Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 10 Dec 2025 | Rotterdam | No | 610109, Lights, Shapes, Sound-Signals, Safety Of Navigation, 1011, Not As Required,18324, Cold Room, Cold Room Cleanliness, Cold Room Temperature, Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1025, Not Hygienic,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1082, Inoperative,14811, Ballast Water Management System, Pollution Prevention - Ballast Water, 1100, Malfunctioning,07113, Fire Pumps And Its Pipes, Fire Safety, 1082, Inoperative,15150, ISM, ISM, 1011, Not As Required |
| Date | Type | Details |
|---|---|---|
| 17 Jun 2025 | Piracy | Four perpetrators were spotted on the stern deck of a ship, a search was conducted with no perpetrators found onboard. All crew members were accounted for and no theft was reported. Safety broadcasts were initiated, and the ship resumed its voyage to Singapore PEBGB. |
| Date | Event | PriceReported sale price in US$ millions. | Buyer |
|---|---|---|---|
| 26 Sep 2024 |
| 16 Dec 2024 | Corpus Christi | No | 5System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07123 - Operation Of Fire Protection Systems Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: A FIXED HIGH-EXPANSION FOAM FIRE EXTINGUISHING SYSTEM COMPLYING WITH THE PROVISIONS OF THE FSS CODE. A FIXED DECK FOAM-FIRE EXTINGUISHING SYSTEM SHALL BE PROVIDED COMPLYING WITH THE FSS CODE. THE MEANS OF CONTROLLING THE SYSTEM SHALL BE SIMPLE TO OPERATE. DUPLICATE INTRUCTIONS FOR AUTOMATIC AND MANUAL RELEASE OF ALL FIXED FIRE-FIGHTING FOAM ARE POSTED AT THE FOAM STATION. THE INTRUCTIONS DO NOT MATCH ON ANOTHER. BOTH THE 3/E AND C/E MISSED STEPS AND HAD DIFFICULTY FINDING VALUES ON THE INTRUCTIONS. BOTH ENGINEERS WERE ALLOWED TO USE THE PLANS FOR SIMULATED RELEASE BUT FAILED TO SUCCESSFULLY DEMONSTRATE IN EXCESS OF 10 MINUTES. 74SOLAS(04)II-2/10.4.1.1.2 AND II-2/10.8.1.1 FSS CODE 6.3.1.12 AND 6.4.2.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/17/2024 12:00:00 AM Resolution Description: Attended The Vessel With Class DNV And Observed Corrected Instructions Posted. System: 08 - Alarms Sub-System: N/A - No Subsystem Component: 08199 - Other (Alarms) Cause: Action: 10 - Deficiency Rectified Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: A SYSTEM FOR CONTINUOUSLY MONITORING THE CONCENTRATION OF HYDROCARBON GASES SHALL BE FITTED. WHEN HYDROCARBON GASES REACH A PRESET LEVEL A CONTINUOUS AUDIBLE AND VISIBLE ALARM SHALL BE EFFECTED IN THE CARGO CONTROL ROOM. CREW TOOK OVER 2 HOURS TO SUCCESSFULLY TEST THE FIXED GAS DETECTION FOR THE CARGO PUMP ROOM. CREW DISCOVERED PRESSURE SENSOR BEFORE FLOW METER PARTIALLY BLOCKED WITH DEBRIS. 74SOLAS(04) II-2/4.5.10.1.3 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/16/2024 12:00:00 AM Resolution Description: Corrected On The Spot. Crew Troubleshooted And Discovered Debris In Flow Meter Sensor. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07125 - Evaluation Of Crew Performance (Fire Drills) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: CREW MEMBERS SHALL BE TRAINED TO BE FAMILIAR WITH THE ARRANGEMENTS OF THE SHIP AS WELL AS THE LOCATION AND OPERATION OF ANY FIRE FIGHTING SYSTEMS AND APPLIANCES THAT THEY MAY BE CALLED UPON TO USE. AFTER SEEING DUPLICATE INTRUCTIONS FOR THE RELEASE OF BOTH HIGH AND LOW EXPANSION FOAM, PSCO WITNESSED BOTH THE 3/E AND C/E FAIL TO PROPERLY DEMONSTRATE THE RELEASE OF FOAM TO THE CARGO PUMP ROOM AND TO DECK. 74SOLAS(04) II-2/15.2.2.1 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/17/2024 12:00:00 AM Resolution Description: Attended Vessel With Class DNV And Witnessed Satisfactory Simulated Releases. System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07123 - Operation Of Fire Protection Systems Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: FIRE-FIGHTING SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. WHILE WITNESSING ENGINEERS SIMULATING FOAM RELEASES IN THE FOAM STATION, VALVES LABELED "A" FROM ENGINE ROOM SUPPLY / "2" TO SUPPLY DECK FOAM / BOTH INLET AND OUTLET 1/4 TURN VALVES BETWEEN DIAPHRAGM FOR DECK FOAM WERE FOUND IN THE OPPOSITE POSITION OF THE INTRUCTIONS. THIS COULD ALLOW THE OPERATOR TO INADVERTANTLY OPEN OR CLOSE THE VALVE IN THE WRONG POSITION 74SOLAS(04) II-2/14.2.1.2 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/17/2024 12:00:00 AM Resolution Description: Attended The Vessel With Class DNV To Insure Valve Position Matched Instructions Posted. System: 06 - Cargo Operations Including Equipment Sub-System: N/A - No Subsystem Component: 06199 - Other (Cargo) Cause: Action: 17 - Rectify Deficiencies Prior To Departure Action Code: A - To The Satisfaction Of RO/RSO Description Of Deficiency: IN TANKERS, ELECTRICAL EQUIPMENT SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. 04 EXPLOSION PROOF LIGHTS WERE FOUND CRACKED. 03 IN CARGO PUMP ROOM AND 01 IN DECK STORES FOR SOPEP. 74SOLAS(04)II-1/45.11 Due Date: N/A Deficiency Resolved? Yes Resolved Date: 12/17/2024 12:00:00 AM Resolution Description: Attended Vessel With Class DNV And Verified Explosion Proof Lenses Have Been Replaced. |
| 16 Jun 2023 | Quintero | No | 0 |
| 18 May 2022 | Mongstad | No | 201315, Oil Record Book, Certificate & Documentation - Documents, 1002, Entries Missing, 07120, Means Of Escape, Fire Safety, 1011, Not As Required, |
| 26 Jan 2022 | Arzew | No | 0 |
| 07 Jul 2021 | Sines | No | 0 |
| $43.37M |
| Unknown |