BoatDB
Vessel

LEGEND

IMO 9460289
CargoBuilt 2010Active
23,494
Gross tonnageA measure of the vessel's total internal volume (not its weight).
33,693
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2010
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9460289
MMSI
352003762
Call sign
3E5861
Flag
PA
Type
Bulk Carrier
Length (LOA)
180 m
Beam
30 m
Home port
MAJURO

Ownership

Beneficial owner
Operator
Technical manager
Commercial manager
Class society
NK
Design DWT
33,693 t
Flag
Marshall Islands
Built
2010

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Casualty · Collision
    Norah which was moored at Drapetzona, was blown by strong winds c/w Aqua Solutio
  4. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
03 Oct 2027
Special survey
03 Oct 2029
IOPP issued
20 Sep 2024
IOPP expires
20 May 2029

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
25 Dec 2025ChornomorskNo51 STRUCTURAL CONDITIONS (Decks - Corrosion) (17.04.2025) Other (Specify) Deficiency Rectified 2 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) (17.04.2025) Other (Specify) Deficiency Rectified 3 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (SOPEP) Rectify Deficiency Before Departure Deficiency Rectified 4 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Oil Record Book) Rectify Deficiency Before Departure Deficiency Rectified 5 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) Rectify Deficiency Before Departure Deficiency Rectified
25 Nov 2025KocaeliYes15Fire Safety 07105 - Fire Doors/Openings In Fire-Resisting Divisions Not As Required Yes Yes Certificate & Documentation - Ship Certificates 01123 - Continuous Synopsis Record Missing Pollution Prevention - Ballast Water 14899 - Other BWM Other Yes Yes Safety Of Navigation 10116 - Nautical Publications Expired Yes Safety Of Navigation 10127 - Voyage Or Passage Plan Not As Required Fire Safety 07106 - Fire Detection And Alarm System Not As Required Yes Yes Life Saving Appliances 11112 - Launching Arrangements For Survival Craft Not As Required Yes Yes Propulsion And Auxiliary Machinery 13102 - Auxiliary Engine Not As Required Structural Conditions 02117 - Decks - Corrosion Corroded Yes Yes Water/Weathertight Conditions 03107 - Doors Not Properly Maintained Yes Safety Of Navigation 10101 - Pilot Ladders And Hoist/Pilot Transfer Arrangements Unsafe Water/Weathertight Conditions 03105 - Covers (Hatchway-, Portable-, Tarpaulins, Etc.) Corroded Yes Pollution Prevention - Marpol Annex I 14199 - Other (MARPOL Annex I) Other Yes Certificate & Documentation - Documents 01312 - Thickness Measurement Report Not As Required ISM 15199 - Other (ISM) Other Yes Yes Total 6 0 0 10
13 May 2025AliagaNo5Pollution Prevention - Marpol Annex V 14501 - Garbage Shipboard Handling Not As Required Pollution Prevention - Ballast Water 14802 - Ballast Water Record Book Not Properly Filled Living And Working Conditions - Working Conditions 09236 - Legal Documentation On Work And Rest Hours Not As Required Living And Working Conditions - Working Conditions 09223 - Gangway, Accommodation-Ladder Not Properly Maintained Pollution Prevention - Marpol Annex III 14302 - Marking And Labelling Missing Total 0 0 0 0
17 Apr 2025Taman'No61 SAFETY OF NAVIGATION (Nautical Publications) Rectify Deficiency Before Departure Deficiency Rectified 2 WATER/WEATHERTIGHT CONDITIONS (Covers (Hatchway-, Portable-, Tarpaulins, Etc.)) Rectify Deficiency Before Departure Deficiency Rectified 3 STRUCTURAL CONDITIONS (Decks - Corrosion) Other (Specify) 4 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) Other (Specify) 5 POLLUTION PREVENTION - MARPOL ANNEX I (Oil And Oily Mixtures From Machinery Spaces) Rectify Deficiency Before Departure Deficiency Rectified 6 LIFE SAVING APPLIANCES (Lifeboat Inventory) Rectify Deficiency Before Departure Deficiency Rectified
11 Mar 2025Castellon De La PlanaNo501214, Endorsement By Flagstate, Certificate & Documentation - Crew Certificates, 1004, Expired,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1086, Not Properly Maintained,13106, Insulation Wetted Through (Oil), Propulsion And Auxiliary Machinery, 1036, Insufficient,10114, Voyage Data Recorder (VDR) / Simplified Voyage Data Recorder (S-VDR), Safety Of Navigation, 1011, Not As Required,18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1016, Dirty
12 Feb 2025ChornomorskNo31 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) (10.08.2024) Detainable Deficiency Other (Specify) Deficiency Rectified 2 ISM (ISM) (10.08.2024) Corrective Action Taken On The ISM System By The Company Is Required Within 3 Months Deficiency Rectified 3 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) (10.08.2024) Other (Specify) Deficiency Rectified
21 Jan 2025BeirutNo0
12 Oct 2024Chah BaharNo71 07122 Fire Control Plan 2 03103 Railing, Gangway, Walkway And Means For Safe Passage 3 01101 Cargo Ship Safety Equipment (Including Exemption) 4 01322 Conformance Test Report 5 18321 Heating, Air Conditioning And Ventilation 6 14503 Garbage Management Plan 7 14801 Ballast Water Management Plan
