Loading…
| Arrival | Importer | Product | B/L |
|---|---|---|---|
| 31 Oct 2022 | Eastern Salt Company Inc | salt in bulk deicing grade | WBCP00087944A |
| 27 Oct 2022 | Eastern Salt Company Inc | salt in bulk deicing grade | WBCP00087944 |
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 17 Feb 2026 | Kobe | Yes | 31 10109 SAFETY OF NAVIGATION (Lights, Shapes, Sound-Signals) No 2 07109 FIRE SAFETY (Fixed Fire Extinguishing Installation) Yes 3 14601 POLLUTION PREVENTION - MARPOL ANNEX VI (Technical Files And If Applicable, Monitoring Manual) Yes |
| 15 Sep 2025 | Vung Ang |
| No |
| 0 |
| 02 Jul 2025 | Portland | No | 3System: 15 - Safety Management Systems (ISM) Sub-System: N/A - No Subsystem Component: 15106 - Shipboard Operations Cause: Improper Installation Action: 17 - Rectify Deficiencies Prior To Departure Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Cylinders Must Always Be Secured And When Not In Use, They Must Be Stowed In A Rack In An Upright Position, With The Valve Protection Cap In Place. PSCO Observed 03 Oxygen Cylinders, 04 Acetylene Cylinders Stored Loose Inside The Acetylene Locker, With An Additional 05 Acetylene Cylinders Mounted Properly Inside. A Loose Heavy Cylinder Cart Was Stored Between The Loose Bottles, Also Unsecured. Additionally 02 Loose Oxygen Bottles Inside The Oxygen Locker With The Properly Secured Oxygen Bottles. Rope Was Loosely Aligned Over These Unsecured Bottles. All Unsecured Bottles Were Sitting Directly On The Deck. 46 CFR 147.60(B)(I) Due Date: N/A Deficiency Resolved? Yes Resolved Date: 7/3/2025 12:00:00 AM Resolution Description: VESSEL PROVIDED CLASS SURVEY CONFIRMING RECTIFICATION OF DEFICIENCY. System: 14 - Pollution Prevention Sub-System: 147 - Anti-Fouling Component: 14799 - Other (AFS) Cause: Improper/Lack Of Maintenance Action: 40 - Rectify Deficiencies Prior To Next US Port After Sailing Foreign Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Remove Fouling Organisms From The Vessel'S Hull, Piping, And Tanks On A Regular Basis And Dispose Of Any Removed Substances In Accordance With Local, State And Federal Regulations. PSCO Observed Excessive Hull Growth Of Microorganisms On The Stern Of The Hull. 33 CFR 151.2050 (F) Due Date: N/A Deficiency Resolved? No Resolved Date: N/A Resolution Description: N/A System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07199 - Other (Fire Safety) Cause: Improper/Lack Of Maintenance Action: 40 - Rectify Deficiencies Prior To Next US Port After Sailing Foreign Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: The Purpose Of This Regulation Is To Prevent The Ignition Of Combustible Materials Or Flammable Liquids. For This Purpose, The Following Functional Requirements Shall Be Met:... The Ignitability Of Combustible Materials Shall Be Restricted. PSCO Observed Observed Oily Rags And Wood In Engine Spaces And Oily Rags In BSN Store, Which Were Not Stored Properly And Are Combustible Materials. Additionally, A Wooden Crate Was Tied To Piping On The Boiler And Additionally Wooden Crates Stored Surrounding The Boiler. 74 SOLAS (09) II-2/4.1.3 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 7/3/2025 12:00:00 AM Resolution Description: VESSEL PROVIDED CLASS SURVEY CONFIRMING RECTIFICATION OF DEFICIENCY. |
| 12 Jun 2025 | Qingdao | No | 41 11104 LIFE SAVING APPLIANCES (Rescue Boats) (11.06.2025) No 2 07110 FIRE SAFETY (Fire Fighting Equipment And Appliances) (11.06.2025) No 3 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) (11.06.2025) No 4 07105 FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) (11.06.2025) |
| 11 Jun 2025 | Qingdao | No | 41 11104 LIFE SAVING APPLIANCES (Rescue Boats) No 2 07110 FIRE SAFETY (Fire Fighting Equipment And Appliances) No 3 14402 POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) No 4 07105 FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) No |
| 04 Apr 2025 | Coronel | No | 21 04115 EMERGENCY SYSTEMS (Safe Areas) No 2 18424 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Steam Pipes, Pressure Pipes, Wires (Insulation)) |
| 25 Aug 2024 | El Dekheila | No | 0 |
| 27 May 2024 | Garrucha | No | 1Evaluation Of Crew Performance (Fire Drills) Lack Of Training |
| 03 Oct 2023 | Huelva | No | 5Emergency Systems; 04102 - Emergency Fire Pump And Its Pipes; Not Properly Maintained; Fire Safety; 07110 - Fire Fighting Equipment And Appliances; Not Properly Maintained; Labour Conditions - Accommodation, Recreational Facilities, Food And Catering; 18302 - Sanitary Facilities; Inoperative; Life Saving Appliances; 11119 - Immersion Suits; Not As Required; Other; 99101 - Other Safety In General; Other; |
| 19 Jun 2023 | Mersin | No | 8Fire Safety, 07110 - Fire Fighting Equipment And Appliances, Missing Life Saving Appliances, 11101 - Lifeboats, Missing Safety Of Navigation, 10114 - Voyage Data Recorder (VDR) / Simplified Voyage Data Recorder (S-VDR), Not As Required Safety Of Navigation, 10127 - Voyage Or Passage Plan, Not As Required Safety Of Navigation, 10113 - Automatic Identification System (AIS), Missing Certificate & Documentation - Documents, 01314 - SOPEP, Missing Certificate & Documentation - Documents, 01315 - Oil Record Book, Not As Required Certificate & Documentation - Documents, 01308 - Records Of Seafarers' Daily Hours Of Work Or Rest, Missing |
| 19 Jan 2023 | Callao | No | 0 |
| 20 Oct 2022 | Puerto Patache | No | 21 09131 LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Cold Room) No 2 15150 ISM (ISM) No |
| 17 Oct 2022 | Puerto Patache | No | 2WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) ; LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Cold Room) ; ISM (ISM) |
| 17 Oct 2022 | Puerto Patache | No | 31 03103 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) No 2 09131 LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Cold Room) No 3 15150 ISM (ISM) No |
| 04 Oct 2022 | Puerto Patache | No | 7SAFETY OF NAVIGATION (Pilot Ladders And Hoist/Pilot Transfer Arrangements) (01.10.2022); EMERGENCY SYSTEMS (Crew Familiarisation With Emergency Systems) (01.10.2022); FIRE SAFETY (Fire Fighting Equipment And Appliances) (01.10.2022); EMERGENCY SYSTEMS |
| 28 Jun 2022 | Gunsan | No | 0 |
| 16 Feb 2021 | Rouen | No | 110133, Bridge Operation, Safety Of Navigation, 1208, Lack Of Familiarity, , |