BoatDB
Vessel

DEDALOS

IMO 9487873
CargoBuilt 2010Active
51,209
Gross tonnageA measure of the vessel's total internal volume (not its weight).
93,038
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2010
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9487873
MMSI
215169000
Call sign
9HA4992
Flag
MT
Type
Bulk Carrier
Length (LOA)
229.17 m
Beam
38.05 m
Home port

Ownership

Beneficial owner
Operator
Lavinia Corp· Greece
Technical manager
Laskaridis Shipping
Commercial manager
Lavinia Corp
Class society
RI
Design DWT
93,038 t
Flag
Malta
Built
2010

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Casualty · Mechanical Fault
    Vsl disabled due to machinery failure, Vancouver Harbour, 31 May 2019. Anchored
  4. Sold
    $15.5M
  5. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
05 Apr 2028
Special survey
09 Feb 2030
IOPP issued
13 Apr 2025
IOPP expires
09 Feb 2030

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
23 Apr 2026BaltimoreNo2System: 04 - Emergency Systems Sub-System: N/A - No Subsystem Component: 04114 - Emergency Source Of Power - Emergency Generator Cause: Improper/Lack Of Maintenance Action: 60 - Rectify Deficiencies Prior To Movement Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: Emergency Generating Sets Shall Be Capable Of Being Readily Started In Their Cold Condition At A Temperature Of 0 Degrees Celsius. PSCO Observed Emergency Generator Having To Be Manually Adjusted To Start. 74SOLAS(24) II-I/44.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/26/2026 12:00:00 AM Resolution Description: Received Class Report Attesting To Proper Operation. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06105 - Atmosphere Testing Instruments Cause: Improper/Lack Of Maintenance Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: The Administration Shall Take Steps To Ensure That Crews Are Trained In Use Of Such Instruments. PSCO Identified Crew Using Incorrect Regulator For Gas Detection Equipment. 74 SOLAS (24) VI/3.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/26/2026 12:00:00 AM Resolution Description: Received Class Report Stating Proper Regulator Onboard.
25 Mar 2026RotterdamNo1501220, Seafarers' Employment Agreement (SEA), Certificate & Documentation - Crew Certificates, 1003, Not Properly Filled,07115, Fire-Dampers, Fire Safety, 1011, Not As Required,11124, Embarkation Arrangement Survival Craft, Life Saving Appliances, 1086, Not Properly Maintained,03105, Covers (Hatchway-, Portable-, Tarpaulins, Etc.), Water/Weathertight Conditions, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required,18427, Ship'S Occupational Safety And Health Policies And Programmes, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,02138, Decks � Construction, Structural Conditions, 1011, Not As Required,07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required,07106, Fire Detection And Alarm System, Fire Safety, 1000, Missing,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative,14104, Oil Filtering Equipment, Pollution Prevention - Marpol Annex I, 1082, Inoperative,02107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required,14616, Alternative Arrangements (SOx), Pollution Prevention - Marpol Annex VI, 1086, Not Properly Maintained,13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,18316, Water, Pipes, Tanks, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required
11 Aug 2025BoryeongNo21 02199 STRUCTURAL CONDITIONS (Other (Structural Condition)) No 2 14499 POLLUTION PREVENTION - MARPOL ANNEX IV (Other (MARPOL Annex IV)) No
24 Feb 2025TianjinNo410110 SAFETY OF NAVIGATION (Signalling Lamp) (22.02.2025) No 2 14499 POLLUTION PREVENTION - MARPOL ANNEX IV (Other (MARPOL Annex IV)) (22.02.2025) No 3 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) (22.02.2025) No 4 14402 POLLUTION P
22 Feb 2025TianjinNo41 10110 SAFETY OF NAVIGATION (Signalling Lamp) No 2 14499 POLLUTION PREVENTION - MARPOL ANNEX IV (Other (MARPOL Annex IV)) No 3 13103 PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) No 4 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) No
02 Jan 2024QuangninhNo0
28 Sep 2023Portsmouth, VirginiaNo1System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: The Machinery Boilers, And Other Pressure Vessles Associateed Piping Systems And Fittings Shall Be Of A Design An
18 Sep 2023RotterdamNo1507115, Fire-Dampers, Fire Safety, 1011, Not As Required, 01108, Load Lines (Including Exemption), Certificate & Documentation - Ship Certificates, 1086, Not Properly Maintained, 07103, Division - Decks,Bulkheads And Penetrations, Fire Safety, 1011, Not As Required, 03102, Freeboard Marks, Water/Weathertight Conditions, 1011, Not As Required, 02135, Beams, Frames, Floors – Construction, Structural Conditions, 1011, Not As Required, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 15150, ISM, ISM, 1011, Not As Required, 10135, Monitoring Of Voyage Or Passage Plan, Safety Of Navigation, 1011, Not As Required, 07120, Means Of Escape, Fire Safety, 1086, Not Properly Maintained, 08108, UMS - Alarms, Alarms, 1100, Malfunctioning, 18412, Personal Equipment, Labour Conditions - Health Protection, Medical Care, Social Security, 1000, Missing, 04113, Water Level Indicator, Emergency Systems, 1011, Not As Required, 07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe

Casualties

DateTypeDetails
31 May 2019Mechanical FaultVsl disabled due to machinery failure, Vancouver Harbour, 31 May 2019. Anchored with an assistance of tug. Crews carried repairs. Vsl was berthed in Vancouver & left the port 05 Jun, bound for Nakhodka ETA 22 Jun.

Sale & demolition history

reported transactions & recycling
DateEventPriceReported sale price in US$ millions.Buyer
02 Nov 2018 Reported Sold$15.5M