Vessel
DISNEY MAGIC
IMO 9126807
PassengerBuilt 1998Active

83,969
Gross tonnageA measure of the vessel's total internal volume (not its weight).
8,452
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
—
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
1998
Year built
Live position & voyage
LIVELoading position…
Particulars
- IMO
- 9126807
- MMSI
- 308516000
- Call sign
- C6PT7
- Flag
- BS
- Type
- Passenger Ship
- Length (LOA)
- 294.06 m
- Beam
- 32.29 m
- Home port
- NASSAU
Ownership
- Beneficial owner
- Walt Disney World· United States
- Operator
- Magical Cruise (Disney Cruise)· United States
- Technical manager
- Magical Cruise (Disney Cruise)
- Commercial manager
- Magical Cruise (Disney Cruise)
- Class society
- LR
- Design DWT
- 8,452 t
- Flag
- Bahamas
- Built
- 1998
Timeline
key events over the vessel's life- Special survey
- Dry dock
- Casualty · OtherVessel reported a leak originating from deck 5 worsened by March 30th, affecting
- Casualty · OtherOne passenger onboard had to be airlifted to hospital following medical emergenc
- Built
Engine
main engine & propulsion- Engine builder
- Wartsila Italia
- Designer
- Sulzer
- Designation
- 5 x 16ZAV40S
- Power (MCO)
- 58,250 kW
- RPM
- 510
- Propulsion
- MO
- Trading category
- Live
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- 25 Jun 2026
- Special survey
- 25 Jun 2028
- IOPP issued
- 10 Jun 2023
- IOPP expires
- 25 Jun 2028
Top importers served
importers this vessel carried forShipments carried
recent bills of ladingInspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 01 May 2026 | Vancouver | No | 314502, Placards, Pollution Prevention - Marpol Annex V, 1011, Not As Required,18313, Cleanliness, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,07116, Ventilation, Fire Safety, 1011, Not As Required |
| 24 Apr 2026 | Ensenada | No | 0 |
| 08 Mar 2026 | Texas City | No | 10System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Component: 11129 - Operational Readiness Of Lifesaving Appliances Cause: Damaged By Earlier Event Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Before The Ship Leaves Port And At All Times During The Voyage, All Life-Saving Appliances Shall Be In Working Order And Ready For Immediate Use. PSCO Observed Port Side Rescue Boat With Intermittent Gear Lever Engagement When Selecting Forward Gear. 74 SOLAS 20 III/20.2 Action Code 17c Def Code 11129 Due Date: 3/10/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Troubleshot And Identified Loose Throttle Cable Connection. Rectified And Retested Sat. System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Component: 11129 - Operational Readiness Of Lifesaving Appliances Cause: Design Flaw Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Before The Ship Leaves Port And At All Times During The Voyage, All Life-Saving Appliances Shall Be In Working Order And Ready For Immediate Use. PSCO Observed Several Lifeboats With Emergency Steering Tillers Incapable Of Steering The Lifeboat To Starboard. 74 SOLAS 20 III/20.2 Action Code 50c Def Code 11129 Due Date: 4/6/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/15/2026 12:00:00 AM Resolution Description: Class Report Attesting To Satisfactory Resolution Provided, Uploaded To Documents. System: 03 - Water/Weathertight Conditions Sub-System: N/A - No Subsystem Component: 03107 - Doors Cause: Design Flaw Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Each Power-Operated Sliding Watertight Door, Shall Be Provided With An Audible Alarm, Distinct From Any Other Alarm In The Area, Which Will Sound Whenever The Door Is Closed Remotely By Power And Which Shall Sound For At Least 5 S But Nounit. PSCO Observed Approximatley Half Of The Sliding Watertight Doors In Machinery Spaces With Inoperable Visual Signals 74 SOLAS 04 II-1/15.7.1.6 Action Code 16c Def Code 03107 Due Date: 3/10/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Replaced Bulbs And Retetested System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07123 - Operation Of Fire Protection Systems Cause: Damaged By Earlier Event Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Fire-Fighting Systems And Appliances Shall Be Kept In Good Working Order And Readily Available For Immediate Use. Portable Extinguishers Which Have Been Discharged Shall Be Immediately Recharged Or Replaced With An Equivalent Unit. PSCO Observed Stowed Items Blocking Sprinkler System Nozzles On Aft Mooring Deck. 74 SOLAS 20 II-2/14.2.1.2 Action Code 16c Def Code 07123 Due Date: 3/20/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Removed Stowed Gear Prior To Completion Of Exam. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07114 - Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces Cause: Design Flaw Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Means Of Control Shall Be Provided For Opening And Closure Of Skylights, Closure Of Openings In Funnels Which Normally Allow Exhaust Ventilation, And Closure Of Ventilator Dampers. PSCO Observed Labelling For Fire Damper Control System To Be Inaccurate. 