Loading…

| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 19 Dec 2025 | Ventspils | No | 0 |
| 05 Feb 2025 | Norrkoping | No | 0 |
| 15 Oct 2024 | Szczecin | No |
| Date | Type | Details |
|---|---|---|
| 11 Mar 2013 | Engine Fault | Anch with engine problems in 37 04 N 07 32 W 07 Mar 2013. Towed to Algeciras 09 Mar. Still under repair 01 Apr, crew fitting turbo-charger. |
| 8Emergency Systems 04114 - Emergency Source Of Power - Emergency Generator Inoperative Yes Fire Safety 07117 - Jacketed High Pressure Lines And Oil Leakage Alarm Inoperative Yes Fire Safety 07117 - Jacketed High Pressure Lines And Oil Leakage Alarm Not As Required Yes Labour Conditions - Accommodation, Recreational Facilities, Food And Catering 18316 - Water, Pipes, Tanks Not As Required Safety Of Navigation 10116 - Nautical Publications Missing Yes Alarms 08107 - Machinery Controls Alarm Malfunctioning Yes Certificate & Documentation - Ship Certificates 01104 - Cargo Ship Safety Radio (Including Exemption) Not Properly Filled ISM 15150 - ISM Not As Required |
| 29 Nov 2023 | Norrkoping | No | 0 |
| 23 Nov 2022 | Liepaja | No | 0 |
| 08 Sep 2022 | Pozzallo | No | 0 |
| 03 Nov 2021 | Immingham | No | 201326, Stability Information Booklet, Certificate & Documentation - Documents, 1011, Not As Required, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, , |