BoatDB
Vessel

LEO

IMO 9167679
CargoBuilt 1997Active
4,690
Gross tonnageA measure of the vessel's total internal volume (not its weight).
6,175
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
1997
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9167679
MMSI
341289002
Call sign
V4YU6
Flag
KN
Type
General Cargo
Length (LOA)
96.7 m
Beam
17.4 m
Home port

Ownership

Beneficial owner
Operator
Technical manager
Altair Shipping
Commercial manager
Class society
KR
Design DWT
6,803 t
Flag
Sierra Leone
Built
1997

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Sold
    $1.5M
  4. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
26 Jul 2028
Special survey
30 Mar 2030
IOPP issued
26 Jul 2025
IOPP expires
08 Mar 2030

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
25 Jan 2026Suez CanalNo2Propulsion And Auxiliary Machinery 13102 - Auxiliary Engine Not As Required Fire Safety 07106 - Fire Detection And Alarm System Not As Required
22 Aug 2025BartinYes121 EMERGENCY SYSTEMS (Abandon Ship Drills) Detainable Deficiency Deficiency Rectified 2 PROPULSION AND AUXILIARY MACHINERY (Propulsion Main Engine) Detainable Deficiency Deficiency Rectified 3 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Before Departure Deficiency Rectified 4 PROPULSION AND AUXILIARY MACHINERY (Bilge Pumping Arrangements) Rectify Deficiency Before Departure Deficiency Rectified 5 ALARMS (Machinery Controls Alarm) Rectify Deficiency Before Departure Deficiency Rectified 6 POLLUTION PREVENTION - MARPOL ANNEX V (Garbage Shipboard Handling) Rectify Deficiency Before Departure Deficiency Rectified 7 EMERGENCY SYSTEMS (Emergency Fire Pump And Its Pipes) Detainable Deficiency Deficiency Rectified 8 LIFE SAVING APPLIANCES (Launching Arrangements For Survival Craft) Detainable Deficiency Deficiency Rectified 9 WATER/WEATHERTIGHT CONDITIONS (Windows, Sidescuttles And Deadlights) Rectify Deficiency Before Departure Deficiency Rectified 10 WATER/WEATHERTIGHT CONDITIONS (Covers (Hatchway-, Portable-, Tarpaulins, Etc.)) Detainable Deficiency Deficiency Rectified 11 POLLUTION PREVENTION - BALLAST WATER (Crew Training And Familiarization) Detainable Deficiency Deficiency Rectified 12 ISM (ISM) Corrective Action Taken On The ISM System By The Company Is Required Within 3 Months
24 Jun 2025OdesaNo51 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (SOPEP) Rectify Deficiency Before Departure Deficiency Rectified 2 FIRE SAFETY (Fire Control Plan) Rectify Deficiency Before Departure Deficiency Rectified 3 SAFETY OF NAVIGATION (Navigation Records) Rectify Deficiency Before Departure Deficiency Rectified 4 LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) Rectify Deficiency Before Departure Deficiency Rectified 5 LIVING AND WORKING CONDITIONS - LIVING CONDITIONS (Medical Equipment ) Rectify Deficiency Before Departure Deficiency Rectified
13 Jun 2025PiraeusNo1103108, Ventilators, Air Pipes, Casings, Water/Weathertight Conditions, 1086, Not Properly Maintained,03107, Doors, Water/Weathertight Conditions, 1086, Not Properly Maintained,04102, Emergency Fire Pump And Its Pipes, Emergency Systems, 1011, Not As Required,11104, Rescue Boats, Life Saving Appliances, 1033, Missing Equipment,18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1011, Not As Required,13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required,07110, Fire Fighting Equipment And Appliances, Fire Safety, 1011, Not As Required,10127, Voyage Or Passage Plan, Safety Of Navigation, 1031, Incomplete,18312, Galley, Handlingroom (Maintenance), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required,14501, Garbage Shipboard Handling, Pollution Prevention - Marpol Annex V, 1011, Not As Required
14 Apr 2025Al AdabiyahNo1Labour Conditions - Health Protection, Medical Care,Social Security 18499 - Other (Health Protection, Medical Care) Other
24 Nov 2023KalamataNo702117, Decks - Corrosion, Structural Conditions, 1011, Not As Required, 18302, Sanitary Facilities, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 01320, Garbage Record Book, Certificate & Documentation - Documents, 1011, Not As Required, 01305, Log-Books/Compulsory Entries, Certificate & Documentation - Documents, 1002, Entries Missing, 14802, Ballast Water Record Book, Pollution Prevention - Ballast Water, 1003, Not Properly Filled, 15150, ISM, ISM, 1011, Not As Required, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,
06 Nov 2023ReniNo0
18 May 2023Alexandria (Egypt)No5Safety Of Navigation - Nautical Publications Not Updated ; Emergency Systems - Emergency Towing Arrangements And Procedures Missing ; Propulsion And Auxiliary Machinery - Auxiliary Engine Not As Required ; Labour Conditions - Accommodation, Recreational Facilities, Food And Catering - Hospital Accomodation (Sickbay) Not As Required ; Emergency Systems - Emergency, Lighting,Batteries And Switches Not As Required
13 Feb 2023MangaloreNo0
08 Feb 2023MangaloreNo71 03102 Freeboard Marks 2 04103 Emergency, Lighting,Batteries And Switches 3 07199 Other (Fire Safety) 4 13199 Other (Machinery) 5 14502 Placards 6 07114 Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces 7 11117 Lifebuoys Inc
18 Aug 2021MariupolNo5SAFETY OF NAVIGATION (Charts); AFETY OF NAVIGATION (Lights, Shapes, Sound-Signals); FIRE SAFETY (Fire Detection And Alarm System); LIFE SAVING APPLIANCES (Lifeboats); LIFE SAVING APPLIANCES (Fast Rescue Boats)
02 Feb 2021SeteNo601306, Shipboard Working Arrangements, Certificate & Documentation - Documents, 1000, Missing, 14802, Ballast Water Record Book, Pollution Prevention - Ballast Water, 1003, Not Properly Filled, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 01209, Manning Specified By The Minimum Safe Manning Doc, Certificate & Documentation - Crew Certificates, 1011, Not As Required, 05111, Satellite EPIRB 406MHz/1.6GHz, Radio Communications, 1082, Inoperative, 10111, Charts, Safety Of Navigation, 1000, Missing,, 0

Sale & demolition history

reported transactions & recycling
DateEventPriceReported sale price in US$ millions.Buyer
27 Feb 2018 Reported SoldNULL$1.5M