| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 14 Feb 2026 | Brownsville | No | 1System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Component: 13108 - Operation Of Machinery Cause: Placed In Improper Service Action: 60 - Rectify Deficiencies Prior To Movement Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Each Emergency Generating Set Arranged To Be Automatically Started Shall Be Equipped With Starting Devices Approved By Administration With A Stored Energy Capability Of At Least Three Consecutive Starts. A Second Source Of Energy Shall Be Used For An Additional Three Starts Within 30 Minutes Unless Manual Starting Can Be Demonstrated. PSCO Observed Emergency Generator Failed To Start. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 2/15/2026 12:00:00 AM Resolution Description: MSU Brownsville Received Class Report Noting New Batteries Replaced For Both Means Of Starting. PSCO Attended Vessel And Observed EGEN Start On Both Means. No Deficiencies Identified. |