10 Aug 2024NovorossiiskYes101 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) Detainable Deficiency Other (Specify) 2 ISM (ISM) Corrective Action Taken On The ISM System By The Company Is Required Within 3 Months 3 WATER/WEATHERTIGHT CONDITIONS (Covers (Hatchway-, Portable-, Tarpaulins, Etc.)) Rectify Deficiency Before Departure Deficiency Rectified 4 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Steam Pipes, Pressure Pipes, Wires (Insulation)) Rectify Deficiency Before Departure Deficiency Rectified 5 LIFE SAVING APPLIANCES (Rescue Boat Inventory) Rectify Deficiency Before Departure Deficiency Rectified 6 WATER/WEATHERTIGHT CONDITIONS (Railing, Gangway, Walkway And Means For Safe Passage) Other (Specify) 7 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Ropes And Wires) Rectify Deficiency Before Departure Deficiency Rectified 8 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Electrical) Rectify Deficiency Before Departure Deficiency Rectified 9 ALARMS (Machinery Controls Alarm) Rectify Deficiency Before Departure Deficiency Rectified 10 LIFE SAVING APPLIANCES (Lifeboats) Rectify Deficiency Before Departure Deficiency Rectified
20 Jul 2024Lavrion (Laurium)No13Water Level Indicator Not As Required ; Sewage Treatment Plant Not As Required ; Pilot Ladders And Hoist/Pilot Transfer Arrangements Unsafe ; Food Segregation Not Adequate ; Decks - Corrosion Corroded ; Garbage Management Plan Not As Required ; Electronic Charts (ECDIS) Not As Required ; Emergency, Lighting,Batteries And Switches Not As Required Other ; Messroom And Recreational Facilities Not As Required ; Medical Fitness Not As Required ; Radio Log (Diary) Not As Required ; ISM Not As Required
20 Jul 2024Laurium (Lavrion)No1204113, Water Level Indicator, Emergency Systems, 1011, Not As Required,14402, Sewage Treatment Plant, Pollution Prevention - Marpol Annex IV, 1011, Not As Required,10101, Pilot Ladders And Hoist/Pilot Transfer Arrangements, Safety Of Navigation, 1027, Unsafe,18319, Food Segregation, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1215, Not Adequate,02117, Decks - Corrosion, Structural Conditions, 1029, Corroded,14503, Garbage Management Plan, Pollution Prevention - Marpol Annex V, 1011, Not As Required,10112, Electronic Charts (ECDIS), Safety Of Navigation, 1011, Not As Required,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1011, Not As Required,18311, Messroom And Recreational Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,18103, Medical Fitness, Labour Conditions - Minimum Requirements For Seafarers, 1011, Not As Required,05115, Radio Log (Diary), Radio Communications, 1011, Not As Required,15150, ISM, ISM, 1011, Not As Required
08 Jul 2024BeirutNo0
20 Oct 2023CoronelNo3FIRE SAFETY (Personal Equipment For Fire Safety); LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition); PROPULSION AND AUXILIARY MACHINERY (Gauges,Thermometers, Etc)
03 Jun 2023New OrleansNo1System: 02 - Structural Conditions Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: Ships Shall Be Designed, Constructed And Maintained In Compliance With The Structural, Mechanical And Electrical Requiremen
28 Dec 2022SfaxNo0
07 Oct 2022Gent (Ghent)No1204101, Public Address System, Emergency Systems, 1082, Inoperative, 02107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required, 13104, Bilge Pumping Arrangements, Propulsion And Auxiliary Machinery, 1011, Not As Required, 18424, Steam Pipes, Pressure Pipes, Wires (Insulation), Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 11124, Embarkation Arrangement Survival Craft, Life Saving Appliances, 1000, Missing, 04116, Means Of Communication Between Safety Centre And Other Control Stations, Emergency Systems, 1011, Not As Required, 18312, Galley, Handlingroom (Maintenance), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1025, Not Hygienic, 04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required, 04121, Crew Familiarization With Emergency Systems, Emergency Systems, 1011, Not As Required, 07111, Personal Equipment For Fire Safety, Fire Safety, 1011, Not As Required, 15150, ISM, ISM, 1011, Not As Required,
21 Jan 2022MykolaivNo0
22 Nov 2021RostockNo1518420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 07115, Fire-Dampers, Fire Safety, 1011, Not As Required, 03110, Manholes/Flush Scuttles, Water/Weathertight Conditions, 1011, Not As Required, 15150, ISM, ISM, 1011, Not As Required, 07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative, 18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1025, Not Hygienic, 18407, Lighting (Working Spaces), Labour Conditions - Health Protection, Medical Care, Social Security, 1082, Inoperative, 18313, Cleanliness, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1016, Dirty, 18409, Dangerous Areas, Labour Conditions - Health Protection, Medical Care, Social Security, 1026, Damaged, 13199, Other (Machinery), Propulsion And Auxiliary Machinery, 1238, Other, 04117, Functionality Of Safety Systems, Emergency Systems, 1031, Incomplete, 02105, Steering Gear, Structural Conditions, 1011, Not As Required, 03105, Covers (Hatchway-, Portable-, Tarpaulins, Etc.), Water/Weathertight Conditions, 1026, Damaged, 08108, UMS - Alarms, Alarms, 1082, Inoperative, 14403, Sewage Comminuting And Disinfecting System, Pollution Prevention - Marpol Annex IV, 1011, Not As Required,

Casualties

DateTypeDetails
07 Mar 2021CollisionNorah which was moored at Drapetzona, was blown by strong winds c/w Aqua Solution, which was moored port side aft of Norah, causing minor material damage, 07 Mar 2021. Keratsini Port banned departure of both vessels until it is seaworthy.