| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 13 Mar 2025 | Hamburg | No | 407115, Fire-Dampers, Fire Safety, 1011, Not As Required,08107, Machinery Controls Alarm, Alarms, 1075, Inadequate,02105, Steering Gear, Structural Conditions, 1011, Not As Required,18420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required |
| 01 Oct 2024 | Szczecin |
| No |
| 5Radio Communications 05111 - Satellite EPIRB 406MHz/1.6GHz Not As Required Yes Fire Safety 07117 - Jacketed High Pressure Lines And Oil Leakage Alarm Not As Required Yes Life Saving Appliances 11108 - Inflatable Liferafts Expired Yes Emergency Systems 04114 - Emergency Source Of Power - Emergency Generator Not As Required Yes ISM 15150 - ISM Not As Required |
| 20 Jun 2024 | Jossingfjord | No | 4Life Saving Appliances - Rescue Boats Not Ready For Use ; ISM - ISM Not As Required ; Fire Safety - Fire Pumps And Its Pipes Not As Required ; Safety Of Navigation - Pilot Ladders And Hoist/Pilot Transfer Arrangements Unsafe |
| 15 Aug 2023 | Horsens | No | 2Labour Conditions - Accommodation, Recreational Facilities, Food And Catering; 18324 - Cold Room, Cold Room Cleanliness, Cold Room Temperature; Missing; Certificate & Documentation - Documents; 01309 - Fire Control Plan - All; Not Updated |
| 03 May 2023 | Lisboa | No | 206107, Cargo Operation, Cargo Operations Including Equipment, 1075, Inadequate, 1515ISM, ISM, 1011, Not As Required, |
| 16 Jan 2023 | Mosjoen | No | 0 |
| 25 Feb 2022 | Bilbao | No | 0 |
| 19 Feb 2021 | Almeria | No | 204103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1082, Inoperative, 10105, Magnetic Compass, Safety Of Navigation, 1011, Not As Required, , 0 |