Vessel
FINEX
IMO 9250397
CargoBuilt 2002Active

6,378
Gross tonnageA measure of the vessel's total internal volume (not its weight).
9,900
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
552
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2002
Year built
Live position & voyage
LIVELoading position…
Particulars
- IMO
- 9250397
- MMSI
- 375068000
- Call sign
- J8B6649
- Flag
- VC
- Type
- General Cargo
- Length (LOA)
- 132.2 m
- Beam
- 15.87 m
- Home port
- BASSETERRE
Ownership
- Beneficial owner
- —
- Operator
- —
- Technical manager
- Sarfo Denizcilik
- Commercial manager
- —
- Class society
- BV
- Design DWT
- 9,822 t
- Flag
- St.Kitts And Nevis
- Built
- 2001
Timeline
key events over the vessel's life- Dry dock
- Special survey
- Casualty · Detained/ArrestedShe was detained by Finnish police on suspicion of damaging an undersea telecomm
- Built
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- 28 Feb 2027
- Special survey
- 28 Feb 2027
- IOPP issued
- 19 Jul 2022
- IOPP expires
- 28 Feb 2027
Shipments carried
recent bills of ladingNo shipment records.
Inspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 01 Apr 2026 | Tuapse | No | 5LIFE SAVING APPLIANCES (Inflatable Liferafts) Rectify Deficiency Before Departure Deficiency Rectified FIRE SAFETY (Fixed Fire Extinguishing Installation) Rectify Deficiency Before Departure Deficiency Rectified LIFE SAVING APPLIANCES (Lifeboats) Rectify Deficiency Before Departure Deficiency Rectified CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Log-Books/Compulsory Entries) Rectify Deficiency Before Departure Deficiency Rectified SAFETY OF NAVIGATION (Monitoring Of Voyage Or Passage Plan) Rectify Deficiency Before Departure Deficiency Rectified |
| 01 Jan 2026 | Kantvik | No | 1004114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1000, Missing,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1000, Missing,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1026, Damaged,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1082, Inoperative,07199, Other (Fire Safety), Fire Safety, 1238, Other,07101, Fire Prevention Structural Integrity, Fire Safety, 1011, Not As Required,07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1082, Inoperative,02199, Other (Structural Conditions), Structural Conditions, 1238, Other,03108, Ventilators, Air Pipes, Casings, Water/Weathertight Conditions, 1086, Not Properly Maintained,18420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required |
| 11 Sep 2025 | Iskenderun | No | 3Pollution Prevention - Ballast Water 14801 - Ballast Water Management Plan Not Updated Safety Of Navigation 10111 - Charts Expired Pollution Prevention - Marpol Annex I 14104 - Oil Filtering Equipment Not As Required |
| 22 Apr 2025 | Bayonne | No | 4Labour Conditions - Health Protection, Medical Care, Social Security 18420 - Cleanliness Of Engine Room Not As Required Labour Conditions - Health Protection, Medical Care, Social Security 18420 - Cleanliness Of Engine Room Not As Required Labour Conditions - Accommodation, Recreational Facilities, Food And Catering 18302 - Sanitary Facilities Not As Required Labour Conditions - Accommodation, Recreational Facilities, Food And Catering 18304 - Lighting (Accommodation) Inoperative |
| 27 Jan 2025 | Foynes | No | 2Certificate & Documentation - Crew Certificates; 01218 - Medical Certificate Expired; Safety Of Navigation; 10105 - Magnetic Compass; Not Readable |
| 19 Nov 2024 | Novorossiisk | No | 31 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) Rectify Deficiency Before Departure Deficiency Rectified 2 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Medical Equipment, Medical Chest, Medical Guide) Recti |
| 27 Oct 2024 | Haifa | No | 3Propulsion And Auxiliary Machinery 13102 - Auxiliary Engine Not As Required Fire Safety 07109 - Fixed Fire Extinguishing Installation Not As Required Living And Working Conditions - Working Conditions 09232 - Cleanliness Of |
| 04 Dec 2023 | Brake | No | 2Fire Safety; 07111 - Personal Equipment For Fire Safety; Not As Required Fire Safety; 07106 - Fire Detection And Alarm System; Not As Required |
| 21 Oct 2023 | Novorossiisk | No | 2LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship)) ; ALARMS (Machinery Controls Alarm) |
