Vessel
HF HUNTER
IMO 9269506
CargoBuilt 2003Active
2,085
Gross tonnageA measure of the vessel's total internal volume (not its weight).
2,382
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
—
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2003
Year built
Live position & voyage
LIVELoading position…
Particulars
- IMO
- 9269506
- MMSI
- 304092000
- Call sign
- V2RE5
- Flag
- AG
- Type
- Fire Fighting Vessel
- Length (LOA)
- 68.95 m
- Beam
- 15.5 m
- Home port
- —
Ownership
- Beneficial owner
- —
- Operator
- —
- Technical manager
- —
- Commercial manager
- —
- Class society
- BV
- Design DWT
- 2,382 t
- Flag
- Marshall Islands
- Built
- 2003
Timeline
key events over the vessel's life- Special survey
- Built
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- —
- Special survey
- 08 Aug 2023
- IOPP issued
- —
- IOPP expires
- —
Shipments carried
recent bills of ladingNo shipment records.
Inspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 14 May 2025 | Houma | No | 5System: 99 - Other Sub-System: N/A - No Subsystem Component: 99101 - Other (Safety In General) Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: A Vessel Greater Than Or Equal To 300 Gross Tons Or Has The Capacity To Hold Or Discharge 8 Cubic Meters (2113 Gallons) Of Ballast Water Shall Submit A Notice Of Intent. PSCO Observed That The Vessel Did Not Submit A Notice Of Intent. VGP Part 1.5.1.1; Part 10. Appendix E – Notice Of Intent (NOI) Due Date: N/A Deficiency Resolved? Yes Resolved Date: 6/16/2025 12:00:00 AM Resolution Description: Verified Vessel Had VGP And Notice Of Intent On Board. System: 01 - Certificates & Documentation Sub-System: 011 - Ships Certificates Component: 01117 - International Oil Pollution Prevention (IOPP) Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: An International Oil Pollution Prevention Certificate Shall Be Issued After An Initial Or Renewal Survey In Accordance With The Provisions Of Regulation 6 Of This Annex. PSCO Observed Approval Standards For The Separating/Filtering Equipment And The Oil Content Meter Was Approved In Accordance With Resolution MEPC.60(33), However The Installed Equipment Is MPEC.107(49). MARPOL I/7.1 16c Due Date: N/A Deficiency Resolved? Yes Resolved Date: 6/16/2025 12:00:00 AM Resolution Description: Verified Class Issued Updated IOPP Form A Reflecting Correct OWS Equipment On Board. System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Component: 10199 - Other (Navigation) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Ships Shall Be Fitted With A System To Automatically Transmit The Information Specified In Paragraph 5 As Follows: Ships Constructed Before 31 December 2008 And Certified For Operation In Sea Areas A1, A2, And A3. LRIT Failed On 15MAY2025. SOLAS (20) V/19-1.4.1.2.2 17c Due Date: N/A Deficiency Resolved? Yes Resolved Date: 6/16/2025 12:00:00 AM Resolution Description: Recieved Copy Of LRIT Performance Test Completed. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07124 - Maintenance Of Fire Protection Systems Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Following Fire Protection Systems Shall Be Kept In Good Order So As To Ensure Their Required Performance If A Fire Occurs: Fire Detection And Fire Alarm Systems. PSCO Observed Fault On Fire Panel Due To Internal Battery Failure. SOLAS (09) II-2/14.2.1.1.2 17c Due Date: N/A Deficiency Resolved? Yes Resolved Date: 6/16/2025 12:00:00 AM Resolution Description: PSCO Verified Installation Of New Batteries. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Following Fire Protection Systems Shall Be Kept In Good Order So As To Ensure Their Required Performance If A Fire Occurs: Structural Fire Protection, Including Fire-Resisting Divisions, And Protection Of Openings And Penetrations In These Divisions. PSCO Observed Broken A-60 Door In Galley, Only Allowing Opening Of The Door From Outside The Space. SOLAS (09) II-2/14.2.1.1.1 17c Due Date: N/A Deficiency Resolved? Yes Resolved Date: 6/16/2025 12:00:00 AM Resolution Description: PSCO Verified Operation Of The Fire Door. |