BoatDB
Vessel

CS TRUST

IMO 9438511
CargoBuilt 2009Active
CS TRUST — vessel photo
Photo: Rpvdk · CC BY-SA 3.0 · via Wikimedia Commons
14,030
Gross tonnageA measure of the vessel's total internal volume (not its weight).
13,189
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
436
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2009
Year built

Live position & voyage

LIVE
Loading position…

Shipments over time

bills of lading per month

Particulars

IMO
9438511
MMSI
566049000
Call sign
9V9353
Flag
SG
Type
Reefer
Length (LOA)
162.5 m
Beam
26 m
Home port

Ownership

Beneficial owner
Operator
Technical manager
Commercial manager
Class society
NK
Design DWT
13,189 t
Flag
Singapore
Built
2009

Timeline

key events over the vessel's life
  1. Dry dock
  2. Special survey
  3. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
22 May 2027
Special survey
22 May 2027
IOPP issued
24 Aug 2022
IOPP expires
22 May 2027

Top importers served

importers this vessel carried for

Shipments carried

recent bills of lading

Inspections

recent port state control
DatePortDetainedDeficiencies
06 Mar 2026ValparaisoNo4CERTIFICATE AND DOCUMENTATION - CREW CERTIFICATES (Endorsement By Flagstate) (03.03.2026) No 2 03102 WATER/WEATHERTIGHT CONDITIONS (Freeboard Marks) (03.03.2026) No 3 15109 ISM (Maintenance Of The Ship And Equipment) (07.07.2025) No 4 11101 LIFE SAVING APPLIANCES (Lifeboats) (03.03.2026)
03 Mar 2026ValparaisoNo41 01214 CERTIFICATE AND DOCUMENTATION - CREW CERTIFICATES (Endorsement By Flagstate) No 2 03102 WATER/WEATHERTIGHT CONDITIONS (Freeboard Marks) No 3 07110 FIRE SAFETY (Fire Fighting Equipment And Appliances) No 4 11101 LIFE SAVING APPLIANCES (Lifeboats) No
13 Feb 2026PhiladelphiaNo0
17 Dec 2025ZeebruggeNo1407105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required,02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required,18317, Food Personal Hygiene, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1025, Not Hygienic,18318, Food Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1023, Overheated,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required,14615, Fuel Change-Over Procedure, Pollution Prevention - Marpol Annex VI, 1011, Not As Required,10105, Magnetic Compass, Safety Of Navigation, 1161, Not Readable,13104, Bilge Pumping Arrangements, Propulsion And Auxiliary Machinery, 1011, Not As Required,04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1011, Not As Required,18429, Procedure For Inspection, Reporting And Correcting Unsafe Conditions And For Investigating And Reporting On-Board Occupational Accidents, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,07110, Fire Fighting Equipment And Appliances, Fire Safety, 1011, Not As Required,10105, Magnetic Compass, Safety Of Navigation, 1000, Missing,15150, ISM, ISM, 1011, Not As Required,10199, Other (Navigation), Safety Of Navigation, 1238, Other
07 Jul 2025OsakaNo411101 LIFE SAVING APPLIANCES (Lifeboats) No 2 11112 LIFE SAVING APPLIANCES (Launching Arrangements For Survival Craft) No 3 11135 LIFE SAVING APPLIANCES (Maintenance Of Life Saving Appliances) No 4 15109 ISM (Maintenance Of The Ship And Equipment)
16 Jan 2025ValparaisoNo1POLLUTION PREVENTION - MARPOL ANNEX V (Garbage)
15 Jan 2025ValparaisoNo31 01328 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Ship Energy Efficiency Management Plan) No 2 10127 SAFETY OF NAVIGATION (Voyage Or Passage Plan) No 3 14501 POLLUTION PREVENTION - MARPOL ANNEX V (Garbage) No
16 Jul 2024TaurangaNo710127 SAFETY OF NAVIGATION (Voyage Or Passage Plan) No 2 18499 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Other (Health Protection, Medical Care...)) No 3 11101 LIFE SAVING APPLIANCES (Lifeboats) No 4 09232 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Cleanliness Of Engine Room) No 5 09232 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Cleanliness Of Engine Room) No 6 18499 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Other (Health Protection, Medical Care...)) No 7 18499 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Other (Health Protection, Medical Care...)) No
31 Jan 2024San Pedro, CaliforniaNo8System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Component: 11129 - Operational Readiness Of Lifesaving Appliances Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Before The Ship Leaves And At All Times During The Voyage, All Life-Saving Appliances Shall Be In Working Order And Ready For Immediate Use. PSCO Observed 02 Of 03 Life Rafts With The Painter Line Plug Removed From Their Original Position. 74 SOLAS (20) III/ 20.2 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 2/1/2024 12:00:00 AM Resolution Description: Received Technicians Report Attesting To The Repair Of The 02 Life Raft'S Painter Plugs System: 15 - Safety Management Systems (ISM) Sub-System: N/A - No Subsystem Component: 15109 - Maintenance Of The Ship And Equipment Cause: Damaged By Earlier Event Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Cargo Ships Of 500 Gross Tonnage And Upwards, Not Later Than 1 July 2002, Shall Comply With The Requirements Of The International Safety Management Code. The Company Shall Ensure That: Any Non-Conformity Is Reported, With Its Probable Cause, If Known, Appropriate Corrective Action Is Taken, Records Of These Activities Are Maintained. The Company Shall Take Corrective Action Within 3 Months. 