BoatDB
Vessel

F LINE

IMO 9320324
CargoBuilt 2007Active
19,918
Gross tonnageA measure of the vessel's total internal volume (not its weight).
30,600
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2007
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9320324
MMSI
314738000
Call sign
8PKO9
Flag
BB
Type
General Cargo
Length (LOA)
178.76 m
Beam
28.06 m
Home port
NASSAU

Ownership

Beneficial owner
Iskele Denizcilik Ticaret· Turkey
Operator
Iskele Denizcilik Ticaret· Turkey
Technical manager
Iskele Denizcilik Ticaret
Commercial manager
Iskele Denizcilik Ticaret
Class society
TL
Design DWT
30,587 t
Flag
Bahamas
Built
2007

Timeline

key events over the vessel's life
  1. Dry dock
  2. Special survey
  3. Sold
    $7.5M
  4. Casualty · Engine Fault
    Had engine failure abt 600 nautical miles from Kashima, in abt 29 46 N 150 20 E,
  5. Built

Engine

main engine & propulsion
Engine builder
STX Engine
Designer
MAN B&W
Designation
6S42MC-MKVII
Power (MCO)
6,389 kW
RPM
131
Propulsion
MO
Trading category
Live

Surveys & certificates

dry dock & statutory certificates
Last dry dock
13 Mar 2026
Special survey
13 Mar 2026
IOPP issued
27 Apr 2024
IOPP expires
04 Feb 2026

