| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 06 Jun 2023 | Morgan City, Louisiana | No | 13System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Cause: Placed In Improper Service Description Of Deficiency: A Power Driven Vessel Underway Shall Exhibit A Stern Light. Vessel'S Stern Light Was Fully Obstructed By Vessel Stowed On Deck. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Stern Light Moved Higher Up On The Pilot House System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: A Vessel At Anchor Shall Exhibit... An All Around White Light. Vessel'S Anchor Light Was Not Functional. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Light Replaced System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: A Vessel Of 12 Meters Or More... Shall Be Provided With A Whistle. Ship'S Whistle Does Not Function. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Diaphragm Replaced In Ships Whistle. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Damaged By Earlier Event Description Of Deficiency: All Piping, Valves And Fittings Shall Meet The Applicable Requirements Of Subchapter F. Fireman Was Weathering And Compromised With A Hole. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Fire Main Repaired System: 01 - Certificates & Documentation Sub-System: 012 - Crew Certificates Cause: Invalid Description Of Deficiency: Each Administration Shall Ensure That The Provisions Of This Regulation Are Complied With, In Order To Recognize, By Endorsement In Accordance With Regulation I/2, Paragraph 7, A Certificate Issued By Or Under The Authority Of Another Party. No Flag State Endorsements Were Held By Any Of The Certificated Officers. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: N/A System: 05 - Radio Communications Sub-System: N/A - No Subsystem Cause: Improper Installation Description Of Deficiency: Every Ship Engaged On Voyages Beyond Sea Areas A1 And A2, But Remaining Within Sea Area A3 Be Provided With Inmarsat Earth Radio.... Vessel Does Not Have A GMDSS Radio Station Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Class Approved Vessel To Sail One Time Without GMDSS System: 05 - Radio Communications Sub-System: N/A - No Subsystem Cause: Invalid Description Of Deficiency: Every Ship Shall Be Provided With A VHF Radio Capable Of Transmitting And Receiving DSC... Vessel Did Not Have A Long Range Radio Capable Of DSC. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: MF Dsc Capable Radio Installed System: 01 - Certificates & Documentation Sub-System: 011 - Ships Certificates Cause: Improper Installation Description Of Deficiency: International Load Line Certificate Shall Not Be Delivered To The Ship Until The Officer Or Surveyor Acting Under The Provisions Of Article 13 Of The Convention Has Certified That The Marks Are Correctly And Permanently Indicated On The Ships Sides. Ship'S Load Lines And Plimsoll Mark Are Not Properly Reflected From The Certificate. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Load Lines Marked Properly In Accordance With ILLC System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: The Installation Of All Systems Of A Marine Engineering Nature, Together With Details Of Design... Shall Be In Accordance With The Requirements Of Subchapter F. Engine Is Not Drawing Water In Order To Keep The System Cooling. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Sea Strainers Cleaned, Allowing More Cooling Water Through System System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: The Installation Of All Systems Of A Marine Engineering Nature, Together With Details Of Design... Shall Be In Accordance With The Requirements Of Subchapter F. Vessel'S Exhaust Bracket Crack. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Bracket Welded System: 13 - Propulsion And Auxiliary Machinery Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: The Installation Of All Systems Of A Marine Engineering Nature, Together With Details Of Design... Shall Be In Accordance With The Requirements Of Subchapter F. Vessel'S STBD Diesel Generator Had Major Fuel Leak. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Leak Repaired System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Cause: Improper Installation Description Of Deficiency: The Installations Of All Life Saving Appliances And Arrangements Must Be In Accordance With Subchapter W. Life Raft Not Installed In Proper Float Free Arrangement. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: Liferaft Cradle Properly Fixed To The Deck System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Cause: Placed In Improper Service Description Of Deficiency: Vessels Under 200 Feet Maybe Equipped With Either One Anchor And One Half Length Of Anchor Chain Listed In The Applicable Standard. Vessel'S Didn'T Have And Anchor Line Ready. Due Date: N/A Deficiency Resolved? Yes Resolved Date: 9/12/2023 12:00:00 AM Resolution Description: New Anchor Line Brought Onboard |