Loading…
| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 22 Jul 2025 | E C O Fertilizers Inc | urea ammonium nitrate solutions (aun) | bgnrcgua03250100 |
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 08 Apr 2026 | Jianyang | No | 31 03103 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) (04.04.2026) No 2 11134 LIFE SAVING APPLIANCES (Operation Of Life Saving Appliances) (04.04.2026) No 3 07114 FIRE SAFETY (Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces) (04.04.2026) No |
| 04 Apr 2026 | Jiangyin |
| No |
| 3WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) No 2 11134 LIFE SAVING APPLIANCES (Operation Of Life Saving Appliances) No 3 07114 FIRE SAFETY (Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces) No |
| 08 Jan 2026 | Porto Foxi (Sarroch) | No | 1615150, ISM, ISM, 1011, Not As Required,07199, Other (Fire Safety), Fire Safety, 1238, Other,12108, Personal Protection, Dangerous Goods, 1011, Not As Required,18428, On Board Programme For The Prevention Of Occupational Injuries And Deaseases, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,07116, Ventilation, Fire Safety, 1011, Not As Required,11101, Lifeboats, Life Saving Appliances, 1026, Damaged,14205, Cargo Heating Systems - Cat Y Substances, Pollution Prevention - Marpol Annex II, 1026, Damaged,02105, Steering Gear, Structural Conditions, 1011, Not As Required,03112, Scuppers, Inlets And Discharges, Water/Weathertight Conditions, 1086, Not Properly Maintained,01318, P&A Manual, Certificate & Documentation - Documents, 1009, Not Approved,01101, Cargo Ship Safety Equipment (Including Exemption), Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled,01334, STS Operation Plan And Records Of STS Operations, Certificate & Documentation - Documents, 1011, Not As Required,01306, Shipboard Working Arrangements, Certificate & Documentation - Documents, 1011, Not As Required,01308, Records Of Seafarers' Daily Hours Of Work Or Rest, Certificate & Documentation - Documents, 1255, Incorrect Entries,01329, Report Of Inspection On MLC,2006, Certificate & Documentation - Documents, 1011, Not As Required,02127, Safe Access To Tanker Bows, Structural Conditions, 1011, Not As Required |
| 06 Nov 2025 | Lianyungang | No | 41 10110 SAFETY OF NAVIGATION (Signalling Lamp) No 2 07110 FIRE SAFETY (Fire Fighting Equipment And Appliances) No 3 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) No 4 18315 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Provisions Quality And Nutritional Value) No |
| 22 Jul 2025 | New Orleans | No | 0 |
| 07 Apr 2025 | Nanjing | No | 9ISM (Maintenance Of The Ship And Equipment) No 2 07199 FIRE SAFETY (Other (Fire Safety)) No 3 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) No 4 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) No 5 07113 FIRE SAFETY (Fire Pumps And Its Pipes) No 6 06199 CARGO OPERATIONS INCLUDING EQUIPMENT (Other (Cargo)) No 7 08199 ALARMS (Other (Alarms)) No 8 07108 FIRE SAFETY (Ready Availability Of Fire Fighting Equipment) No 9 02116 STRUCTURAL CONDITIONS (Bulkheads - Cracking) |
| 19 Oct 2024 | Novorossiisk | No | 101 EMERGENCY SYSTEMS (Public Address System) Rectify Deficiency Before Departure Deficiency Rectified 2 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship)) Rectify Deficiency Within 14 Days 3 SAFETY OF NAVIGATION (Voyage Data Recorder (VDR)/Simplified Voyage Data Recorder(S-VDR)) Rectify Deficiency Within 14 Days 4 FIRE SAFETY (Ready Availability Of Fire Fighting Equipment) Rectify Deficiency Within 14 Days Deficiency Rectified 5 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Before Departure Deficiency Rectified 6 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Before Departure Deficiency Rectified 7 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) Rectify Deficiency Before Departure Deficiency Rectified 8 CARGO OPERATIONS INCLUDING EQUIPMENT (Cargo Transfer - Tankers) Rectify Deficiency Before Departure Deficiency Rectified 9 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Within 14 Days 10 LIFE SAVING APPLIANCES (On Board Training And Instructions) Rectify Deficiency Before Departure Deficiency Rectified |
