Loading…
| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 18 Jun 2026 | Vanasadam | No | 0 |
| 15 Dec 2025 | Salaverry | No | 0 |
| 14 Oct 2025 | Izmir | No |
| 0 |
| 19 Dec 2024 | Salaverry | No | 0 |
| 24 Apr 2024 | Giardini Naxos | No | 0 |
| 18 Dec 2023 | Callao | No | 0 |
| 30 Nov 2023 | San Juan, Puerto Rico | No | 5System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: Every Crew Member W/Assigned Emergency Duties Shall Be Familiar W/These Duties Before The Voyage Begins. PSCO Discovered That Stairwell Guides Were Unfamiliar W/Basic Emergency Knowledge During Abandon Ship Drills. Additionally PSCO Discovered Lifeboat Crew Member Were Unfamiliar W/Their Duties And Emergency Procedures, To Include And Not Limited To Emergency Fuel Shut Off Valve Location, Procedures To Engage Emergency Steering, And Location Of Provisions. 74 SOLAS (20) III/19.2.1 Due Date: N/A Deficiency Resolved? No Resolved Date: N/A Resolution Description: N/A System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Improper/Lack Of Maintenance Description Of Deficiency: Fire Doors In Main Vertial Zone Bulkheads, Galley Boundaries And Stairway Enclosures, The Approximate Time Of Closure For Hinged Fire Doors Shall Be No More Than 40s And No Less Than 10s From The Beginning Of Their Movement. PSCO Observed Fire Screen Door 12.5.07 Closed Faster Than 10s. Additionally, Fire Screen Door 14.3.01 Did Not Latch Properly. 74 SOLAS (20) II-2/9.4.1.1.5.2 Due Date: 11/30/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 11/30/2023 12:00:00 AM Resolution Description: N/A System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Improper Installation Description Of Deficiency: Structural Fire Protection, Including Fire-Resisting Divisions, And Protection Of Openings And Penetrations In These Divisions, Shall Be Kept In Good Order So As To Ensure Their Required Performance If A Fire Occurs. PSCO Observed Trash Cans Blocking The Closing Of The Roller Shutter Fire Door At The Grill/Fryer In The Terrace Cafe. 74 SOLAS (20) II-2/14.2.1.1.1 Due Date: 11/30/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 11/30/2023 12:00:00 AM Resolution Description: N/A System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Design Flaw Description Of Deficiency: The Construction Of Doors And Door Frames In 'A' Class Divisions, W/The Means Of Securing Them When Closed, Shall Provide Resistance To Fire As Well As The Passage Of Smoke And Flame Equivalent To That Of The Bulkheads In Which The Doors Are Situated. PSCO Observed Several 'A' Class Fire Doors Missing Striker Plates, And Multiple Others Had Frames That Were Not Capable To Maintain Fire Integrity. 74 SOLAS (20) II-2/9.4.1.1.2 Due Date: 12/30/2023 12:00:00 AM Deficiency Resolved? No Resolved Date: N/A Resolution Description: N/A System: 07 - Fire Safety Sub-System: N/A - No Subsystem Cause: Improper Installation Description Of Deficiency: The Following Functional Requirements Shall Be Met Escape Routes Shall Be Maintained In A Safe Condition, Clear Of Obstacles. PSCO Observed Pallets Of Garbage Obstructing An Escape Route In The Garbage Room. Additionally PSCO Discovered A Steel Gangway Blocking Escape Route To Tender Station In The Vicinity Of Fire Screen Door 4.3.14. Another Escape Route Leading From The Spa Staff Area Into The Weight Room Was Blocked By A Spin Bike. 74 SOLAS (20) II-2/13.1.2 Due Date: 11/30/2023 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 11/30/2023 12:00:00 AM Resolution Description: N/A |
| 18 Apr 2023 | Motril | No | 0 |
| 31 Jan 2023 | Punta Arenas | No | 0 |
| 06 Apr 2022 | Valletta | No | 101220, Seafarers' Employment Agreement (SEA), Certificate & Documentation - Crew Certificates, 1003, Not Properly Filled, |
| 16 Mar 2021 | Piombino | No | 0 |