Vessel
EXEED
IMO 9228033
CargoBuilt 2001Active
28,718
Gross tonnageA measure of the vessel's total internal volume (not its weight).
50,992
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
—
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2001
Year built
Live position & voyage
LIVELoading position…
Particulars
- IMO
- 9228033
- MMSI
- 352005584
- Call sign
- 3E8823
- Flag
- PA
- Type
- Bulk Carrier
- Length (LOA)
- 189.99 m
- Beam
- 32.26 m
- Home port
- VALLETTA
Ownership
- Beneficial owner
- Eli Shipping· China
- Operator
- Eli Shipping· China
- Technical manager
- Eli Shipping
- Commercial manager
- Eli Shipping
- Class society
- RI
- Design DWT
- 50,961 t
- Flag
- Panama
- Built
- 2001
Timeline
key events over the vessel's life- Dry dock
- Special survey
- Sold$6.2M
- Casualty · Engine FaultVessel experienced engine failure in lat 51 55 49N, long 003 24 48E, Rotterdam,
- Casualty · Beached/GroundedGrounded at Km 138, River Parana, opposite Nueva Palmira port, 28 Mar 2016. Obst
- Built
Engine
main engine & propulsion- Engine builder
- Kawasaki Heavy Industries
- Designer
- B&W
- Designation
- 6S50MC-C
- Power (MCO)
- 7,650 kW
- RPM
- 107
- Propulsion
- MO
- Trading category
- Live
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- 27 Apr 2027
- Special survey
- 27 Apr 2027
- IOPP issued
- 06 Mar 2024
- IOPP expires
- 27 Apr 2027
Top importers served
importers this vessel carried forShipments carried
recent bills of lading| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 27 Mar 2024 | Eurochem North America Corp | granular muriate of potash (gmop) in bulk | emml24cn14400x01 |
Inspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 28 Mar 2026 | Shanghai | No | 4STRUCTURAL CONDITIONS (Steering Gear ) (26.03.2026) Yes 2 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) (26.03.2026) Yes 3 04102 EMERGENCY SYSTEMS (Emergency Fire Pump And Its Pipes) (26.03.2026) Yes 4 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) (26.03.2026) |
| 26 Mar 2026 | Shanghai | Yes | 41 02105 STRUCTURAL CONDITIONS (Steering Gear ) Yes 2 03108 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) Yes 3 04102 EMERGENCY SYSTEMS (Emergency Fire Pump And Its Pipes) Yes 4 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) Yes |
| 19 Jan 2026 | Banten | No | 81 15106 ISM (Shipboard Operations) (12.11.2025) No 2 04103 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) (12.11.2025) No 3 14811 POLLUTION PREVENTION - BALLAST WATER (Ballast Water Management System) (12.11.2025) No 4 11119 LIFE SAVING APPLIANCES (Immersion Suits) (12.11.2025) No 5 07199 FIRE SAFETY (Other (Fire Safety)) (12.11.2025) No 6 14602 POLLUTION PREVENTION - MARPOL ANNEX VI (Record Book Of Engine Parameters) (12.11.2025) No 7 07106 FIRE SAFETY (Fire Detection And Alarm System) (12.11.2025) No 8 10103 SAFETY OF NAVIGATION (Radar) (12.11.2025) No |
| 19 Jan 2026 | Banten | No | 0 |
| 12 Nov 2025 | Dalian | No | 81 15106 ISM (Shipboard Operations) No 2 04103 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) No 3 14811 POLLUTION PREVENTION - BALLAST WATER (Ballast Water Management System) No 4 11119 LIFE SAVING APPLIANCES (Immersion Suits) No 5 07199 FIRE SAFETY (Other (Fire Safety)) No 6 14602 POLLUTION PREVENTION - MARPOL ANNEX VI (Record Book Of Engine Parameters) No 7 07106 FIRE SAFETY (Fire Detection And Alarm System) No 8 10103 SAFETY OF NAVIGATION (Radar) No |
| 17 Jul 2025 | Tianjin | No | 21 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (16.07.2025) No 2 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (16.07.2025) No |
