BoatDB
Vessel

MD MIRANDA

IMO 9198290
TankerBuilt 1999Active
28,246
Gross tonnageA measure of the vessel's total internal volume (not its weight).
46,408
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
1999
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9198290
MMSI
629009783
Call sign
C5J885
Flag
GM
Type
Oil Or Chemical Tanker
Length (LOA)
182.94 m
Beam
32.2 m
Home port

Ownership

Beneficial owner
Unknown· Unknown
Operator
Unknown· Unknown
Technical manager
Unknown
Commercial manager
Unknown
Class society
IR
Design DWT
46,408 t
Flag
Gambia
Built
1999

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Sold
    $18.3M
  4. Casualty · Mechanical Fault
    Tanker suffered mechanical failure at Taman, Russia. Crew carried out repairs an
  5. Sold
    $6.8M · to Seven Islands Shipping Co. Pvt Ltd
  6. Built

Engine

main engine & propulsion
Engine builder
HD Hyundai Heavy Industries
Designer
B&W
Designation
6S50MC-MKVI
Power (MCO)
7,466 kW
RPM
117
Propulsion
MO
Trading category
Live

Surveys & certificates

dry dock & statutory certificates
Last dry dock
31 Oct 2027
Special survey
31 Oct 2029
IOPP issued
18 Dec 2024
IOPP expires
31 Oct 2029

