| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 02 Jan 2026 | Corpus Christi | No | 4System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07123 - Operation Of Fire Protection Systems Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: B - To The Satisfaction Of The Administration Description Of Deficiency: All Nozzles And Other Fittings In The Water-Spray Systems Should Be Resistant To Corrosionby Sea-Water. 05 Nozzles Were Found To Be Corroded Shut And Did Not Disperse Any Water When The System Was Energized. SOLAS (20)74 VII/13.1; IGC 11.3.5 Due Date: 1/2/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/3/2026 12:00:00 AM Resolution Description: Received Flag And Class Documentation. All Sat. System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Component: 09209 - Electrical Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: B - To The Satisfaction Of The Administration Description Of Deficiency: Electrical Installations Should Be Such As To Minimize The Risk Of Fire And Explosion From Flammable Products. The Emergency Light Installed Near The Forward Liferaft Was Not Certified For Gas-Dangerous Spaces, Imposing An Unnecessary Risk Of Fire Or Explosion. SOLAS (20)74 VII/13.1; IGC (93) 10.1.2 Due Date: 1/2/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/3/2026 12:00:00 AM Resolution Description: Received Flag And Class Documentation. All Sat. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06107 - Cargo Operation Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: B - To The Satisfaction Of The Administration Description Of Deficiency: For Cargo Tanks With A MARVS (Maximum Allowable Relief Valve Setting) Exceeding 0.7 Bar Gauge, All Liquid And Vapour Connections, Except For Safety Relief Valves And Liquid Level Gauging Devices, Should Be Equipped With A Manually Operated Stop Valve And A Remotely Controlled Emergency Shutdown Valve. The Liquid Filling Valve For The Single Type C Deck Tank Was Found Inoperable. This Cargo Tank Cannot Be Loaded Until All Liquid And Vapor Connections To The Tank Are Found In Satisfactory Condition To The Administration. SOLAS (20)74 VII13.1; IGC (93) 5.6.1.2 Due Date: 1/2/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/3/2026 12:00:00 AM Resolution Description: Received Flag And Class Documentation. All Sat. System: 09 - Working And Living Conditions Sub-System: 092 - Working Conditions Component: 09209 - Electrical Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: B - To The Satisfaction Of The Administration Description Of Deficiency: Where Electrical Equipment Is Installed In Gas Dangerous Spaces, It Should Be To The Satisfaction Of The Administration And Approved By The Relevant Authourities. Multiple Lights On The Open Cargo Deck Contained Excessivee Standing Liquidand Dust, Indicating Noncompliance With Proper Installation Standards. Rectify Prior To Cargo Operation. SOLAS (20)74 VII/13.1; IGC (93) 10.1.5 Due Date: 1/2/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 1/3/2026 12:00:00 AM Resolution Description: Received Flag And Class Documentation. All Sat. |
| 26 Dec 2024 | Corpus Christi | No | 4System: 15 - Safety Management Systems (ISM) Sub-System: N/A - No Subsystem Component: 15109 - Maintenance Of The Ship And Equipment Cause: Improper/Lack Of Maintenance Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: A - To The Satisfaction Of |
| 18 Dec 2023 | Corpus Christi | No | 5System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: Decontamination Shower/Eyewash - The Showers And Eyewash Should Be Operable In All Ambient Conditions. The STBD Eyewash Was Clogged, And The Port Station Did Not Have Water Available. 74 SOLAS (20) VII/13.1 - ICG(93) 14.4.3 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/27/2023 12:00:00 AM Resolution Description: Crew Cleaned The Lines On The STBD Eyewash, Replaced The Valve On The PORT Side, Tested Sat By Class. System: 02 - Structural Conditions Sub-System: N/A - No Subsystem Cause: Damaged By Earlier Event Description Of Deficiency: Electrical Installations Should Be Such As To Minimize The Risk Of Fire And Explosion From Flammable Products. Four Explosion Proof Lights Were Found With Cracked Lenses In The Cargo Compressor And One Above The Starboard Compressor. 74 SOLAS (20) VII/13.1 - IGC (93) 10.1.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/27/2023 12:00:00 AM Resolution Description: Class Verified That The Lights Were Removed And Electrically Isolated, Issued A Condition Of Class For 90 Days To Allow The Vessel To Procure Replacements In Kind. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Placed In Improper Service Description Of Deficiency: Gas Detection - When Such Equipment Is Located In A Gas - Safe Space The Following Conditions Should Be Met: Exhaust Gas From The Detector Should Be Discharged To The Atmosphere In A Safe Location. The Gas-Tight Steel Cabinet That Houses The Fixed Gas-Sampling Instruments Has Over 30 Holes Drilled Into The Door. 74 SOLAS (20) VII/13.1-IGC(93)13.6.5.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/27/2023 12:00:00 AM Resolution Description: Crew Used Epoxy Putty To Seal The Drilled Holes In The Cabinet. System: 09 - Working And Living Conditions Sub-System: 091 - Living Conditions Cause: Improper/Lack Of Maintenance Description Of Deficiency: Hot Fresh Water Or Means Of Heating Water Shall Be Available In All Communal Wash Places. Hot Water Was Tested In Multiple Areas Around The Ship And Never Warmed Higher Than Room Temperature. 46 USC 70002 - ILO-147 Pg. 37 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/27/2023 12:00:00 AM Resolution Description: Heating Coil Was Replaced By The Engineering Crew. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: The Fire Resistance Of Doors Shall, As Far As Practicable, Be Equivalent To That Of The Division In Which They Are Fitted. Multiple Fire Doors In The Accommodation Space Were Not Marked With The Fire Rating, And Others Showed Signs Of On Board Repair. Class Should Review All Fire Doors To Ensure They Are Equivalent To The Division They Are Fitted. 74 SOLAS (97)II-2/47.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/27/2023 12:00:00 AM Resolution Description: Class Verified All Doors Met The Standard Outlined In The FCP And Doors Were Labeled Appropriately. |