| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 10 Apr 2026 | FPO, Armed Forces Pacific | No | 0 |
| 25 Jul 2023 | Fpo, Ap, Guam | No | 7System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: Fire Detection And Fire Alarm System Shall Be Kept In Good Order So As To Ensure Their Required Performance If A Fire Occurs. There Is An Active Fault In The Fire Detection Panel For Zone 7. 74 SOLAS (09) II-2/Reg 14.2.1.1.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 8/3/2023 4:37:12 AM Resolution Description: N/A System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: Launching And Recovery Arrangements Shall Be Such That The Appliance Operator On The Ship Is Able To Observe The Survival Craft At All Times During Launching And For Lifeboats During Recovery. During Launching Of The #3 Lifeboat, The Davit'S Lowering Handle Disconnected From The Cable. 74 SOLAS (14) III/Reg 16.3 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 8/3/2023 4:41:01 AM Resolution Description: N/A System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained And No Change Shall Be Made In The Structural Arrangements, Machinery, Equipment, And Any Other Items Covered By The Survey, Without The Sanction Of The Administration. The #2 Main Diesel Generator Is Unable To Start. 74 SOLAS (09) I/Reg 11 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 8/3/2023 4:40:20 AM Resolution Description: N/A System: 04 - Emergency Systems Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained And No Change Shall Be Made In The Structural Arrangements, Machinery, Equipment, And Any Other Items Covered By The Survey, Without The Sanction Of The Administration. The Emergency Generator Switchboard Hertz Meter Is Inoperable And The 12V Ground Detection Indicating Lights Are Blinking. 74 SOLAS (09) I/Reg 11 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 8/3/2023 4:41:59 AM Resolution Description: N/A System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained And No Change Shall Be Made In The Structural Arrangements, Machinery, Equipment, And Any Other Items Covered By The Survey, Without The Sanction Of The Administration. The Engine Room'S Supply And Exhaust Fans M2, M6, M8, And M10 Are Inoperable. 74 SOLAS (09) I/Reg 11 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 8/3/2023 4:45:44 AM Resolution Description: N/A System: 99 - Other Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained And No Change Shall Be Made In The Structural Arrangements, Machinery, Equipment, And Any Other Items Covered By The Survey, Without The Sanction Of The Administration. The Eye Wash Station Located In The Incinerator Room Is Inoperable. 74 SOLAS (09) I/Reg 11 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 8/3/2023 4:44:10 AM Resolution Description: N/A System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained And No Change Shall Be Made In The Structural Arrangements, Machinery, Equipment, And Any Other Items Covered By The Survey, Without The Sanction Of The Administration. The Port And Stbd Rescue Boats Have Damages To The Self-Righting Buoyant Canopy Caused By The Launching Handle. In Addition, The Stbd Rescue Boat'S Seat Back Rest For The Operator Has Broken Off. 74 SOLAS (09) I/Reg 11 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 8/3/2023 4:42:47 AM Resolution Description: N/A |