Loading…
| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 08 Sep 2024 | Ocp North America Inc | mono-ammonium phosphate (map) | NMCV202409031 |
| 07 Sep 2021 | Tata International Metals Americas Ltd | lot4 prime quality dry hot rolled steel sheets in coils |
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 08 Apr 2026 | Texas City | No | 5System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Component: 10113 - Automatic Identification System (AIS) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: All Ships Of 300 Gross Tonnage And Upwards Shall Be Fitted With An Automatic Identification System (AIS). PSCO Observed AIS Is Inoperable. 74SOLAS(20)V/19.2.4 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Vessel Submitted Technical Report And Test Confirming Repair Of AIS System. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07199 - Other (Fire Safety) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Cylinders Must Always Be Secured And, When Not In Use, They Must Be Stowed In A Rack In An Upright Position. PSCO Observed 04 Oxygen Cylinders And 04 Acetylene Cylinders Not Stored In A Rack. 46CFR147.60(B)(I) Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Crew Installed Rack For Additional Cylinders System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Doors Fitted In Boundary Bulkheads Of Machinery Spaces Of Category A Shall Be Reasonably Gas Tight And Self Closing. PSCO Observed 04 Class A Fire Doors That Did Not Self Close. 74SOLAS(24) II-2/9.4.2.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/8/2026 12:00:00 AM Resolution Description: Crew Members Addressed All Doors That Were Not Closing By Making Proper Adjustments. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Master Must Ensure The Maintenance Of Written Or Digital Records. PSCO Observed Events Listed On Monitoring Panel Does Not Match Ballast Water Record Book. Crew Also Failed To Properly Log Non-Operational No. 1 BWTS. 33CFR151.2070 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Crew Updated Log With Proper Entries. System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Component: 10199 - Other (Navigation) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: With The Exceptions Noted In Paragraph B Of This Section Each NOA Must Contain All Of The Information Items Specified In Table 160.206. PSCO Observed Vessel With Inoperable AIS Not Reported To COTP Or Listed On NOA. 33CFR160.206(A) Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Vessel Updated ENOA Listing With Inop Equipment. |
| Date | Type | Details |
|---|---|---|
| 10 Mar 2020 | Collision | Sea Poseidon while navigating in Sao Luiz Anchorage area, Brazil came in contact with vessel on 10 Mar 2020. Both vessels sustained minor damages. No oill spill or injuries reported. |
| 24 Aug 2021 | Tata International Metals Americas Ltd | lot1 prime quality dry hot rolled steel sheets in coils | LNAS2021355 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | lot2 prime quality dry hot rolled steel sheets in coils | LNAS2021356 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | lot3 prime quality dry hot rolled steel sheets in coils | LNAS2021357 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | lot5 prime quality dry hot rolled steel sheets in coils | LNAS2021358 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | prime hot dipped galvanized steel coils | LNAS2021359 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | prime hot dipped galvanized steel coils | LNAS2021360 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | prime hot dipped galvanized steel coils | LNAS2021361 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | prime hot dipped galvanized steel coils | LNAS2021362 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | prime cold rolled steel coils | LNAS2021363 |
| 24 Aug 2021 | Tata International Metals Americas Ltd | prime hot dipped galvanized steel coils | LNAS2021364 |
| 12 Nov 2025 | El Iskandariya (Alexandria) | No | 0 |
| 19 Sep 2025 | Szczecin | No | 7Propulsion And Auxiliary Machinery 13102 - Auxiliary Engine Not As Required Yes Fire Safety 07112 - Emergency Escape Breathing Device And Disposition Not As Required Pollution Prevention - Ballast Water 14801 - Ballast Water Management Plan Not Approved Safety Of Navigation 10112 - Electronic Charts (ECDIS) Not As Required Safety Of Navigation 10114 - Voyage Data Recorder (VDR) / Simplified Voyage Data Recorder (S-VDR) Not As Required Yes Safety Of Navigation 10199 - Other (Navigation) Other Yes ISM 15150 - ISM Not As Required |
| 31 Mar 2025 | Salaverry | No | 0 |
| 10 May 2024 | Callao | No | 2LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Access/Structure) No 2 01310 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Signs, Indications) |
| 08 Apr 2024 | Texas City | No | 5System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Component: 10113 - Automatic Identification System (AIS) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: All Ships Of 300 Gross Tonnage And Upwards Shall Be Fitted With An Automatic Identification System (AIS). PSCO Observed AIS Is Inoperable. 74SOLAS(20)V/19.2.4 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Vessel Submitted Technical Report And Test Confirming Repair Of AIS System. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07199 - Other (Fire Safety) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Cylinders Must Always Be Secured And, When Not In Use, They Must Be Stowed In A Rack In An Upright Position. PSCO Observed 04 Oxygen Cylinders And 04 Acetylene Cylinders Not Stored In A Rack. 46CFR147.60(B)(I) Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Crew Installed Rack For Additional Cylinders System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07105 - Fire Doors/Openings In Fire-Resisting Divisions Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Doors Fitted In Boundary Bulkheads Of Machinery Spaces Of Category A Shall Be Reasonably Gas Tight And Self Closing. PSCO Observed 04 Class A Fire Doors That Did Not Self Close. 74SOLAS(24) II-2/9.4.2.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/8/2026 12:00:00 AM Resolution Description: Crew Members Addressed All Doors That Were Not Closing By Making Proper Adjustments. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Master Must Ensure The Maintenance Of Written Or Digital Records. PSCO Observed Events Listed On Monitoring Panel Does Not Match Ballast Water Record Book. Crew Also Failed To Properly Log Non-Operational No. 1 BWTS. 33CFR151.2070 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Crew Updated Log With Proper Entries. System: 10 - Safety Of Navigation Sub-System: N/A - No Subsystem Component: 10199 - Other (Navigation) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: With The Exceptions Noted In Paragraph B Of This Section Each NOA Must Contain All Of The Information Items Specified In Table 160.206. PSCO Observed Vessel With Inoperable AIS Not Reported To COTP Or Listed On NOA. 33CFR160.206(A) Due Date: N/A Deficiency Resolved? Yes Resolved Date: 4/9/2026 12:00:00 AM Resolution Description: Vessel Updated ENOA Listing With Inop Equipment. |
| 12 Feb 2024 | Samsun | No | 0 |
| 18 Jan 2024 | Boston, Massachusetts | No | 0 |
| 09 Aug 2023 | Aliaga | No | 1Certificate & Documentation - Ship Certificates 01117 - International Oil Pollution Prevention (IOPP) Entries Missing Total 0 0 0 0 |
| 19 Jun 2023 | Nantes-Saint Nazaire (Gpm) | No | 0 |
| 11 Apr 2022 | Donghae | No | 21 03102 WATER/WEATHERTIGHT CONDITIONS (Freeboard Marks) No 2 06105 CARGO OPERATIONS INCLUDING EQUIPMENT (Atmosphere Testing Instruments) No |
| 28 Mar 2022 | Donghae | No | 41 04103 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) No 2 11117 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) No 3 03102 WATER/WEATHERTIGHT CONDITIONS (Freeboard Marks) No 4 06105 CARGO OPERATIONS INCLUDING EQUIPMENT |
| 19 Apr 2021 | Kotka | No | 0 |