| 04 May 2023 | Haifa | No | 12Safety Of Navigation - Nautical Publications Missing ; Fire Safety - Fire Detection And Alarm System Inoperative ; Living And Working Conditions - Living Conditions - Medical Equipment Missing Equipment ; Radio Communications - Facilities For Reception Of Marine Safety Inform. Not As Required ; Fire Safety - Fixed Fire Extinguishing Installation Not As Required ; Fire Safety - Evaluation Of Crew Performance (Fire Drills) Lack Of Familiarity ; Propulsion And Auxiliary Machinery - Other (Machinery) Other ; Emergency Systems - Means Of Communication Between Safety Centre And Other Control Stations Inoperative ; Fire Safety - Other (Fire Safety) Other ; Emergency Systems - Emergency Source Of Power - Emergency Generator Inoperative ; Propulsion And Auxiliary Machinery - Auxiliary Engine Not Approved ; ISM - ISM Not As Required |
| 24 Oct 2022 | Rostock | No | 1514802, Ballast Water Record Book, Pollution Prevention - Ballast Water, 1003, Not Properly Filled, 05118, Operation Of GMDSS Equipment, Radio Communications, 1208, Lack Of Familiarity, 04109, Fire Drills, Emergency Systems, 1207, Lack Of Knowledge, 18313, Cleanliness, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1025, Not Hygienic, 11101, Lifeboats, Life Saving Appliances, 1047, Not Ready For Use, 07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1000, Missing, 11110, Stowage And Provision Of Liferafts, Life Saving Appliances, 1011, Not As Required, 11104, Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 15150, ISM, ISM, 1011, Not As Required, 11124, Embarkation Arrangement Survival Craft, Life Saving Appliances, 1082, Inoperative, 18418, Winches & Capstans, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 02117, Decks - Corrosion, Structural Conditions, 1026, Damaged, 18401, Medical Equipment, Medical Chest, Medical Guide, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18315, Provisions Quality And Nutritional Value, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 0 |
| 27 Sep 2022 | Alexandria | No | 3VHF Radio Installation Not As Required; SOPEP Not Updated; Auxiliary Engine Not As Required |
| 11 Mar 2022 | Venezia | No | 6Other, Other, Other, Other, Other, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1011, Not As Required, 07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required, 01220, Seafarers' Employment Agreement (SEA), Certificate & Documentation - Crew Certificates, 1004, Expired, 03103, Railing, Gangway, Walkway And Means For Safe Passage, Water/Weathertight Conditions, 1086, Not Properly Maintained, 04109, Fire Drills, Emergency Systems, 1091, Lack Of Training, |
| 31 Jan 2022 | Kocaeli | No | 4Magnetic Compass Not As Required; Gangway, Accommodation-Ladder Unsafe; Steering Gear Alarm Malfunctioning; Other (Navigation) Other |
| 12 Aug 2021 | Gent (Ghent) | No | 1402105, Steering Gear, Structural Conditions, 1011, Not As Required, 07111, Personal Equipment For Fire Safety, Fire Safety, 1086, Not Properly Maintained, 08108, UMS - Alarms, Alarms, 1075, Inadequate, 01220, Seafarers' Employment Agreement (SEA), Certificate & Documentation - Crew Certificates, 1004, Expired, 15150, ISM, ISM, 1011, Not As Required, 11108, Inflatable Liferafts, Life Saving Appliances, 1004, Expired, 01330, Procedure For Complaint Under MLC,2006, Certificate & Documentation - Documents, 1031, Incomplete, 11102, Lifeboat Inventory, Life Saving Appliances, 1031, Incomplete, 11104, Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1082, Inoperative, 03108, Ventilators, Air Pipes, Casings, Water/Weathertight Conditions, 1011, Not As Required, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1011, Not As Required,, 0 |
| 15 Feb 2021 | Szczecin | No | 0 |
Casualties
| Date | Type | Details |
|---|---|---|
| 31 Dec 2025 | Detained/Arrested | She was detained by Finnish police on suspicion of damaging an undersea telecommunications cable owned by Elisa while en route from St. Petersburg to Haifa. All 14 crew members were arrested, and authorities are investigating the incident as "aggravated sabotage" and "aggravated disruption of telecommunications." Service was re-routed and remains functional. |