Vessel
HURON
IMO 9457878
TankerBuilt 2010Active
12,890
Gross tonnageA measure of the vessel's total internal volume (not its weight).
21,224
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
—
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2010
Year built
Live position & voyage
LIVELoading position…
Shipments over time
bills of lading per monthParticulars
- IMO
- 9457878
- MMSI
- 538011029
- Call sign
- V7A6477
- Flag
- MH
- Type
- Oil Or Chemical Tanker
- Length (LOA)
- 156.69 m
- Beam
- 22.9 m
- Home port
- VALLETTA
Ownership
- Beneficial owner
- —
- Operator
- —
- Technical manager
- —
- Commercial manager
- —
- Class society
- NK
- Design DWT
- 21,224 t
- Flag
- Malta
- Built
- 2010
Timeline
key events over the vessel's life- Special survey
- Dry dock
- Sold$15M
- Built
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- 12 Jul 2028
- Special survey
- 12 Jul 2030
- IOPP issued
- 13 Jul 2025
- IOPP expires
- 12 Jul 2030
Top importers served
importers this vessel carried forShipments carried
recent bills of ladingInspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 27 May 2026 | Trois-Rivieres (Three Rivers) | No | 1403110, Manholes/Flush Scuttles, Water/Weathertight Conditions, 1026, Damaged,14602, Record Book Of Engine Parameters, Pollution Prevention - Marpol Annex VI, 1002, Entries Missing,02101, Closing Devices/Watertight Doors, Structural Conditions, 1026, Damaged,11101, Lifeboats, Life Saving Appliances, 1086, Not Properly Maintained,14402, Sewage Treatment Plant, Pollution Prevention - Marpol Annex IV, 1011, Not As Required,10109, Lights, Shapes, Sound-Signals, Safety Of Navigation, 1082, Inoperative,07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required,18305, Hospital Accomodation (Sickbay), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,02117, Decks - Corrosion, Structural Conditions, 1029, Corroded,15150, ISM, ISM, 1011, Not As Required,11116, Distress Flares, Life Saving Appliances, 1000, Missing,13103, Gauges,Thermometers, Etc, Propulsion And Auxiliary Machinery, 1082, Inoperative,14101, Control Of Discharge, Pollution Prevention - Marpol Annex I, 1011, Not As Required,14101, Control Of Discharge, Pollution Prevention - Marpol Annex I, 1011, Not As Required |
| 11 Apr 2026 | La Rochelle | No | 607108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1082, Inoperative,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required,07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1082, Inoperative,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1082, Inoperative,18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe |
| 08 Apr 2025 | Valletta | No | 5Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Life Saving Appliances 11124 - Embarkation Arrangement Survival Craft Not Properly Maintained Safety Of Navigation 10116 - Nautical Publications Missing Certificate & Documentation - Documents 01324 - Material Safety Data Sheets(MSDS) Missing Fire Safety 07111 - Personal Equipment For Fire Safety Not As Required Total 0 0 0 0 |
| 19 Apr 2023 | Novorossiisk | No | 91 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Safe Means Of Access) Rectify Deficiency Before Departure Deficiency Rectified 2 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) Rectify Deficiency Before Departure Deficiency Rectified 3 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Safe Means Of Access Deck - Hold/Tank, Etc.) Rectify Deficiency Before Departure Deficiency Rectified 4 LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Pipes, Wires (Insulation)) Rectify Deficiency Before Departure Deficiency Rectified 5 SAFETY OF NAVIGATION (Lights, Shapes, Sound-Signals) Rectify Deficiency Before Departure Deficiency Rectified 6 LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Pipes, Wires (Insulation)) Rectify Deficiency Before Departure Deficiency Rectified 7 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Warning Notices) Rectify Deficiency Before Departure Deficiency Rectified 8 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) Rectify Deficiency Before Departure Deficiency Rectified 9 POLLUTION PREVENTION - MARPOL ANNEX I (SBT, CBT, COW) Rectify Deficiency Before Departure Deficiency Rectified |
| 21 Mar 2023 | Genova | No | 803102, Freeboard Marks, Water/Weathertight Conditions, 1046, Not Properly Marked, 01101, Cargo Ship Safety Equipment (Including Exemption), Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled, 18410, Gas Instruments, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 01209, Manning Specified By The Minimum Safe Manning Doc, Certificate & Documentation - Crew Certificates, 1002, Entries Missing, 07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative, 07117, Jacketed High Pressure Lines And Oil Leakage Alarm, Fire Safety, 1082, Inoperative, 15150, ISM, ISM, 1011, Not As Required |
| 07 Nov 2022 | San Vicente | No | 2CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Minimum Safe Manning Document) ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Medical Equipment, Medical Chest, Medical Guide) |
| 14 Apr 2022 | Klaipeda | No | 218420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, |
| 14 Apr 2021 | Augusta | No | 404109, Fire Drills, Emergency Systems, 1207, Lack Of Knowledge, 07115, Fire-Dampers, Fire Safety, 1011, Not As Required, 07102, Inert Gas System, Fire Safety, 1011, Not As Required, 01310, Signs, Indications, Certificate & Documentation - Documents, 1011, |
Sale & demolition history
reported transactions & recycling| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 25 Sep 2024 | Reported Sold | $15M | Unknown |