Vessel
KORMORAN
IMO 9100061
CargoBuilt 1994Active
3,957
Gross tonnageA measure of the vessel's total internal volume (not its weight).
6,177
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
448
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
1994
Year built
Live position & voyage
LIVELoading position…
Particulars
- IMO
- 9100061
- MMSI
- 671274100
- Call sign
- 5VIA7
- Flag
- TG
- Type
- General Cargo
- Length (LOA)
- 108.23 m
- Beam
- 16.4 m
- Home port
- BELIZE CITY
Ownership
- Beneficial owner
- —
- Operator
- —
- Technical manager
- —
- Commercial manager
- —
- Class society
- RI
- Design DWT
- 5,388 t
- Flag
- Belize
- Built
- 1994
Timeline
key events over the vessel's life- Casualty · Engine FaultVessel suffered engine failure while proceeding downstream on the River Danube i
- Special survey
- Built
Surveys & certificates
dry dock & statutory certificates- Last dry dock
- —
- Special survey
- 02 Mar 2021
- IOPP issued
- 07 Feb 2025
- IOPP expires
- 16 Oct 2025
Shipments carried
recent bills of ladingNo shipment records.
Inspections
recent port state control| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 28 Apr 2026 | Aliaga | No | 14Living And Working Conditions - Working Conditions 09223 - Gangway, Accommodation-Ladder Not Properly Maintained Emergency Systems 04107 - Emergency Towing Arrangements And Procedures Not As Required Yes Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Yes Certificate & Documentation - Documents 01320 - Garbage Record Book Not As Required Water/Weathertight Conditions 03108 - Ventilators, Air Pipes, Casings Not Properly Maintained Yes Pollution Prevention - Ballast Water 14802 - Ballast Water Record Book Not Properly Filled Yes Pollution Prevention - Ballast Water 14801 - Ballast Water Management Plan Not Updated Yes Certificate & Documentation - Ship Certificates 01101 - Cargo Ship Safety Equipment (Including Exemption) Entries Missing Yes Emergency Systems 04103 - Emergency, Lighting,Batteries And Switches Insufficient Yes Living And Working Conditions - Working Conditions 09232 - Cleanliness Of Engine Room Insufficient Yes Propulsion And Auxiliary Machinery 13103 - Gauges,Thermometers, Etc Not Properly Maintained Yes Fire Safety 07120 - Means Of Escape Unsafe Yes Life Saving Appliances 11101 - Lifeboats Not Properly Maintained Yes ISM 15150 - ISM Not As Required |
| 13 Mar 2026 | Tripoli | No | 6Structural Conditions 02140 - Towing And Mooring Equipment Not As Required Safety Of Navigation 10116 - Nautical Publications Not Updated Life Saving Appliances 11105 - Rescue Boat Inventory Not As Required Labour Conditions - Accommodation, Recreational Facilities, Food And Catering 18312 - Galley, Handlingroom (Maintenance) Not As Required Fire Safety 07116 - Ventilation Not As Required Living And Working Conditions - Working Conditions 09232 - Cleanliness Of Engine Room Insufficient Total 0 0 0 0 |
| 30 Dec 2025 | Eleusina | No | 518414, Protection Machines/Parts, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1086, Not Properly Maintained,01310, Signs, Indications, Certificate & Documentation - Documents, 1011, Not As Required,18311, Messroom And Recreational Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,18312, Galley, Handlingroom (Maintenance), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required |
| 27 Oct 2025 | Kocaeli | Yes | 27Structural Conditions 02106 - Hull Damage Impairing Seaworthiness Dented Certificate & Documentation - Documents 01315 - Oil Record Book Not As Required Fire Safety 07115 - Fire-Dampers Inoperative Yes Yes Fire Safety 07106 - Fire Detection And Alarm System Not As Required Yes Yes Fire Safety 07110 - Fire Fighting Equipment And Appliances Not As Required Propulsion And Auxiliary Machinery 13102 - Auxiliary Engine Not As Required Emergency Systems 04106 - Emergency Steering Position Com./ Compass Reading Inoperative Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Alarms 08107 - Machinery Controls Alarm Inadequate Propulsion And Auxiliary Machinery 13102 - Auxiliary Engine Not As Required Living And Working Conditions - Working Conditions 09208 - Protection Machinery Unsafe Fire Safety 07199 - Other (Fire Safety) Other ISM 15150 - ISM Not As Required Yes Yes Life Saving Appliances 11105 - Rescue Boat Inventory Not As Required Yes Yes Yes Other Life Saving Appliances 11110 - Stowage And Provision Of