Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 07 Aug 2025 | Antwerpen | No | 1514802, Ballast Water Record Book, Pollution Prevention - Ballast Water, 1002, Entries Missing,14811, Ballast Water Management System, Pollution Prevention - Ballast Water, 1086, Not Properly Maintained,14602, Record Book Of Engine Parameters, Pollution Prevention - Marpol Annex VI, 1011, Not As Required,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative,10116, Nautical Publications, Safety Of Navigation, 1000, Missing,14108, 15 PPM Alarm Arrangmts., Pollution Prevention - Marpol Annex I, 1011, Not As Required,10109, Lights, Shapes, Sound-Signals, Safety Of Navigation, 1011, Not As Required,04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1086, Not Properly Maintained,07109, Fixed Fire Extinguishing Installation, Fire Safety, 1082, Inoperative,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required,07116, Ventilation, Fire Safety, 1011, Not As Required,11110, Stowage And Provision Of Liferafts, Life Saving Appliances, 1064, HRU Improp. Fitted,13104, Bilge Pumping Arrangements, Propulsion And Auxiliary Machinery, 1011, Not As Required,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required |
| 04 Jul 2024 | Corpus Christi | No | 0 |
| 30 Mar 2024 | Corpus Christi | No | 5System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07109 - Fixed Fire Extinguishing Installation Cause: Action: 10 - Deficiency Rectified Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Fire Protection Systems And Fire-Fighting Systems And Appliances Shall Be Maintained Ready For Use. CO2 Release Cabinet Door Outside Compressor Room And Motor Room Seized Shut. 74SOLAS(09) II-2/14.1.1 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 3/30/2024 12:00:00 AM Resolution Description: Crew Fixed Both CO2 Release Cabinets Prior To End Of Exam. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06105 - Atmosphere Testing Instruments Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Gas Detection Equipment Acceptable To The Administration And Suitable For The Gasses To Be Carried. Vessel Is Loading VCM And Does Not Have A Means To Test For VCM Gas. 74SOLAS(09) VII/13.1 IGC 93' 13.6.1 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/5/2024 12:00:00 AM Resolution Description: Vessel Received 40 VCM Draeger Tubes. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07199 - Other (Fire Safety) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: In Tankers, Electrical Equipment, Cables And Wiring Shall Not Be Installed In Hazardous Locations Unless It Conforms With Standards Not Inferior To Those Acceptable To The Organization. 06 Explosion Proof Lights Were Found Cracked In The Cargo Compressor Room. Recommend Inspecting All Lights. 02 Explosion Proof Lights Were Found Cracked In The Motor Room And Did Not De-Energize With Loss Of Overpressure From Air Lock. Recommend Inspecting All Lights. 74SOLAS(09) II-2/45.11 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/13/2024 12:00:00 AM Resolution Description: Class Has Given The Vessel 30 Days To Rectify IAW With Flag'S Dispensation. System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Component: 09298 - Other (Accident Prevention) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Condition Of The Ship And Its Equipment Shall Be Maintained To Conform With The Provisions Of The Present Regulations To Ensure That The Ship In All Respects Will Remain Fit To Proceed To Sea Without Danger To The Ship Or Persons On Board. Ships Pars/Supplies/Gear Is Adrift Throughout The Cargo Compressor Room Causing An Unsafe Risk To Critical Equipment In A Hazardous Zone 1 Space. 74SOLAS(20) I/11a 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/5/2024 12:00:00 AM Resolution Description: Vessel Provided Satisfactory Class Tech Report. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07106 - Fire Detection And Alarm System Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Following Fire Protection Systems Shall Be Kept In Good Order So As To Ensure Their Required Performance If A Fired Occurs: Fire Detection And Fire Alarm Systems. Engine Room Alarm Columns Did Not Display Or Sound At Various E/R Alarm Columns. 74SOLAS(09) II-2/14.2.1.1.2 17ac Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/13/2024 12:00:00 AM Resolution Description: Class Has Given The Vessel 30 Days To Rectify IAW With Flag'S Dispensatiion. |