Vessel
CYCLADES
IMO 9268485
CargoBuilt 2004Active
87,349
Gross tonnageA measure of the vessel's total internal volume (not its weight).
170,050
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
—
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2004
Year built
Live position & voyage
LIVELoading position…
Particulars
- IMO
- 9268485
- MMSI
- 636021947
- Call sign
- 5LGL7
- Flag
- LR
- Type
- Bulk Carrier
- Length (LOA)
- 288.97 m
- Beam
- 44.98 m
- Home port
- MONROVIA
Ownership
- Beneficial owner
- —
- Operator
- —
- Technical manager
- —
- Commercial manager
- —
- Class society
- CC
- Design DWT
- 170,050 t
- Flag
- Cyprus
- Built
- 2004
Timeline
key events over the vessel's life- Special survey
- Dry dock
- Built
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- 04 Jul 2027
- Special survey
- 13 May 2029
- IOPP issued
- 17 Jul 2024
- IOPP expires
- 13 May 2029
Shipments carried
recent bills of ladingNo shipment records.
Inspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 30 Apr 2025 | Singapore | No | 41 04114 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) (14.08.2023) No 2 14108 POLLUTION PREVENTION - MARPOL ANNEX I (15 PPM Alarm Arrangmts.) (14.08.2023) No 3 07101 FIRE SAFETY (Fire Prevention Structural Integrity) (14.08.2023) No 4 02199 STRUCTURAL CONDITIONS (Other (Structural Condition)) (14.08.2023) No |
| 30 Apr 2025 | Singapore | No | 31 11103 LIFE SAVING APPLIANCES (Stowage And Provision Of Lifeboats) No 2 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) No 3 07126 FIRE SAFETY (Oil Accumulation In Engine Room) No |
| 27 May 2024 | Tangshan | No | 41 04103 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) No 2 18401 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Medical Equipment, Medical Chest, Medical Guide) No 3 07110 FIRE SAFETY (Fire Fighting Equipment And Appli |
| 14 Aug 2023 | Guangzhou | No | 4EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) ; POLLUTION PREVENTION - MARPOL ANNEX I (15 PPM Alarm Arrangmts.) ; FIRE SAFETY (Fire Prevention Structural Integrity) ; STRUCTURAL CONDITIONS (Other (Structural Condition)) |
| 20 Jan 2023 | Qinhuangdao | No | 1CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Cargo Ship Safety Construction (Including Exempt.)) (15.12.2022) |
| 18 Dec 2022 | Walcott | No | 3Monitoring Of Voyage Or Passage Plan; Electrical; Cargo Ship Safety Construction (Including Exempt.) |
| 15 Dec 2022 | Port Walcott, WA | Yes | 4SAFETY OF NAVIGATION (Monitoring Of Voyage Or Passage Plan); LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Electrical); FIRE SAFETY (Other (Fire Safety)); CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Cargo Ship Safety Construc |