Liferafts Not Properly Stowed Yes Yes Yes Life Saving Appliances 11102 - Lifeboat Inventory Not As Required Life Saving Appliances 11101 - Lifeboats Not Properly Maintained Life Saving Appliances 11112 - Launching Arrangements For Survival Craft Improperly Fitted Yes Yes Yes Water/Weathertight Conditions 03107 - Doors Not Properly Maintained Living And Working Conditions - Living Conditions 09112 - Medical Equipment Missing Equipment Pollution Prevention - Marpol Annex V 14501 - Garbage Shipboard Handling Not As Required Water/Weathertight Conditions 03112 - Scuppers, Inlets And Discharges Not As Required Safety Of Navigation 10116 - Nautical Publications Expired Safety Of Navigation 10105 - Magnetic Compass Not Readable Life Saving Appliances 11131 - On Board Training And Instructions Not As Required Pollution Prevention - Marpol Annex V 14501 - Garbage Shipboard Handling Not As Required Total 6 3 0 6 |
| 06 Jun 2025 | El Iskandariya (Alexandria) | No | 3Radio Communications 05109 - VHF Radio Installation Not As Required Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Certificate & Documentation - Documents 01314 - SOPEP Not Updated |
| 05 Jun 2025 | El Iskandariya (Alexandria) | No | 3Radio Communications 05109 - VHF Radio Installation Not As Required Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Certificate & Documentation - Documents 01314 - SOPEP Not Updated |
| 13 May 2025 | Dumyat (Damietta) | No | 9Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Water/Weathertight Conditions 03105 - Covers (Hatchway-, Portable-, Tarpaulins, Etc.) Not As Required Living And Working Conditions - Working Conditions 09223 - Gangway, Accommodation-Ladder Damaged Structural Conditions 02199 - Other (Structural Conditions) Other Structural Conditions 02112 - Hull - Corrosion Corroded Structural Conditions 02113 - Hull - Cracking Buckled Structural Conditions 02199 - Other (Structural Conditions) Other Certificate & Documentation - Ship Certificates 01102 - Cargo Ship Safety Construction (Including Exempt.) Expired Certificate & Documentation - Ship Certificates 01199 - Other (Certificates) Other Total 0 0 0 0 |
| 24 Mar 2025 | Kocaeli | Yes | 15Structural Conditions 02113 - Hull - Cracking Buckled Structural Conditions 02112 - Hull - Corrosion Corroded Living And Working Conditions - Working Conditions 09298 - Other (Accident Prevention) Not Ready For Use Structural Conditions 02199 - Other (Structural Conditions) Other Yes Living And Working Conditions - Working Conditions 09223 - Gangway, Accommodation-Ladder Damaged Certificate & Documentation - Documents 01312 - Thickness Measurement Report Not As Required Safety Of Navigation 10199 - Other (Navigation) Other Fire Safety 07115 - Fire-Dampers Inoperative Yes Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Water/Weathertight Conditions 03107 - Doors Not Properly Maintained Water/Weathertight Conditions 03105 - Covers (Hatchway-, Portable-, Tarpaulins, Etc.) Not As Required Other Pollution Prevention - Ballast Water 14802 - Ballast Water Record Book Missing Safety Of Navigation 10111 - Charts Not Updated Safety Of Navigation 10109 - Lights, Shapes, Sound-Signals Inoperative Total 2 0 0 0 |
| 13 Feb 2025 | Tripoli | No | 4Safety Of Navigation 10105 - Magnetic Compass Inoperative Safety Of Navigation 10128 - Navigation Bridge Visibility Not As Required Propulsion And Auxiliary Machinery 13199 - Other (Machinery) Other Pollution Prevention - Marpol Annex III 14302 - Marking And Labelling Missing Total 0 0 0 0 |
| 15 Nov 2024 | Pivdennyi | No | 21 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Electrical) Rectify Deficiency Before Departure Deficiency Rectified 2 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Electrical) Rectify Deficiency Before Departure Deficiency Rectified |
| 31 Jul 2024 | Tripoli | No | 8Life Saving Appliances 11101 - Lifeboats Missing Propulsion And Auxiliary Machinery 13199 - Other (Machinery) Other Certificate & Documentation - Documents 01314 - SOPEP Not Updated Certificate & Documentation - Documents 01310 - Signs, Indications Not As Required Living And Working Conditions - Living Conditions 09112 - Medical Equipment Expired Living And Working Conditions - Working Conditions 09297 - Other (Working Space ILO) Damaged Structural Conditions 02105 - Steering Gear Not As Required Labour Conditions - Accommodation, Recreational Facilities, Food And Catering 18302 - Sanitary Facilities Not As Required Total 0 0 0 0 |
