Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 27 Mar 2026 | Tripoli | No | 2Structural Conditions 02105 - Steering Gear Not As Required Fire Safety 07101 - Fire Prevention Structural Integrity Not As Required Total 0 0 0 0 |
| 26 Nov 2025 | Chornomorsk | No | 0 |
| Date | Type | Details |
|---|---|---|
| 12 Nov 2022 | Fire | Vessel had fire on board during discharge operation at Darica, Turkey. Fire was extinguished same day. Investigation on. Vessel sailed from Darica on 13 November for Ravenna. |
| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 08 Jun 2009 |
| 30 Apr 2025 |
| Belawan, Sumatra |
| No |
| 31 03102 WATER/WEATHERTIGHT CONDITIONS (Freeboard Marks) No 2 03103 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) No 3 04103 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) No |
| 26 Dec 2024 | Gresik | No | 210199 SAFETY OF NAVIGATION (Other (Navigation)) No 2 09198 LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Other (Crew And Accommodation)) No |
| 27 Aug 2024 | Port Sudan | No | 0 |
| 13 Oct 2023 | Novorossiisk | No | 6WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Electrical) ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Preventative Information) ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Lighting (Working Spaces)) ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Winches & Capstans) ; WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) |
| 12 Sep 2023 | Venezia | No | 518425, Access / Structural Features (Ship), Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1086, Not Properly Maintained, 02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required, 07117, Jacketed High Pressure Lines And Oil Leakage Alarm, Fire Safety, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required |
| 10 Jul 2023 | Samsun | No | 6SAFETY OF NAVIGATION (Voyage Data Recorder (VDR)/Simplified Voyage Data Recorder(S-VDR)) ; CERTIFICATE AND DOCUMENTATION - CREW CERTIFICATES (Endorsement By Flagstate) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Lighting (Working Spaces)) ; LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Electrical Devices) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Protection Machinery) ; PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) |
| 27 Mar 2023 | Venezia | No | 211135, Maintenance Of Life Saving Appliances, Life Saving Appliances, 1011, Not As Required, 07124, Maintenance Of Fire Protection Systems, Fire Safety, 1011, Not As Required |
| 03 Oct 2022 | Ravenna | No | 310127, Voyage Or Passage Plan, Safety Of Navigation, 1011, Not As Required, 07110, Fire Fighting Equipment And Appliances, Fire Safety, 1086, Not Properly Maintained, 04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1086, Not Properly |
| 20 Sep 2022 | Ambarli | No | 0 |
| 20 Apr 2022 | Venezia | No | 402103, Stability/Strength/Loading Information And Instruments, Structural Conditions, 1031, Incomplete, 10105, Magnetic Compass, Safety Of Navigation, 1011, Not As Required, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As R |
| 19 Oct 2021 | Ravenna | No | 807105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 02122, Openings To Cargo Area, Doors, ... Scuttles, Structural Conditions, 1026, Damaged, 18424, Steam Pipes, Pressure Pipes, Wires (Insulation), Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18313, Cleanliness, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1016, Dirty, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 18314, Provisions Quantity, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1036, Insufficient, 07110, Fire Fighting Equipment And Appliances, Fire Safety, 1086, Not Properly Maintained, 01330, Procedure For Complaint Under MLC,2006, Certificate & Documentation - Documents, 1011, Not As Required, |
| 15 Apr 2021 | Ravenna | No | 401123, Continuous Synopsis Record, Certificate & Documentation - Ship Certificates, 1002, Entries Missing, Other, Other, Other, Other, Other, Other, Other, Other, Other, Other, 18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Fa |
| $14.1M |
| — |