9982990
MMSI
352004036
Call sign
3E5420
Flag
PA
Type
Vehicles Carrier
Length (LOA)
199.96 m
Beam
38 m
Home port

Ownership

Beneficial owner
Operator
Technical manager
Commercial manager
Class society
NK
Design DWT
18,650 t
Flag
Built

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
12 Sep 2027
Special survey
12 Sep 2029
IOPP issued
13 Sep 2024
IOPP expires
12 Sep 2029

Top importers served

importers this vessel carried for

Shipments carried

recent bills of lading
ArrivalImporterProductB/L
08 Jan 2026Isuzu North America Corpship no. isuzu chassis with cab (un ,engines,internal combustio n,class ) ---- ------------------------------- for truck mo del npr --or nrr single cab --or crew-cab ty pe with piston engine tool kit, for yea r model (diesel) waybill freight prepaid as arMOLU18008291443
08 Jan 2026Alexander Reymarused vehicle honda s-mx chassis no.rh - manufacture year : ref.no.ca hs code: . x x - company code :MOLU18008294252
08 Jan 2026Alexander Reymarused vehicle unit ref no : cb make model name : honda acty van ch-no. : hh - lwh : . x . x . m . m w eight : . kg manufacture year : hs code: . -freight prepaid as arranged- - company code : = haze lnut @yahoo.comMOLU18008294273
08 Jan 2026Stephen Leonused vehicle unit ref no : bx ma ke model name: suzuki every ch-no. : de v- lwh : . x . x . m . m weight : . kg manufacture year : h s code: . - company code : = madabird @gmail.comMOLU18008330771
08 Jan 2026Unknownused vehicle unit ref no : bx ma ke model name : honda z ch-no. : pa - lwh : . x . x . m . m weight : . kg manufacture year : hs code : . - company code : = hartjamesm@gmail.comMOLU18008330750
08 Jan 2026Unknownused vehicle unit ref no : ca ma ke model name : honda life ch-no. : jb - lwh : . x . x . m . m wei ght : . kg manufacture year : hs c ode: . - company code : = hartjamesm@gmail.comMOLU18008330766
07 Jan 2026Adam Nivused vehicle chevrolet astro starcraft chas sis no.ai ai year: serial no. gbdm w xb hs code: . x x # termarrac@awis.usMOLU18008330690
07 Jan 2026Adrian Michael Croninused motor vehicle(s) ncp - toyota will vi year: x x hs code: .MOLU18008329662
07 Jan 2026Alexander Gaborasused vehicle nissan silvia chassis no. : s - x x hs code: . # e-mail: sebastian@omegachb.comMOLU18008294144
07 Jan 2026Americ Machinery Corpused caterpillar bull dozer model: d k lgp serial: cat d kakl year: hs cod e: .NMCCCE008LOSY004
07 Jan 2026Arizona Kei Trucks Llcas per attached sheet # contact: sebastia n vasquezMOLU18008329699
07 Jan 2026Az Vehicle Importers Llcused vehicle toyota bb chassis no.ncp - year: hs cde: . x x - fax : + - - -MOLU18008327211
07 Jan 2026Carl Joven Macasinag 31725 Brentworth St Menifee Ca 92584 Usaused vehicle nissan skyline ch-no. hr - year : hs code : . lwh : x xMOLU18008328223
07 Jan 2026Carlos Enrique Mendez Santizoused vehicle(s) description as per attached sheet # email:erin@davidsonandsons.comMOLU18008328814
07 Jan 2026Christian Mcdanielused vehicle unit ref no : ca ma ke model name : honda street ch-no. : hh - lwh : . x . x . m . m w eight : . kg manufacture year : hs code: . - company code : = cmmcdaniel@hotmail.comMOLU18008328856