| 21 Mar 2024 | Karasu | No | 10LIFE SAVING APPLIANCES (Inflatable Liferafts); FIRE SAFETY (International Shore-Connection) ; FIRE SAFETY (Means Of Escape); PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) ; CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Log-Books/Compulsory Entries) ; CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Minimum Hours Of Rest); SAFETY OF NAVIGATION (Navigation Records) ; POLLUTION PREVENTION - MARPOL ANNEX I (Other (MARPOL Annex I)) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Ventilation (Working Spaces)) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Obstruction/Slipping, Etc.) |
| 30 Dec 2023 | Galati | No | 511108, Inflatable Liferafts, Life Saving Appliances, 1046, Not Properly Marked, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 07118, International Shore-Connection, Fire Safety, 1011, Not As Required, 07120, Means Of Escape, Fire Safety, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required |
| 14 Dec 2023 | Trabzon | No | 2LIFE SAVING APPLIANCES (Stowage And Provision Of Liferafts) Rectify Deficiency Before Departure Deficiency Rectified 2 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) Rectify Deficiency Before Departure Deficiency Rectified |
| 28 Oct 2023 | Beirut | No | 7Living And Working Conditions - Living Conditions - Medical Equipment Missing Equipment ; Structural Conditions - Closing Devices/Watertight Doors Damaged ; Living And Working Conditions - Working Conditions - Other (Working Space ILO) Not As Required ; Living And Working Conditions - Living Conditions - Lighting (Accommodation) Inoperative ; Propulsion And Auxiliary Machinery - Other (Machinery) Other ; Life Saving Appliances - Lifeboats Not Properly Marked ; Living And Working Conditions - Working Conditions - Other (Working Space ILO) Not As Required |
| 16 Aug 2023 | Reni | No | 0 |
| 06 Jun 2023 | Tripoli | No | 7Living And Working Conditions - Working Conditions, , 09223 - Gangway, Accommodation-Ladder, , Unsafe, , , , , , , , , , Certificate & Documentation - Documents, , 01306 - Shipboard Working Arrangements, , Not Properly Filled, , , , , , , , , , Water/Weathertight Conditions, , 03108 - Ventilators, Air Pipes, Casings, , Not Properly Maintained, , , , , , , , , , Fire Safety, , 07115 - Fire-Dampers, , Not As Required, , , , , , , , , , Emergency Systems, , 04108 - Muster List, , Not Updated, , , , , , , , , , Life Saving Appliances, , 11101 - Lifeboats, , Inoperative, , , , , , , , , , Living And Working Conditions - Working Conditions, , 09207 - Obstruction/Slipping, Etc., , Slippery, , |
| 19 May 2023 | Galati | No | 905115, Radio Log (Diary), Radio Communications, 1011, Not As Required, 10106, Compass Correction Log, Safety Of Navigation, 1011, Not As Required, 14502, Placards, Pollution Prevention - Marpol Annex V, 100Missing7116, Ventilation, Fire Safety, 100Missing2108, Electrical Installations In General, Structural Conditions, 1027, Unsafe2107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required712Means Of Escape, Fire Safety, 1011, Not As Required, 13103, Gauges,Thermometers, Etc, Propulsion And Auxiliary Machinery, 1011, Not As Required, 1515ISM, ISM, 1011, Not As Required |
| 19 May 2023 | Galati | No | 11LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Lighting (Working Spaces)) ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Access / Structural Features (Ship)) ; PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc) ; ISM (ISM) ; RADIO COMMUNICATIONS (Radio Log (Diary)) ; SAFETY OF NAVIGATION (Compass Correction Log) ; POLLUTION PREVENTION - MARPOL ANNEX V (Placards) ; FIRE SAFETY (Ventilation ) ; STRUCTURAL CONDITIONS (Electrical Installations In General) ; STRUCTURAL CONDITIONS (Ballast, Fuel And Other Tanks) ; FIRE SAFETY (Means Of Escape) |
| 18 Apr 2023 | Izmail | No | 0 |
Casualties
| Date | Type | Details |
|---|---|---|
| 15 Sep 2021 | Engine Fault | Vessel suffered engine failure while proceeding downstream on the River Danube in the Sulina Canal, enroute from Reni in Ukraine to Tripoli. It lost control and ran onto the bank in the Tulcea area of Romania, coming into contact with three berthed leisure catamarans. The catamarans sustained damage and canal traffic was blocked for abound 2 hours. |