Loading…

| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 27 Jun 2025 | Ancona | No | 1102102, Damage Control Plan, Structural Conditions, 1179, Not Updated,01113, Minimum Safe Manning Document, Certificate & Documentation - Ship Certificates, 1011, Not As Required,01124, International Air Pollution Cert., Certificate & Documentation - Ship Certificates, 1003, Not Properly Filled,03112, Scuppers, Inlets And Discharges, Water/Weathertight Conditions, 1086, Not Properly Maintained,07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1100, Malfunctioning,07114, Remote Means Of Control (Opening,Pumps,Ventilation,Etc.) Machinery Spaces, Fire Safety, 1011, Not As Required,04108, Muster List, Emergency Systems, 1009, Not Approved,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1082, Inoperative,04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1036, Insufficient,02101, Closing Devices/Watertight Doors, Structural Conditions, 1011, Not As Required,11118, Lifejackets Incl.Provision And Disposition, Life Saving Appliances, 1011, Not As Required |
| Date | Type | Details |
|---|---|---|
| 24 Oct 2009 | Beached/Grounded | Grounded on Sit island between Sibenika and Zadar morning of 24 Oct 2009. Considerable damage to forepart of vessel. Passengers taken off. Investigation under way. Still aground 01 Nov. Smit salvage currently on scene with hydraulic equip. |
| 04 Oct 2024 | Ancona | No | 1202101, Closing Devices/Watertight Doors, Structural Conditions, 1011, Not As Required,01326, Stability Information Booklet, Certificate & Documentation - Documents, 1011, Not As Required,04108, Muster List, Emergency Systems, 1179, Not Updated,14614, Sulphur Oxides, Pollution Prevention - Marpol Annex VI, 1011, Not As Required,07199, Other (Fire Safety), Fire Safety, 1238, Other,07199, Other (Fire Safety), Fire Safety, 1238, Other,11131, On Board Training And Instructions, Life Saving Appliances, 1011, Not As Required,07115, Fire-Dampers, Fire Safety, 1011, Not As Required,07115, Fire-Dampers, Fire Safety, 1011, Not As Required,10116, Nautical Publications, Safety Of Navigation, 1004, Expired,10135, Monitoring Of Voyage Or Passage Plan, Safety Of Navigation, 1011, Not As Required,04101, Public Address System, Emergency Systems, 1082, Inoperative,0 |
| 03 May 2024 | Ancona | No | 9Emergency Systems; 04103 - Emergency, Lighting,Batteries And Switches; Inoperative; Emergency Systems; 04103 - Emergency, Lighting,Batteries And Switches; Missing; Fire Safety; 07105 - Fire Doors/Openings In Fire-Resisting Divisions; Malfunctioning; Emergency Systems; 04101 - Public Address System; Inoperative; Certificate & Documentation - Crew Certificates; 01211 - Cert For Personnel On Survival Craft & Rescue Boat; Missing; Certificate & Documentation - Ship Certificates; 01108 - Load Lines (Including Exemption); Invalid; Certificate & Documentation - Ship Certificates; 01117 - International Oil Pollution Prevention (IOPP); Invalid; Certificate & Documentation - Ship Certificates; 01124 - International Air Pollution Cert.; Invalid; Certificate & Documentation - Ship Certificates; 01119 - International Sewage Pollution Prevention Cert.; Invalid |
| 07 Sep 2023 | Ancona | No | 1605110, Facilities For Reception Of Marine Safety Inform., Radio Communications, 1011, Not As Required, 01209, Manning Specified By The Minimum Safe Manning Doc, Certificate & Documentation - Crew Certificates, 1011, Not As Required, 04121, Crew Familiarization With Emergency Systems, Emergency Systems, 1011, Not As Required, 11108, Inflatable Liferafts, Life Saving Appliances, 1053, Broken Container, 07125, Evaluation Of Crew Performance (Fire Drills), Fire Safety, 1091, Lack Of Training, 04104, Low Level Lighting In Corridors, Emergency Systems, 1011, Not As Required, 07120, Means Of Escape, Fire Safety, 1011, Not As Required, 04101, Public