74 SOLAS 97 II-2/11.4.1 Action Code 50c Def Code 07114 Due Date: 4/6/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Corrected Inaccurate Labelling On Damper. System Remains Inaccurate, However NCOE Stated That This Was Acceptable. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Design Flaw Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Construction Of All Doors And Door Frames In ``A'' Class Divisions, With The Means Of Securing Them When Closed, Shall Provide Resistance To Fire As Well As To The Passage Of Smoke And Flame, As Far As Practicable, Equivalent To That Of The Bulkheads In Which The Doors Are Situated. Such Doors And Door Frames Shall Be Constructed Of Steel Or Other Equivalent Material. PSCO Observed 12 Fire Doors, Including Those In Main Vertical Zone Boundaries Stairway Enclosures, Unable To Close Properly. 74 SOLAS 97 II-2/30.2 Action Code 17c Def Code 07105 Due Date: 3/10/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Rectified Each Identified Door Prior To Completion Of Exam System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07101 - Fire Prevention Structural Integrity Cause: Design Flaw Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Where The Contents And Use Of A Space Are Such That There Is A Doubt As To Its Classification For The Purpose Of This Regulation, It Shall Be Treated As A Space Within The Relevant Category Having The Most Stringent Boundary Requirements. PSCO Observed A/C Machinery Space On Deck 7 Converted Into Workshop, Including Storage Of Combustibles. 74 SOLAS 97 II-2/26.2.2 Action Code 50c Def Code 07101 Due Date: 4/6/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Removed All Items Stowed In A/C Machinery Space Prior To Completion Of Exam. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07120 - Means Of Escape Cause: Design Flaw Action: 50 - Rectify Deficiencies W/In 30 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Doorways, Cooridors, And Intermediate Landings Included In Means Of Escape Shall Be Sized In The Same Manner As Stairways. PSCO Observed Secondary Means Of Escape Door Form Category One Observation Center Was Smaller Than 800 Millimeters. 74 SOLAS 97 II-2/28.1.5.3 Action Code 50c Def Code 07120 Due Date: 4/30/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/15/2026 12:00:00 AM Resolution Description: Class Report Attesting To Satisfactory Resolution Provided, Uploaded To Documents. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07114 - Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces Cause: Design Flaw Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Means Of Control Shall Be Provided For Opening And Closure Of Skylights, Closure Of Openings In Funnels Which Normally Allow Exhaust Ventilation, And Closure Of Ventilation Dampers. PSCO Observed Ventilation Dampers 9304 And 04301 Not Close When Activated. 74 SOLAS 97 II-2/11.4.1 Action Code 16c Def Code 07114 Due Date: 3/20/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Troubleshot And Demonstrated Satisfactory Operation Of Dampers Prior To Completion Of Exam. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07101 - Fire Prevention Structural Integrity Cause: Design Flaw Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Where The Contents And Use Of A Space Are Such That There Is A Doubt As To Its Classification For The Purpose Of This Regulation, It Shall Be Treated As A Space Within The Relevant Category Having The Most Stringent Boundary Requirements. PSCO Observed Several Technical Spaces Behind Linings Being Used For Storage, Including Combustibles. 74 SOLAS 97 II-2/26.2.2 Action Code 16c Def Code 0701 Due Date: 3/20/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 3/6/2026 12:00:00 AM Resolution Description: Crew Removed Items Prior To Completion Of Exam. |
| 25 Sep 2023 | Miami Beach, Florida | No | 0 |
| 18 Jul 2023 | George Town | No | 0 |
| 20 Jun 2022 | Dubrovnik | No | 0 |
| 21 Mar 2022 | George Town | No | 1Means Of Escape |
| 05 Jul 2021 | Southampton | No | 418408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 01305, Log-Books/Compulsory Entries, Certificate & Documentation - Documents, 1002, Entries Missing, 07105, Fire Doors/Openings In Fire-Resisting Divisi |
Casualties
| Date | Type | Details |
|---|---|---|
| 29 Mar 2025 | Other | Vessel reported a leak originating from deck 5 worsened by March 30th, affecting decks 3, 4, and 5. Water fell near the main atrium’s chandelier lights, prompting closures, cancelled activities, and room changes for some passengers, who were compensated. The ship reached San Juan on March 31st. |
| 28 Jul 2021 | Other | One passenger onboard had to be airlifted to hospital following medical emergency. Vessel was on a 3-day cruise from Liverpool |