BoatDB
Vessel

MYS FLORA

IMO 9433286
SanctionedCargoBuilt 2009Active

Sanctioned vessel

On the OFAC Specially Designated Nationals (SDN) list — 1 listing.

RUSSIA-EO14024OFAC SDN
Secondary sanctions risk: See Section 11 of Executive Order 14024.; Vessel Registration Identification IMO 9433286; Linked To: EKO SHIPPING LIMITED LIABILITY COMPANY.

Source: US Treasury OFAC SDN list. Verify against the official source before relying on this for compliance.

9,627
Gross tonnageA measure of the vessel's total internal volume (not its weight).
12,729
DeadweightMaximum weight of cargo, fuel and stores the vessel can carry (tonnes).
658
TEU capacityMaximum number of standard 20-ft containers the vessel can carry.
2009
Year built

Live position & voyage

LIVE
Loading position…

Particulars

IMO
9433286
MMSI
273295260
Call sign
UBHW2
Flag
RU
Type
General Cargo
Length (LOA)
138.54 m
Beam
21 m
Home port

Ownership

Beneficial owner
Operator
Eco Shipping· Russia
Technical manager
Eco Shipping
Commercial manager
Eco Shipping
Class society
NK
Design DWT
12,776 t
Flag
Antigua And Barbuda
Built
2009

Timeline

key events over the vessel's life
  1. Special survey
  2. Dry dock
  3. Built

Surveys & certificates

dry dock & statutory certificates
Last dry dock
19 Sep 2027
Special survey
19 Sep 2029
IOPP issued
30 Aug 2024
IOPP expires
19 Sep 2029

Shipments carried

recent bills of lading
No shipment records.

Inspections

recent port state control
DatePortDetainedDeficiencies
22 Dec 2021HamburgYes4407106, Fire Detection And Alarm System, Fire Safety, 1082, Inoperative, 05118, Operation Of GMDSS Equipment, Radio Communications, 1208, Lack Of Familiarity, 15150, ISM, ISM, 1011, Not As Required, 10127, Voyage Or Passage Plan, Safety Of Navigation, 1213, Lack Of Information, 10109, Lights, Shapes, Sound-Signals, Safety Of Navigation, 1082, Inoperative, 10135, Monitoring Of Voyage Or Passage Plan, Safety Of Navigation, 1011, Not As Required, 02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required, 07108, Ready Availability Of Fire Fighting Equipment, Fire Safety, 1082, Inoperative, 11103, Stowage And Provision Of Lifeboats, Life Saving Appliances, 1011, Not As Required, 02101, Closing Devices/Watertight Doors, Structural Conditions, 1011, Not As Required, 11113, Launching Arrangements For Rescue Boats, Life Saving Appliances, 1086, Not Properly Maintained, 14801, Ballast Water Management Plan, Pollution Prevention - Ballast Water, 1177, Incorrect, 07120, Means Of Escape, Fire Safety, 1011, Not As Required, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 02107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1000, Missing, 02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required, 18420, Cleanliness Of Engine Room, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 13102, Auxiliary Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 02101, Closing Devices/Watertight Doors, Structural Conditions, 1118, Not Properly Secured, 13106, Insulation Wetted Through (Oil), Propulsion And Auxiliary Machinery, 1026, Damaged, 18410, Gas Instruments, Labour Conditions - Health Protection, Medical Care, Social Security, 1082, Inoperative, 18414, Protection Machines/Parts, Labour Conditions - Health Protection, Medical Care, Social Security, 1011, Not As Required, 02108, Electrical Installations In General, Structural Conditions, 1011, Not As Required, 13103, Gauges,Thermometers, Etc, Propulsion And Auxiliary Machinery, 1086, Not Properly Maintained, 02107, Ballast, Fuel And Other Tanks, Structural Conditions, 1011, Not As Required, 08108, UMS - Alarms, Alarms, 1075, Inadequate, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 14199, Other (MARPOL Annex I), Pollution Prevention - Marpol Annex I, 1026, Damaged, 04121, Crew Familiarization With Emergency Systems, Emergency Systems, 1011, Not As Required, 08107, Machinery Controls Alarm, Alarms, 1100, Malfunctioning, 18305, Hospital Accomodation (Sickbay), Labour Conditions - Accommodation, Recreational Facilities, Food And Catering, 1011, Not As Required, 07113, Fire Pumps And Its Pipes, Fire Safety, 1011, Not As Required, 13101, Propulsion Main Engine, Propulsion And Auxiliary Machinery, 1011, Not As Required, 07106, Fire Detection And Alarm System, Fire Safety, 1011, Not As Required, 03112, Scuppers, Inlets And Discharges, Water/Weathertight Conditions, 1011, Not As Required, 14402, Sewage Treatment Plant, Pollution Prevention - Marpol Annex IV, 1011, Not As Required, 04114, Emergency Source Of Power - Emergency Generator, Emergency Systems, 1011, Not As Required, 10128, Navigation Bridge Visibility, Safety Of Navigation, 1011, Not As Required, 07105, Fire Doors/Openings In Fire-Resisting Divisions, Fire Safety, 1011, Not As Required, 07106, Fire Detection And Alarm System, Fire Safety, 1082, Inoperative, 07115, Fire-Dampers, Fire Safety, 1011, Not As Required, 14121, Suspected Of Discharge Violation, Pollution Prevention - Marpol Annex I, 1011, Not As Required, 07116, Ventilation, Fire Safety, 1011, Not As Required