Inspections

recent port state control
DatePortDetainedDeficiencies
07 Jan 2026San PedroNo6System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Invalid Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: A Caution Placard To Signboard Shall Be Permanently Fitted In The Machinery Space Containing Gas-Fueled Engines Stating That Heavy Lifting, Implying Danger Of Damage To The Fuel Pipes, Shall Not Be Done When The Engine(S) Is Running. Ship Does Not Have Sign Posted. 74 SOLAS (20) II-1/57; IGF Code (2016) 15.11.3 Due Date: 1/21/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/20/2026 12:00:00 AM Resolution Description: PSCO Received Class Survey Report And Photographs Confirming Heavy Lifting Caution Placards Have Been Permanently Posted In The ECR, E/R, And GPR Entrance. System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Invalid Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: A Fuel System Schematic/Piping And Instrumentation Diagram (P&ID) Shall Be Reproduced And Permanently Mounted In The Ship'S Bunkering Control Station And At The Bunker Station. P&ID Is Not Posted At The Bunkering Control Station. 74 SOLAS (20) II-1/57; IGF Code (2016) 18.4.2.2 Due Date: 1/21/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/20/2026 12:00:00 AM Resolution Description: PSCO Received Class Survey Report Confirming The P&ID Is Permanently Mounted At The Bunkering Control Station (ECR). System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Invalid Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: If A Fuel Leak Leading To A Fuel Supply Shutdown Occurs, The Fuel Supply Shall Not Be Operated Until The Leak Has Been Found And Dealt With. Instructions To This Effect Shall Be Placed In A Prominent Position In The Machinery Space. Ship Does Not Have Sign Posted. 74 SOLAS (20) II-1/57; IGF Code (2016) 15.11.2 Due Date: 1/21/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/20/2026 12:00:00 AM Resolution Description: PSCO Received Class Survey Report And Photographs Confirming The Notices Regarding Fuel Supply Shutoff By A Fuel Leak Have Been Permanently Posted In The ECR, E/R, And GPR Entrance. System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Invalid Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: If The Fuel Supply Is Shutoff Due To Activation Of An Automatic Valve, The Fuel Supply Shall Not Be Opened Until The Reason For Diconnection Is Ascertained. A Readily Visible Notice Giving Instruction To This Effect Shall Be Placed At The Operating Station For The Shutoff Valves In The Fuel Machinery Space. Ship Does Not Have Sign Posted. 74 SOLAS (20) II-1/57; IGF Code (2016) 15.11.1 Due Date: 1/21/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/20/2026 12:00:00 AM Resolution Description: PSCO Received Class Survey Report And Photographs Confirming The Notices Regarding Fuel Supply Shutoff By An Automatic Valve Have Been Permanently Posted In The ECR, E/R, And GPR Entrance. System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Invalid Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Bunkering Station Shall Be Located On Open Deck So That Sufficient Natural Ventilation Is Provided. Closed Or Semi-Closed Bunkering Stations Shall Be Subject To Special Consideration Within The Risk Assessment. Vessel Has A Semi-Enclosed Bunker Station That Is Not Addressed In The Risk Assessment. 74 SOLAS (20) II-1/57; IGF Code (2016) 8.3.1.1 Due Date: 2/6/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/20/2026 12:00:00 AM Resolution Description: PSCO Received Class Risk Assessment For LNG Fueled Pure Car Carrier Addressing The Hazards Associated With A Semi-Enclosed Bunker Station. System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13101 - Propulsion Main Engine Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Closing Time Of The Bunkering Station Liquid Fill Valve Shall Close At No Greater Than 5 Seconds. Valve Closed In 10 Seconds. 74 SOLAS (20) II-1/57; IGF Code (2016) 16.7.3.7 Due Date: 1/21/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/25/2026 12:00:00 AM Resolution Description: PSCO Received Class Report Accepting The Extended Closing Time Of The Bunker Valve Based On Pressure Surge Considerations IAW IGF Code 8.5.8.
09 Oct 2025KoperNo0
08 Jul 2025YokohamaNo0
20 Jun 2025SeattleNo0
14 Nov 2024South ShieldsNo0
18 Sep 2024HiroshimaNo0