74 SOLAS (20) IX/ 2.1.3 ISM (2018) A/10.2 50ac Due Date: 4/30/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/4/2024 12:00:00 AM Resolution Description: N/A System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Component: 11135 - Maintenance Of Life Saving Appliances Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Instructions For On-Board Maintenance Of Life-Saving Appliances Shall Be Easily Understood, Illustrated Wherever Possible, And, As Appropriate, Shall Include The Following For Each Appliance; Log For Records Of Inspections And Maintenance. PSCO Observed On Both Lifeboats Putty Placed To Prevent Water Ingress. Repairs Using Putty Were Not Logged. 74 SOLAS (20) III/ 36.7 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 2/1/2024 12:00:00 AM Resolution Description: Received Technicians Report Attesting To The Repair Of Both Lifeboats System: 02 - Structural Conditions Sub-System: N/A - No Subsystem Component: 02199 - Other (Structural Condition) Cause: Improper/Lack Of Maintenance Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained To Conform With The Present Regulations To Ensure That The Ship In All Respects Will Remain Fit To Proceed To Sea Without Danger To The Ship Or Persons On Board. PSCO Observed The Forward Port Side Railing Being Bent And Damaged. 74 SOLAS (20) I/11 50ac Due Date: 3/1/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/4/2024 12:00:00 AM Resolution Description: N/A System: 02 - Structural Conditions Sub-System: N/A - No Subsystem Component: 02199 - Other (Structural Condition) Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Machinery, Boilers, And Other Pressure Vessels, Associated Piping Systems And Fittings Shall Be Of A Design And Construction Adequate For The Service For Which They Are Intended. PSCO Observed A Soft Patch On Fresh Water Line That Was Painted Over And Had A Catch Basin. 74 SOLAS (04) II-1/ 26.1 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 2/1/2024 12:00:00 AM Resolution Description: Received Technicians Report Attesting To The Repair Of The Fresh Water Line System: 03 - Water/Weathertight Conditions Sub-System: N/A - No Subsystem Component: 03104 - Cargo & Other Hatchways Cause: Improper/Lack Of Maintenance Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Means For Securing And Maintaining Weather Tightness Shall Be To Be Satisfaction Of The Administration. The Arrangements Shall Ensure That The Tightness Can Be Maintained In Any Sea Condition. PSCO Observed Multiple Cleats On The Forward Hatch As Not Serviceable. Load Lines 16 (4) Due Date: 3/1/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/4/2024 12:00:00 AM Resolution Description: N/A System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07126 - Oil Accumulation In Engine Room Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Or Flammable Liquid. For This Purpose, The Following Functional Requirements Shall Be Met; Means Shall Be Provided To Control Leaks Of Flammable Liquid. PSCO Observed The #2 Fuel Oil Circulator Leaking A Small Spray And Accumulating Oil In And Around The #1 And #2 Fuel Oil Circulators. 74 SOLAS (20) II-2/ 4.1.1 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 2/1/2024 12:00:00 AM Resolution Description: Received Technicians Report Attesting To The Repair Of #2 Fuel Oil Circulator System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07126 - Oil Accumulation In Engine Room Cause: Improper/Lack Of Maintenance Action: 10 - Deficiency Rectified Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Or Flammable Liquids, For This Purpose, The Following Functional Requirements Shall Be Met; Means Shall Be Provided To Control Leaks Of Flammable Liquid. PSCO Observed Oil Accumulation On The Cylinder Heads Of The Main Engine. 74 SOLAS (20) II-2/4.1.1 10c Due Date: N/A Deficiency Resolved? Yes Resolved Date: 1/31/2024 12:00:00 AM Resolution Description: N/A
10 Jan 2024ValparaisoNo0
12 Dec 2023SeteNo0
28 Aug 2023AucklandNo11 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) (07.06.2023) No
08 Jun 2023TaurangaNo0
07 Jun 2023TaurangaNo31 10116 SAFETY OF NAVIGATION (Nautical Publications) No 2 01307 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Minimum Hours Of Rest) No 3 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) No
04 Oct 2022DavaoNo0
06 Jan 2022AgadirNo1Propulsion And Auxiliary Machinery 13199 - Other (Machinery) Other
15 Jun 2021Port-VendresNo211134, Operation Of Life Saving Appliances, Life Saving Appliances, 1011, Not As Required, 18401, Medical Equipment, Medical Chest, Medical Guide, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,