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
07 Apr 2026NovorossiyskNo61 CERTIFICATE AND DOCUMENTATION - SHIP CERTIFICATES (Safety Management Certificate (SMC/ISM Code)) Rectify Deficiency Before Departure Deficiency Rectified 2 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) Rectify Deficiency Within 14 Days 3 PROPULSION AND AUXILIARY MACHINERY (Operation Of Machinery) Rectify Deficiency Within 14 Days 4 PROPULSION AND AUXILIARY MACHINERY (Operation Of Machinery) Rectify Deficiency Within 14 Days 5 PROPULSION AND AUXILIARY MACHINERY (Other (Machinery)) Rectify Deficiency Within 14 Days 6 LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Ventilation (Working Spaces)) Rectify Deficiency Before Departure Deficiency Rectified
09 Apr 2025NovorossiyskNo71 POLLUTION PREVENTION - MARPOL ANNEX V (Garbage Shipboard Handling) (30.12.2024) Rectify Deficiency At Next Port Deficiency Rectified 2 STRUCTURAL CONDITIONS (Ballast, Fuel And Other Tanks) Rectify Deficiency Before Departure Deficiency Rectified 3 DANGEROUS GOODS (Special Requirement) Rectify Deficiency Before Departure Deficiency Rectified 4 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) Rectify Deficiency Before Departure Deficiency Rectified 5 FIRE SAFETY (Ready Availability Of Fire Fighting Equipment) Rectify Deficiency Before Departure Deficiency Rectified 6 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) Rectify Deficiency Before Departure Deficiency Rectified 7 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) Rectify Deficiency Before Departure Deficiency Rectified
30 Dec 2024TuapseNo41 ISM (ISM) (07.06.2024) Corrective Action Taken On The ISM System By The Company Is Required Within 3 Months Deficiency Rectified 2 POLLUTION PREVENTION - MARPOL ANNEX V (Garbage Shipboard Handling) Rectify Deficiency At Next Port 3 LIVING AND WOR
29 Dec 2024TuapseNo4ISM (ISM) ; POLLUTION PREVENTION - MARPOL ANNEX V (Garbage Shipboard Handling) ; LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Other (Accident Prevention)) ; FIRE SAFETY (Other (Fire Safety))
07 Jun 2024TuapseNo17POLLUTION PREVENTION - BALLAST WATER (Ballast Water Record Book); FIRE SAFETY (Fire-Dampers) ; POLLUTION PREVENTION - MARPOL ANNEX I (Retention Of Oil On Board) ; STRUCTURAL CONDITIONS (Decks - Corrosion); FIRE SAFETY (Ventilation ); CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Log-Books/Compulsory Entries) ; FIRE SAFETY (Personal Equipment For Fire Safety) ; LABOUR CONDITIONS-ACCOMMODATION, RECREATIONAL FACILITIES, FOOD AND CATERING (Cleanliness) ; ISM (ISM) ; LIFE SAVING APPLIANCES (Lifebuoys Incl. Provision And Disposition) ; LIFE SAVING APPLIANCES (Maintenance And Inspections) ; LIFE SAVING APPLIANCES (Lifeboats) ; FIRE SAFETY (Fire Pumps And Its Pipes) ; FIRE SAFETY (Other (Fire Safety)) ; POLLUTION PREVENTION - MARPOL ANNEX IV (Sewage Treatment Plant) ; FIRE SAFETY (Other (Fire Safety); LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Lighting (Working Spaces))
28 Mar 2024TamanNo17LIFE SAVING APPLIANCES (Lifeboats) ; EMERGENCY SYSTEMS (Emergency Fire Pump And Its Pipes) ; FIRE SAFETY (Fire Fighting Equipment And Appliances); WATER/WEATHERTIGHT CONDITIONS (Doors ) ; FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) ; LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Winches & Capstans) ; PROPULSION AND AUXILIARY MACHINERY (Operation Of Machinery); EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) ; WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings); POLLUTION PREVENTION - BALLAST WATER (Ballast Water Record Book); FIRE SAFETY (Fire-Dampers) ; LIFE SAVING APPLIANCES (Maintenance And Inspections) ; POLLUTION PREVENTION - MARPOL ANNEX I (Retention Of Oil On Board) ; EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) ; LIFE SAVING APPLIANCES (Maintenance Of Life Saving Appliances); FIRE SAFETY (Ready Availability Of Fire Fighting Equipment); STRUCTURAL CONDITIONS (Decks - Corrosion)
16 Mar 2024La SkhiraNo3Emergency Systems 04114 - Emergency Source Of Power - Emergency Generator Not Properly Maintained Safety Of Navigation 10110 - Signalling Lamp Inoperative Safety Of Navigation 10109 - Lights, Shapes, Sound-Signals Not As Re
15 Mar 2024La SkhiraNo3Emergency Systems - Emergency Source Of Power - Emergency Generator Not Properly Maintained ; Safety Of Navigation - Signalling Lamp ; Safety Of Navigation - Lights, Shapes, Sound-Signals Not As Required
03 Jan 2024TamanYes91 LIFE SAVING APPLIANCES (Lifeboats) Detainable Deficiency Other (Specify) 2 EMERGENCY SYSTEMS (Emergency Fire Pump And Its Pipes) Detainable Deficiency Other (Specify) 3 FIRE SAFETY (Fire Fighting Equipment And Appliances) Rectify Deficiency Before Departure Other (Specify) 4 WATER/WEATHERTIGHT CONDITIONS (Doors ) Rectify Deficiency Before Departure Other (Specify) 5 FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) Rectify Deficiency Before Departure Other (Specify) 6 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Winches & Capstans) Rectify Deficiency Before Departure Other (Specify) 7 PROPULSION AND AUXILIARY MACHINERY (Operation Of Machinery) Rectify Deficiency Before Departure Other (Specify) 8 EMERGENCY SYSTEMS (Emergency, Lighting,Batteries And Switches) Rectify Deficiency Before Departure Other (Specify) 9 WATER/WEATHERTIGHT CONDITIONS (Ventilators, Air Pipes, Casings) Rectify Deficiency Before Departure Other (Specify)
19 Jul 2023TuapseNo51 CERTIFICATE AND DOCUMENTATION - DOCUMENTS (Fire Control Plan - All) Rectify Deficiency Before Departure Deficiency Rectified 2 LIFE SAVING APPLIANCES (Lifeboats) Rectify Deficiency Before Departure Deficiency Rectified 3 LABOUR CONDITIONS-HEALTH PROTECTION, MEDICAL CARE,SOCIAL SECURITY (Medical Equipment, Medical Chest, Medical Guide) Rectify Deficiency Before Departure Deficiency Rectified 4 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Ropes And Wires) Rectify Deficiency Before Departure Deficiency Rectified 5 STRUCTURAL CONDITIONS (Steering Gear ) Rectify Deficiency Before Departure Deficiency Rectified

Casualties

DateTypeDetails
04 Jan 2024Mechanical FaultTanker suffered mechanical failure at Taman, Russia. Crew carried out repairs and departure permission was give on 13 January.

Sale & demolition history

reported transactions & recycling
DateEventPriceReported sale price in US$ millions.Buyer
16 Apr 2025 Reported Sold$18.3MUnknown
12 Mar 2019 Reported SoldNote: Deepwell. Imo II/III. SS due 10/19.$6.8MSeven Islands Shipping Co. Pvt Ltd