| Date | Port | Detained | Deficiencies |
|---|---|---|---|
| 15 May 2026 | Livorno | No | 4Other Labour Conditions - Health Protection, Medical Care, Social Security 18408 - Electrical Not As Required Certificate & Documentation - Documents 01314 - SOPEP Entries Missing Pollution Prevention - Marpol Annex V 14503 - Garbage Management Plan Not As Required |
| 15 May 2026 | Livorno |
| No |
| 318408, Electrical, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required,01314, SOPEP, Certificate & Documentation - Documents, 1002, Entries Missing,14503, Garbage Management Plan, Pollution Prevention - Marpol Annex V, 1011, Not As Required |
| 27 Mar 2026 | Busan | No | 31 11108 LIFE SAVING APPLIANCES (Inflatable Liferafts) No 2 09298 LIVING AND WORKING CONDITIONS - WORKING CONDITIONS (Other (Accident Prevention)) No 3 04104 EMERGENCY SYSTEMS (Low Level Lighting In Corridors) |
| 03 Mar 2026 | Sydney | No | 21 05118 RADIO COMMUNICATIONS (Operation Of GMDSS Equipment) No 2 05110 RADIO COMMUNICATIONS (Facilities For Reception Of Marine Safety Inform.) No |
| 02 Feb 2026 | San Diego | No | 1System: 07 - Fire Safety Sub-System: N/A - No Subsystem Component: 07123 - Operation Of Fire Protection Systems Cause: Action: 10 - Deficiency Rectified Action Code: C - To The Satisfaction Of The Coast Guard Description Of Deficiency: Fire Protection System Are Fight-Fighting System And Appliances Shall Be Maintained Ready For Use. Two Manual Call Points (214076 And 214078) Were Found Inoperable In The Theatre Space. 74 SOLAS (2020 Cons.) II-2/14.1.1 Due Date: 2/3/2026 12:00:00 AM Deficiency Resolved? Yes Resolved Date: 2/3/2026 12:00:00 AM Resolution Description: Crew Fixed Manual Call Points. CG Examiner Verified. |
| 28 Jun 2025 | Barcelona | No | 0 |
| 26 Mar 2025 | Fremantle | No | 11 04114 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) (20.03.2025) No |
| 26 Mar 2025 | Fremantle | No | 41 07105 Fire Doors/Openings In Fire-Resisting Divisions 2 07115 Fire-Dampers 3 04114 Emergency Source Of Power - Emergency Generator 4 13199 Other (Machinery) |
| 20 Mar 2025 | Port Adelaide | No | 407105 FIRE SAFETY (Fire Doors/Openings In Fire-Resisting Divisions) 07115 FIRE SAFETY (Fire-Dampers) 04114 EMERGENCY SYSTEMS (Emergency Source Of Power - Emergency Generator) 13199 PROPULSION AND AUXILIARY MACHINERY (Other (Machinery)) |
| 19 Mar 2025 | Valparaiso | No | 1PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (10.02.2025) |
| 18 Feb 2025 | Valparaiso | No | 21 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (10.02.2025) No 2 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (10.02.2025) No |
| 10 Feb 2025 | Valparaiso | No | 21 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (10.02.2025) No 2 13102 PROPULSION AND AUXILIARY MACHINERY (Auxiliary Engine) (10.02.2025) No |
| 24 Dec 2024 | Valletta | No | 0 |
| 13 May 2024 | Miami Beach, Florida | No | 0 |
| 17 Nov 2023 | San Juan, Puerto Rico | No | 3System: 11 - Life Saving Appliances Sub-System: N/A - No Subsystem Cause: Description Of Deficiency: Before The Ship Leaves Port And At All Times During The Voyage, All Life Saving Appliances Shall Be In Working Order And Ready For Immediate Use. Descent |
| 30 Apr 2023 | Civitavecchia | No | 0 |
| 17 Mar 2023 | Sydney, Nsw | No | 11 11104 LIFE SAVING APPLIANCES (Rescue Boats) No |
| 09 Feb 2023 | Valparaiso | No | 0 |
| 16 Nov 2022 | Lanzarote | No | 0 |
| 16 Nov 2021 | Southampton | No | 707105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 11131, On Board Training And Instructions, Life Saving Appliances, 1011, Not As Required, 18417, Anchoring Devices, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 18418, Winches & Capstans, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 11112, Launching Arrangements For Survival Craft, Life Saving Appliances, 1011, Not As Required, 11104, Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 11128, Line-Throwing Appliance, Life Saving Appliances, 1082, Inoperative, |