| 16 Jul 2025 | Tianjin | No | 21 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) No 2 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) No |
| 23 Mar 2025 | Ashdod | No | 3Water/Weathertight Conditions 03103 - Railing, Gangway, Walkway And Means For Safe Passage Damaged Living And Working Conditions - Working Conditions 09299 - Other (Mooring) Damaged Safety Of Navigation 10116 - Nautical Publications Expired Total 0 0 0 0 |
| 27 Feb 2025 | Taman' | No | 1LIFE SAVING APPLIANCES (Stowage And Provision Of Lifeboats) (05.07.2024) Rectify Deficiency At Next Port Deficiency Rectified |
| 23 Sep 2024 | Port Of Onne | No | 0 |
| 05 Jul 2024 | Novorossiisk | No | 4EMERGENCY SYSTEMS (Water Level Indicator) ; LIFE SAVING APPLIANCES (Inflatable Liferaft ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Winches & Capstans) ; LIFE SAVING APPLIANCES (Stowage And Provision Of Lifeboats) |
| 27 Mar 2024 | New Orleans | No | 0 |
| 09 Feb 2024 | Nowy Port/Gdansk | No | 218408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe,01315, Oil Record Book, Certificate & Documentation - Documents, 1011, Not As Required |
| 08 May 2023 | Lake Charles | No | 7System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: Each Liferaft Or Group Of Liferafts Shall Be Stowed With A Float Free Arrangement Complying With The Requirements Of Paragraph 4.1.6 Of The Code So That Each Floats Free. Liferaft Painter Line Was Not Shackled To The Weak Link Preventing Float Free Arrangement. 74 SOLAS Amend. 2020 Chapter III/13.4.2 10c Due Date: 5/9/2023 5:00:00 AM Deficiency Resolved? Yes Resolved Date: 5/9/2023 12:00:00 AM Resolution Description: N/A System: 15 - Safety Management Systems (ISM) Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: Every Company Should Develop, Implement, And Maintain A Safety Management System Which Includes The Following Functional Requirements: Instructions And Procedures To Ensure Safe Operation Of Ships And Protection Of The Environment In Compliance With Relevant International And Flag State Legislation. Due To Deficiencies Noted, The Vessel Is Unable To Comply With Environmental Protection Policies Which Presents A Pollution Hazard. Provide Corrective Action Plan And Failure Analysis With Concurrence From Class And Flag State. Vessel Shall Be Audited And Results Forwarded To Coast Guard. ISM Code 1.4 50ac Due Date: 6/9/2023 12:00:00 AM Deficiency Resolved? No Resolved Date: N/A Resolution Description: N/A System: 14 - Pollution Prevention Sub-System: 141 - MARPOL Annex I Cause: Description Of Deficiency: Oil Filtering Equipment Referred To In Paragraph 1 Of This Regulation Shall Be Of A Design Approved By The Administration And Shall Be Such As Will Ensure That Any Oily Mixture Discharged Into The Sea After Passing Through The System Has An Oil Content Not Exceeding 15 Parts Per Million. Oily Water Separator Would Not Run Continuously For More Than 2 Minutes Without Bilge Pump Losing Suction From Bilge Tank. Pump Would Only Run With Supply Water From Sea Chest Opened. 