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
13 May 2026BatumiNo61 FIRE SAFETY (Maintenance Of Fire Protection Systems) Rectify Deficiency Within 14 Days 2 EMERGENCY SYSTEMS (Water Level Indicator) Rectify Deficiency Before Departure Deficiency Rectified 3 LIFE SAVING APPLIANCES (Operational Readiness Of Lifesaving Appliances) Rectify Deficiency Before Departure Deficiency Rectified 4 FIRE SAFETY (Means Of Escape) Rectify Deficiency Before Departure Deficiency Rectified 5 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Obstruction/Slipping, Etc.) Rectify Deficiency At Next Port 6 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Other (Accident Prevention)) Rectify Deficiency Before Departure Deficiency Rectified
13 Apr 2026OranNo0
13 Oct 2025CasablancaNo0
09 Sep 2025HaifaNo0
22 Apr 2025CabezuelaNo201309, Fire Control Plan - All, Certificate & Documentation - Documents, 1112, Wrong Information,07106, Fire Detection And Alarm System, Fire Safety, 1086, Not Properly Maintained
09 Nov 2024MtwaraNo0
02 Jun 2024GresikNo0
05 Nov 2023Lavrion (Laurium)No5Voyage Data Recorder (VDR) / Simplified Voyage Data Recorder (S-VDR) Not As Required ; Lifeboats Not Ready For Use ; Emergency Fire Pump And Its Pipes Not As Required ; Oil Filtering Equipment Not As Required ; ISM Not As Required
09 Aug 2023TamanNo12LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Steam Pipes, Pressure Pipes, Wires (Insulation)) ; SAFETY OF NAVIGATION (Voyage Data Recorder (VDR)/Simplified Voyage Data Recorder(S-VDR)) ; LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Lighting (Accommodation)) ; ALARMS (Machinery Controls Alarm) ; SAFETY OF NAVIGATION (Compass Correction Log) ; STRUCTURAL CONDITIONS (Decks - Corrosion) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Protection Machinery) ; WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) ; WATER/WEATHERTIGHT CONDITIONS (Covers (Hatchway-, Portable-, Tarpaulins, Etc.)) ; FIRE SAFETY (Maintenance Of Fire Protection Systems) ; EMERGENCY SYSTEMS (Enclosed Space Entry And Rescue Drills) ; FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions)
20 Jun 2023DamiettaNo2Safety Of Navigation - Other (Navigation) Other ; Emergency Systems - Emergency Source Of Power - Emergency Generator Not As Required
20 Jun 2023HaifaNo4Fire Safety - Fixed Fire Extinguishing Installation;Alarms - Other (Alarms); Living And Working Conditions - Working Conditions - Electrical; Fire Safety - Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces
12 Jan 2023NovorossiiskNo171 LABOUR CONDITIONS-CONDITIONS OF EMPLOYMENT (Fitness For Duty - Work And Rest Hours) (12.07.2022) Other (Specify) Deficiency Rectified 2 SAFETY OF NAVIGATION (Compass Correction Log) (12.07.2022) Other (Specify) 3 RADIO COMMUNICATIONS (Radio Log (Diary)) (12.07.2022) Other (Specify) Deficiency Rectified 4 STRUCTURAL CONDITIONS (Decks - Corrosion) (12.07.2022) Other (Specify) 5 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Protection Machinery) (12.07.2022) Rectify Deficiency Before Departure 6 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Electrical) (12.07.2022) Rectify Deficiency Before Departure Deficiency Rectified 7 STRUCTURAL CONDITIONS (Steering Gear ) (12.07.2022) Rectify Deficiency Before Departure Deficiency Rectified 8 LIFE SAVING APPLIANCES (On Board Training And Instructions) (12.07.2022) Rectify Deficiency Before Departure Deficiency Rectified 9 ISM (ISM) (12.07.2022) Corrective Action Taken On The ISM System By The Company Is Required Within 3 Months Deficiency Rectified 10 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Steam Pipes, Pressure Pipes, Wires (Insulation)) Other (Specify) 11 WATER/WEATHERTIGHT CONDITIONS (Cargo & Other Hatchways) Rectify Deficiency Before Departure Deficiency Rectified 12 FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) Rectify Deficiency Before Departure Deficiency Rectified 13 SAFETY OF NAVIGATION (Voyage Data Recorder (VDR)/Simplified Voyage Data Recorder(S-VDR)) Rectify Deficiency At Next Port 14 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Lighting (Accommodation)) Rectify Deficiency Within 14 Days 15 FIRE SAFETY (Fire Detection And Alarm System) Rectify Deficiency Before Departure Deficiency Rectified 16 ALARMS (Machinery Controls Alarm) Rectify Deficiency Before Departure Deficiency Rectified 17 ALARMS (Machinery Controls Alarm) Rectify Deficiency At Next Port
04 Sep 2022HaifaNo4Fire Safety - Fixed Fire Extinguishing Installation;Alarms - Other (Alarms); Living And Working Conditions - Working Conditions - Electrical; Fire Safety - Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces
12 Jul 2022ConstantzaNo918201, Fitness For Duty - Work And Rest Hours, Labour Conditions - Conditions Of Employment, 1011, Not As Required, 10106, Compass Correction Log, Safety Of Navigation, 1011, Not As Required, 05115, Radio Log (Diary), Radio Communications, 1011, Not As Required, 02117, Decks - Corrosion, Structural Conditions, 1011, Not As Required, 18414, Protection Machines/Parts, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 02105, Steering Gear, Structural Conditions, 1086, Not Properly Maintained, 11131, On Board Training And Instructions, Life Saving Appliances, 1052, Missing Instructions, 15150, ISM, ISM, 1011, Not As Required,
07 Jul 2021AntalyaYes8Cleanliness Of Engine Room; Operation Of Machinery; Propulsion Main Engine; Distress Messages : Obligations And Procedures; Engineers' Alarm; Other (Alarms); Other (Machinery); Record Of Drills And Test Steering Gear
07 Jul 2021AntalyaYes0

Casualties

DateTypeDetails
13 Nov 2015Engine FaultHad engine failure abt 600 nautical miles from Kashima, in abt 29 46 N 150 20 E, 13 Nov 2015. Subsequently reported in 34 18.8 N 129 8 19.14 E 24 Nov, not under command. Towed to Busan 25 Nov & entered shipyard.

Sale & demolition history

reported transactions & recycling
DateEventPriceReported sale price in US$ millions.Buyer
01 Mar 2023 Reported SoldBWTS fitted$7.5M