Loading…

| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 01 Dec 2025 | Esbjerg | No | 1101220, Seafarers' Employment Agreement (SEA), Certificate & Documentation - Crew Certificates, 1011, Not As Required,01123, Continuous Synopsis Record, Certificate & Documentation - Ship Certificates, 1000, Missing,01142, Liability For The Removal Of Wrecks Certificate, Certificate & Documentation - Ship Certificates, 1000, Missing,10109, Lights, Shapes, Sound-Signals, Safety Of Navigation, 1011, Not As Required,11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 1046, Not Properly Marked,11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 1011, Not As Required,11117, Lifebuoys Incl. Provision And Disposition, Life Saving Appliances, 1000, Missing,07118, International Shore-Connection, Fire Safety, 1011, Not As Required,07112, Emergency Escape Breathing Device And Disposition, Fire Safety, 1045, Not Properly Stowed,02105, Steering Gear, Structural Conditions, 1011, Not As Required,18414, Protection Machines/Parts, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required |
| 05 Sep 2024 | Zeebrugge | No | 10Seafarers' Employment Agreement (SEA) Not As Required ; Liability For The Removal Of Wrecks Certificate Missing ; Civil Liability For Oil Pollution Damage Cert. Missing ; Civil Liability For Bunker Oil Pollution Damage Cert Missing ; Certificates For Master And Officers Missing ; ISM Not As Required ; Bilge Pumping Arrangements Not As Required ; Inflatable Liferafts Incomplete ; Ballast Water Record Book Not Properly Filled ; Public Address System Inoperative |
| 30 Jun 2023 | Zeebrugge | No | 9Record Of Drills And Steering Gear Tests Not As Required ; Other (Certificates) Other ; Heating, Air Conditioning And Ventilation Not As Required ; Emergency Source Of Power - Emergency Generator Not As Required ; Wages Missing Information ; Nautical Publications Not Updated ; Food Temperature Not As Required ; On Board Training And Instructions Missing Instructions ; Emergency Fire Pump And Its Pipes Not As Required |
| 02 Aug 2022 | Gibraltar | No | 218499, Other (Health Protection, Medical Care), Labour Conditions - Health Protection, Medical Care, Social Security, 1238, Other, 04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1011, Not As Required, |