| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 28 Apr 2024 | Christiansted | No | 5System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07106 - Fire Detection And Alarm System Cause: Action: 16 - Rectify Deficiencies W/In 14 Days Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: ANy Fixed Fire Detection Shall Be Capabale Of Immediate Operation At All Times. The Smoke Detector Above The Generator Is Inoperable. 74SOLAS2001 II-2/13.1.1 Due Date: 5/12/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 5/2/2024 12:00:00 AM Resolution Description: Received Class Report Stating Smoke Detector Was Replaced And Satisfactorily Tested. System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Component: 11101 - Lifeboats Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Before The Ship Leaves Port And At All Times During The Voyage, All Lifesaving Appliances Shall Be In Working Order And Ready For Immediate Use. The Port Lifeboat Is Not Able To Turn To Starboard. 74SOLAS2020 III/20.1 Due Date: 4/28/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/28/2024 12:00:00 AM Resolution Description: Ships Crew Repaired Steering Prior To PSCO Departure. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06105 - Atmosphere Testing Instruments Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Tankers Shall Be Equipped With At Least One Portable Instrument For Measuring Oxygen And One For Measuring Flammable Vapor Concentrations, Together With A Sufficient Set Of Spares. Suitable Means Shall Be Provided For The Calibration Of Such Instruments. One Of The Portable Gas Detectors Is Not Operable And The Other Is Not Able To Be Calibrated. 74SOLAS2001 II-2/59.5 Due Date: 4/28/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/29/2024 12:00:00 AM Resolution Description: Vessel Received Two New Portable Gas Detectors And Training On Use And Calibration. PSCO Verified Proper Operation And Crew Competency With The New Gas Detectors Via Satisfactory Calibration And Function Checks Of Both New Detectors. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06103 - Other Cargo/Timber/Deck/Construction Cause: Action: 40 - Rectify Deficiencies Prior To Next US Port After Sailing Foreign Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Last 1 Meter Of Vapor Piping Must Be Painted In The Sequence Red/Yellow/Red. The Starboard Manifolds Vapor Piping Is Not Painted. 46CFR39.2001(H) Due Date: 4/28/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/29/2024 12:00:00 AM Resolution Description: Vessels Crew Painted The Vapor Mainold In The Sequence Red/Yellow/Red. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06106 - Cargo Transfer - Tankers Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Venting System Shall Be Provided With Devices To Prevent The Passage Of Flames Into The Cargo Tanks. 25% Of The Vessels Flame Screens Are Covered In Oil And Connot Operate As Intended. 74SOLAS2001 II-2/59.1.5 Due Date: 4/28/2024 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 4/29/2024 12:00:00 AM Resolution Description: Vessels Crew Cleaned Or Replaced The Dirty Flame Screens. |
| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 09 Jul 2019 |
| 28 Sep 2023 | Naples | No | 5Enhanced Survey Programme (ESP) Documentation Missing ; Protection Machines/Parts Not As Required ; Fire-Dampers Not As Required ; Fire Fighting Equipment And Appliances Not As Required ; Messroom And Recreational Facilities Not As Required |
| 15 Feb 2022 | Cilacap | No | 0 |
| $9M |
| Benetech Shipping SA |