Address System, Emergency Systems, 1000, Missing, 18420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1100, Malfunctioning, 07122, Fire Control Plan, Fire Safety, 1112, Wrong Information, 01211, Cert For Personnel On Survival Craft & Rescue Boat, Certificate & Documentation - Crew Certificates, 1000, Missing, 11106, Fast Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 11118, Lifejackets Incl.Provision And Disposition, Life Saving Appliances, 1011, Not As Required, 04108, Muster List, Emergency Systems, 1179, Not Updated, 15150, ISM, ISM, 1011, Not As Required |
| 23 Jun 2023 | Ancona | No | 0 |
| 09 May 2023 | Bari | No | 1304108, Muster List, Emergency Systems, 1031, Incomplete, 10138, BNWAS, Safety Of Navigation, 1075, Inadequate2122, Openings To Cargo Area, Doors, ... Scuttles, Structural Conditions, 1011, Not As Required2105, Steering Gear, Structural Conditions, 1086, Not Properly Maintained, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1075, Inadequate4103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1082, Inoperative, 1842Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18327, Ventilation (Working Spaces), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 102Dirty Filters, 18499, Other (Health Protection, Medical Care), Labour Conditions - Health Protection, Medical Care, Social Security, 1238, Other, 1515ISM, ISM, 1011, Not As Required7125, Evaluation Of Crew Performance (Fire Drills), Fire Safety, 1213, Lack Of Information7105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 110Malfunctioning7109, Fixed Fire Extinguishing Installation, Fire Safety, 100Missing, |
| 10 Mar 2023 | Ancona | No | 903105, Covers (Hatchway-, Portable-, Tarpaulins, Etc.), Water/Weathertight Conditions, 1011, Not As Required, 04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1036, Insufficient, 04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1036, Insufficient, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 07115, Fire-Dampers, Fire Safety, 1011, Not As Required, 07117, Jacketed High Pressure Lines And Oil Leakage Alarm, Fire Safety, 1011, Not As Required, 02122, Openings To Cargo Area, Doors, ... Scuttles, Structural Conditions, 1011, Not As Required, 15150, ISM, ISM, 1011, Not As Required |
| 29 Aug 2022 | Ancona | No | 818414, Protection Machines/Parts, Labour Conditions - Health Protection, Medical Care, Social Security, 1033, Missing Equipment, 18420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 11118, Lifejackets Incl.Provision And Disposition, Life Saving Appliances, 1011, Not As Required, 11102, Lifeboat Inventory, Life Saving Appliances, 1000, Missing, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1082, Inoperative, 07111, Personal Equipment For Fire Safety, Fire Safety, 1086, Not Properly Maintained, 18408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1027, Unsafe, 15150, ISM, ISM, 1011, Not As Required, |
| 18 Jun 2022 | Bari | No | 0 |
| 07 Apr 2022 | Ancona | No | 707108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1045, Not Properly Stowed, 11112, Launching Arrangements For Survival Craft, Life Saving Appliances, 1086, Not Properly Maintained, 07115, Fire-Dampers, Fire Safety, 1011, Not As Required, 18416, Ropes And Wires, Labour Conditions - Health Protection, Medical Care, Social Security, 1086, Not Properly Maintained, 04103, Emergency, Lighting,Batteries And Switches, Emergency Systems, 1086, Not Properly Maintained, 07109, Fixed Fire Extinguishing Installation, Fire Safety, 1011, Not As Required, 15150, ISM, ISM, 1011, Not As Required, |
| 08 Jun 2021 | Ancona | No | 309232, Cleanliness Of Engine Room, Living And Working Conditions - Working Conditions, 1036, Insufficient, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1100, Malfunctioning, 10127, Voyage Or Passage Plan, Safety Of Navigation, 1031 |