2017 MARPOL ANNEX I Reg 14/6 30ac Due Date: 5/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 5/12/2023 12:00:00 AM Resolution Description: Received Class Report Satisfying The Requirements. System: 15 - Safety Management Systems (ISM) Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: The Company Shall Establish Procedures To Ensure That The Ship Is Maintained In Conformity With The Provisions Of The Relevant Rules And Regulations And With Any Additional Requirements Which May Be Established By The Company. Oil Content Meter Manual States Clock Batteries Shall Be Replaced Every 2 Years. Batteries Are Overdue And SMS Does Not Include Replacement Intervals. ISM Code 10.1 50c Due Date: 6/9/2023 12:00:00 AM Deficiency Resolved? No Resolved Date: N/A Resolution Description: N/A System: 01 - Certificates & Documentation Sub-System: 013 - Documents Cause: Description Of Deficiency: The Oil Record Book Part I Shall Be Completed On Each Occasion, On A Tank-To-Tank Basis If Appropriate, Whenever Any Of The Following Machinery Space Operations Takes Place In The Ship: Discharge Overboard Or Disposal Otherwise Of Bilge Water Which Has Accumulated In Machinery Spaces. On 06 Mar 2023, C/E Recorded Running OWS For 4 Hours And Discharging 8 Cubic Meters Overboard. Oil Content Meter (OCM) History Only Shows OWS Running For Approximately 30 Minutes. 2017 MARPOL ANNEX I Reg 17/2.4 30ac Due Date: 5/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 5/12/2023 12:00:00 AM Resolution Description: Received Class Report Satisfying The Requirements. System: 01 - Certificates & Documentation Sub-System: 013 - Documents Cause: Description Of Deficiency: The Oil Record Book Part I Shall Be Completed On Each Occasion, On A Tank-To-Tank Basis If Appropriate, Whenever Any Of The Following Machinery Space Operations Takes Place In The Ship: Discharge Overboard Or Disposal Otherwise Of Bilge Water Which Has Accumulated In Machinery Spaces. On 17 Apr 2023, ORB States OWS Running For 2hr 10mins With A Total Of 6 Cubic Meters Throughput Which Exceeded Their Maximum Possible Throughput Of 2 Cubic Meters Per Hour. OCM Verified Run Time Of Approximately 2 Hours. 2017 MARPOL ANNEX I Reg 17/2.4 30ac Due Date: 5/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 5/12/2023 12:00:00 AM Resolution Description: Received Class Report Satisfying The Requirements. System: 01 - Certificates & Documentation Sub-System: 013 - Documents Cause: Description Of Deficiency: The Oil Record Book Part I Shall Be Completed On Each Occasion, On A Tank-To-Tank Basis If Appropriate, Whenever Any Of The Following Machinery Space Operations Takes Place In The Ship: Discharge Overboard Or Disposal Otherwise Of Bilge Water Which Has Accumulated In Machinery Spaces. On 17 Mar 2023, OCM Shows OWS Run For Approximately 1.5 Hours With No Corresponding Entry Into The Oil Record Book Part I. C/E Stated He Ran The OWS And Did Not Enter In ORB. 2017 MARPOL ANNEX I Reg 17/2.4 30ac Due Date: 5/9/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 5/12/2023 12:00:00 AM Resolution Description: Received Class Report Satisfying The Requirements. |
| 02 Dec 2022 | Laurium (Lavrion) | No | 0 |
| 03 Oct 2022 | Ashdod | No | 2Fire Safety, 07110 - Fire Fighting Equipment And Appliances, Not As Required Living And Working Conditions - Living Conditions, 09112 - Medical Equipment, Missing Equipment |
| 01 Sep 2021 | Klaipeda | No | 0 |
Casualties
| Date | Type | Details |
|---|---|---|
| 03 Feb 2021 | Engine Fault | Vessel experienced engine failure in lat 51 55 49N, long 003 24 48E, Rotterdam, Netherlands, 03 Feb 2021. Repairs completed & continued its voyage. Ar in the Port of Dordrecht, Netherlands, 03 Feb. |
| 28 Mar 2016 | Beached/Grounded | Grounded at Km 138, River Parana, opposite Nueva Palmira port, 28 Mar 2016. Obstructing navigation. Refloated 31 Mar with tug assistance & to proceed to Km 171, River Parana, for inspections. |
Sale & demolition history
reported transactions & recycling| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 28 Apr 2025 | Reported Sold | $6.2M | Unknown |