BoatDB
Vessel

GINGA MAYA

IMO 9339351
TankerBuilt 2005Active
11,690
Gross tonnageA measure of the vessel's total internal volume (not its weight).
19,728
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2005
Year built

Live position & voyage

LIVE
Loading position…

Shipments over time

bills of lading per month

Particulars

IMO
9339351
MMSI
563326400
Call sign
S6US5
Flag
SG
Type
Oil Or Chemical Tanker
Length (LOA)
144.09 m
Beam
24.2 m
Home port
HELLERUP

Ownership

Beneficial owner
Operator
MOL Chemical Tankers Europe· Denmark
Technical manager
Commercial manager
MOL Chemical Tankers Europe
Class society
BV
Design DWT
19,728 t
Flag
Denmark (DIS)
Built
2005

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Sold
    $19M
  4. Built

Engine

main engine & propulsion
Engine builder
Makita Corp.
Designer
MAN B&W
Designation
6S42MC-MKVI
Power (MCO)
8,362 BhP
RPM
136
Propulsion
MO
Trading category
Live

Surveys & certificates

dry dock & statutory certificates
Last dry dock
10 Oct 2023
Special survey
23 Aug 2025
IOPP issued
05 Dec 2022
IOPP expires
23 Aug 2025

Top importers served

importers this vessel carried for

Shipments carried

recent bills of lading

Inspections

recent port state control
DatePortDetainedDeficiencies
23 Mar 2026CallaoNo0
01 Mar 2026MobileNo0
11 Dec 2025AntwerpenNo1101139, Maritime Labour Certificate, Certificate & Documentation - Ship Certificates, 1250, See Comment,14807, Performance Standard Not Met, Pollution Prevention - Ballast Water, 1000, Missing,14802, Ballast Water Record Book, Pollution Prevention - Ballast Water, 1002, Entries Missing,11131, On Board Training And Instructions, Life Saving Appliances, 1011, Not As Required,01139, Maritime Labour Certificate, Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled,14614, Sulphur Oxides, Pollution Prevention - Marpol Annex VI, 1011, Not As Required,14699, Other MARPOL Annex VI, Pollution Prevention - Marpol Annex VI, 1238, Other,18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe,13104, Bilge Pumping Arrangements, Propulsion And Auxiliary Machinery, 1082, Inoperative,06106, Cargo Transfer - Tankers, Cargo Operations Including Equipment, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required
14 Aug 2025New OrleansNo0
08 Jun 2025Gresik, JavaNo0
24 May 2024Port-AlfredYes2418316, Water, Pipes, Tanks, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1011, Not As Required,03104, Cargo & Other Hatchways, Water/Weathertight Conditions, 1026, Damaged,18312, Galley, Handlingroom (Maintenance), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,11124, Embarkation Arrangement Survival Craft, Life Saving Appliances, 1000, Missing,18417, Anchoring Devices, Labour Conditions - Health Protection, Medical Care, Social Security, 1026, Damaged,04116, Means Of Communication Between Safety Centre And Other Control Stations, Emergency Systems, 1086, Not Properly Maintained,02101, Closing Devices/Watertight Doors, Structural Conditions, 1011, Not As Required,04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required,10110, Signalling Lamp, Safety Of Navigation, 1082, Inoperative,18305, Hospital Accomodation (Sickbay), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,08109, Boiler Alarm, Alarms, 1100, Malfunctioning,10109, Lights, Shapes, Sound-Signals, Safety Of Navigation, 1082, Inoperative,07115, Fire-Dampers, Fire Safety, 1011, Not As Required,14501, Garbage Shipboard Handling, Pollution Prevention - Marpol Annex V, 1011, Not As Required,03109, Machinery Space Openings, Water/Weathertight Conditions, 1011, Not As Required,02107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required,07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required,18428, On Board Programme For The Prevention Of Occupational Injuries And Deaseases, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,01323, Fire Safety Operational Booklet, Certificate & Documentation - Documents, 1031, Incomplete,02101, Closing Devices/Watertight Doors, Structural Conditions, 1118, Not Properly Secured,02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required
24 May 2024QuebéC CityNo0
10 May 2024HoustonNo0
11 Jan 2024CallaoNo0
10 Jan 2023CallaoNo0
18 Nov 2021Saint-JohnNo518314, Provisions Quantity, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1036, Insufficient, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 10103, Radar, Safety Of Navigation, 1082, Inoperative, 18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1082, Inoperative, 01214, Endorsement By Flagstate, Certificate & Documentation - Crew Certificates, 1000, Missing,, 0

Sale & demolition history

reported transactions & recycling
DateEventPriceReported sale price in US$ millions.Buyer
28 Aug 2012 Reported Sold$19M