| 29 May 2024 | Ceyhan | No | 6Living And Working Conditions - Working Conditions - Gangway, Accommodation-Ladder Not Properly Maintained ; Radio Communications - Operation/Maintenance Not As Required ; Safety Of Navigation - Pilot Ladders And Hoist/Pilot Transfer Arrangements Damaged ; Structural Conditions - Decks - Corrosion Holed ; Structural Conditions - Ballast, Fuel And Other Tanks Not As Required ; Pollution Prevention - Marpol Annex V - Garbage Shipboard Handling Not As Required |
| 11 May 2023 | Zeebrugge | No | 13SOx Records Not As Required ; Record Of Drills And Steering Gear Tests Missing ; Fire Pumps And Its Pipes Not As Required ; Fire-Dampers Inoperative ; Propulsion Main Engine Not As Required ; Bilge Pumping Arrangements Not As Required ; Electrical Installations In General Not Properly Maintained ; Decks - Corrosion Corroded ; Insulation Wetted Through (Oil) Damaged ; Galley, Handlingroom (Maintenance) Not As Required ; Other (Machinery) Other ; ISM Not As Required ; Fire Drills Lack Of Knowledge |
| 10 Jan 2023 | Teluk Bayur | No | 0 |
| 25 Jul 2022 | Rotterdam | No | 1310127, Voyage Or Passage Plan, Safety Of Navigation, 1011, Not As Required, 01324, Material Safety Data Sheets(MSDS), Certificate & Documentation - Documents, 1000, Missing, 10111, Charts, Safety Of Navigation, 1179, Not Updated, 07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required, 07106, Fire Detection And Alarm System, Fire Safety, 1082, Inoperative, 15150, ISM, ISM, 1011, Not As Required, 07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1082, Inoperative, 11101, Lifeboats, Life Saving Appliances, 1047, Not Ready For Use, 07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1000, Missing, 07123, Operation Of Fire Protection Systems, Fire Safety, 1208, Lack Of Familiarity, 18314, Provisions Quantity, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1036, Insufficient, 13106, Insulation Wetted Through (Oil), Propulsion And Auxiliary Machinery, 1036, Insufficient, 03109, Machinery Space Openings, Water/Weathertight Conditions, 1011, Not As Required, |
| 24 Aug 2021 | Antwerpen | No | 2218425, Access / Structural Features (Ship), Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 01220, Seafarers' Employment Agreement (SEA), Certificate & Documentation - Crew Certificates, 1001, Invalid, 15150, ISM, ISM, 1011, Not As Required, 02109, Permanent Means Of Access, Structural Conditions, 1027, Unsafe, 18422, Asbestos Fibres, Labour Conditions - Health Protection, Medical Care, Social Security, 1086, Not Properly Maintained, 14615, Fuel Change-Over Procedure, Pollution Prevention - Marpol Annex VI, 1000, Missing, 07125, Evaluation Of Crew Performance (Fire Drills), Fire Safety, 1208, Lack Of Familiarity, 04101, Public Address System, Emergency Systems, 1000, Missing, 10101, Pilot Ladders And Hoist/Pilot Transfer Arrangements, Safety Of Navigation, 1027, Unsafe, 99101, Other Safety In General, Other, 1238, Other, 11112, Launching Arrangements For Survival Craft, Life Saving Appliances, 1086, Not Properly Maintained, 04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1011, Not As Required, 18312, Galley, Handlingroom (Maintenance), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 07111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required, 18428, On Board Programme For The Prevention Of Occupational Injuries And Deaseases, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 07116, Ventilation, Fire Safety, 1011, Not As Required, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 04117, Functionality Of Safety Systems, Emergency Systems, 1011, Not As Required, 07113, Fire Pumps And Its Pipes, Fire Safety, 1011, Not As Required, 03112, Scuppers, Inlets And Discharges, Water/Weathertight Conditions, 1011, Not As Required, 14104, Oil Filtering Equipment, Pollution Prevention - Marpol Annex I, 1011, Not As Required, 07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required |